Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathtBehQCStation.m
More file actions
116 lines (97 loc) · 5.07 KB
/
Copy pathtBehQCStation.m
File metadata and controls
116 lines (97 loc) · 5.07 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
classdef tBehQCStation < sltest.TestCase
% tBehQCStation - Behavioral tests for the BehQCStation component model.
%
% Ports (fixed simulation order):
% Inports: inflow_bps, enable
% Outports: passflow_bps, rejectflow_bps, calibrating
properties (Constant)
ModelName = 'BehQCStation'
RejectFrac = 0.02 % must match model argument default
end
methods (Test)
function passRejectSplitRatio(testCase)
% With calibration pushed far out, the station should stay in
% Inspecting mode and split flow by (1-RejectFrac)/RejectFrac.
stopTime = 2000;
inflowBps = 0.02;
extInput = sprintf('[0 %g 1; %g %g 1]', inflowBps, stopTime, inflowBps);
out = testCase.runModel(extInput, stopTime, 'CalibPeriod_s', 1e6);
time = out.yout{1}.Values.Time;
passflow = out.yout{1}.Values.Data;
rejectflow = out.yout{2}.Values.Data;
tailIdx = time >= (stopTime - 500);
meanPass = mean(passflow(tailIdx));
meanReject = mean(rejectflow(tailIdx));
testCase.verifyEqual(meanPass / (meanPass + meanReject), 1 - tBehQCStation.RejectFrac, 'RelTol', 0.01);
testCase.verifyEqual(meanPass + meanReject, inflowBps, 'RelTol', 0.02);
end
function calibrationOutageBlocksFlow(testCase)
% A short calibration period/time should trigger a visible
% calibration outage window where passflow collapses.
stopTime = 800;
calibPeriodS = 300;
calibTimeS = 100;
extInput = sprintf('[0 0.02 1; %g 0.02 1]', stopTime);
out = testCase.runModel(extInput, stopTime, 'CalibPeriod_s', calibPeriodS, 'CalibTime_s', calibTimeS);
time = out.yout{1}.Values.Time;
passflow = out.yout{1}.Values.Data;
calibrating = out.yout{3}.Values.Data;
testCase.verifyEqual(max(calibrating), 1, 'AbsTol', 1e-9);
outageIdx = time >= 310 & time <= 390;
nominalPass = 0.02 * (1 - tBehQCStation.RejectFrac);
testCase.verifyLessThan(mean(passflow(outageIdx)), 0.10 * nominalPass);
end
function contaminationDetectionSplit(testCase)
% SR-GS-007 component-level: contamination applies to the
% quality-passed stream, detected mass moves to rejects at
% DetectSensitivity, escaped mass ships with the passed flow.
stopTime = 2000;
inflowBps = 0.02;
inc = 0.05; sens = 0.995;
extInput = sprintf('[0 %g 1; %g %g 1]', inflowBps, stopTime, inflowBps);
out = testCase.runModel(extInput, stopTime, 'CalibPeriod_s', 1e6, ...
'ContamIncidence', inc, 'DetectSensitivity', sens);
time = out.yout{1}.Values.Time;
tailIdx = time >= (stopTime - 500);
passOut = mean(out.yout{1}.Values.Data(tailIdx));
rejOut = mean(out.yout{2}.Values.Data(tailIdx));
det = mean(out.yout{4}.Values.Data(tailIdx));
esc = mean(out.yout{5}.Values.Data(tailIdx));
passQ = inflowBps * (1 - tBehQCStation.RejectFrac);
contam = passQ * inc;
testCase.verifyEqual(det, contam * sens, 'RelTol', 0.01, 'detected split');
testCase.verifyEqual(esc, contam * (1 - sens), 'RelTol', 0.01, 'escaped split');
testCase.verifyEqual(det / (det + esc), sens, 'RelTol', 1e-6, 'sensitivity exact');
testCase.verifyEqual(passOut, passQ - det, 'RelTol', 0.01, 'pass stream loses detected');
testCase.verifyEqual(rejOut, inflowBps * tBehQCStation.RejectFrac + det, ...
'RelTol', 0.01, 'reject stream gains detected');
% conservation: nothing created or destroyed by detection
testCase.verifyEqual(passOut + rejOut, inflowBps, 'RelTol', 0.02, 'mass conservation');
end
function disabledStationBlocksFlow(testCase)
% enable<0.5 should stop the pass stream entirely.
stopTime = 200;
extInput = sprintf('[0 0.02 0; %g 0.02 0]', stopTime);
out = testCase.runModel(extInput, stopTime);
passflow = out.yout{1}.Values.Data;
testCase.verifyEqual(passflow(end), 0, 'AbsTol', 1e-6);
end
end
methods (Static, Access = private)
function out = runModel(extInput, stopTime, varargin)
% Build and run a SimulationInput for BehQCStation.
% varargin is a name/value list of model-argument overrides.
in = Simulink.SimulationInput(tBehQCStation.ModelName);
in = in.setModelParameter('LoadExternalInput', 'on', ...
'ExternalInput', extInput, ...
'StopTime', num2str(stopTime), ...
'SaveOutput', 'on', ...
'SaveFormat', 'Dataset');
for k = 1:2:numel(varargin)
in = in.setVariable(varargin{k}, varargin{k+1}, 'Workspace', tBehQCStation.ModelName);
end
simOut = sim(in);
out = simOut;
end
end
end