Hardware Installation

Configuring The Heidelberg Wallbox

  1. Disconnect the wallbox from the power supply.
  2. Open the housing.
  3. Set DIP switch S4 pin 4 to 1 (this sets the Modbus ID to 1).
  4. Set DIP switch S6 pin 2 to 1 (this enables the 120 Ohm termination).

Connecting the Hardware Components

The hardware connections are very simple:

  • ESP32's GND to MAX485-board GND
  • ESP32's 3.3 V to MAX485-board VCC
  • ESP32 pin 18 to MAX485-board RO pin
  • ESP32 pin 19 to MAX485-board DI pin
  • ESP32 pin 21 to MAX485-board DE+RE pins
  • MAX485-board A terminal to Heidelberg wallbox A terminal
  • MAX485-board B terminal to Heidelberg wallbox B terminal

Hardware connections