Open
Description
Hardware
Heltec V3
Connection Type
Serial
Firmware Version
2.4.2.5b45303
Description
I am connected to my device via NodeJS serial and just reading the logs with concurrentLogOutput
set to true
. There is an unhandled payload variant.
It looks a lot uglier when you turn off concurrentLogOutput
and it seems as the unhandled payload is considered "padding" from the TransformStream
.
Relevant console output
02:48:41:722 WARN [iMeshDevice:SerialConnection] HandleFromRadio ⚠️ Unhandled payload variant: undefined
DeviceDebugLog: Uint8Array(203) [
27, 91, 51, 50, 109, 0, 73, 78, 70, 79, 32, 32,
27, 91, 48, 109, 124, 32, 63, 63, 58, 63, 63, 58,
63, 63, 32, 50, 50, 56, 53, 32, 91, 83, 101, 114,
105, 97, 108, 67, 111, 110, 115, 111, 108, 101, 93, 32,
27, 91, 51, 50, 109, 0, 103, 101, 116, 70, 114, 111,
109, 82, 97, 100, 105, 111, 61, 83, 84, 65, 84, 69,
95, 83, 69, 78, 68, 95, 70, 73, 76, 69, 77, 65,
78, 73, 70, 69, 83, 84, 13, 10, 27, 91, 48, 109,
0, 27, 91, 51,
... 103 more items
]
FromRadio: FromRadio {
id: 0,
payloadVariant: { case: undefined },
[Symbol(@bufbuild/protobuf/unknown-fields)]: [
{
no: 15,
wireType: 2,
data: <Buffer 20 0a 1b 2f 73 74 61 74 69 63 2f 73 69 74 65 2e 77 65 62 6d 61 6e 69 66 65 73 74 2e 67 7a 10 c5 01>
}
]
}