Miscellaneous additions to the Megatec protocol variants #58

Open
@dvdesolve

Description

@dvdesolve

I want to add some extra info about Megatec protocol. That's a partial translation of this web page - some obvious and well-known parts are omitted, as well as dubious points. Also some info obtained from RS232 sniffering is added too. NB: not all UPSes are capable to answer/consume these commands!

EDIT: for Q2, Q6 and WA commands see update in this comment

Command Description
AR?, AR0, AR1 Querying/disabling/enabling auto power-on feature (known as auto restart for some Ippon UPSes). Enabled by default (AR1). If option is off (AR0) then UPS will stay powered off even after mains return and should be switched on manually by using power button
AT?, AT0, AT1 Querying/disabling/enabling auto test feature
BL?, BL Battery level (in percents), usually represented as 3-digit number with explicit 0 at the beginning
BPS Query bypass status. Typical answer: (230.4 000.0 000.0 49.9. Fields 1--3 should be L1-N, L2-N and L3-N input bypass voltages, field 4 is input bypass frequency
EB?, EBnn Query/set number of external battery packs
EF? Acceptable frequency deviations for HE/ECO mode (in percents)
EV? Acceptable voltage deviations for HE/ECO mode (in percents)
FW? Firmware version
GR?, GR0, GR1 Query/disable/enable green mode (WinPower provides Energy Saving feature to control this mode). Some UPSes switch itslef off after 5 mins without load
IP?, IPN, IPW, IPG Query/set acceptable deviations for different modes: normal (IPN), wide (IPW), generator (IPG). Corresponding LEDs will be toggled for Smart Winner UPS
M Query protocol type: the answer is usually P, T, V, C and some others
Q2 Query UPS status (analogous to Q1). Typical answer: (226.6 224.3 228.0 226.6 229.9 000.0 000.0 000 000 000 49.9 327.6 18.0 00000000 999.24 100 02 00 00 00 00 00000000 11. As far as I was able to decipher this first three fields correspond to the L1-N, L2-N and L3-N input voltages, fifth field is output voltage (3/1 Ippon UPS was tested though, may be fields 5--7 correspond to the L1-N, L2-N and L3-N output voltages) eleventh field seems to be frequency (don't know, input or output), twelfth field is battery voltage, thirteenth field is temperature, 15th field may be estimated runtime (in minutes?) and 16th field is battery level (in percents, with leading zero). However, I'm not sure about fields 4, 6--11, 14--23
Q4 Yet another UPS status query. Typical answer: (MMM.M ???.? ???.? NNN.N PPP.P ??? QQQ RR.R ??? ??? SS.S TT.T flags. Some flags: E - test in progress, A - mains fault, on battery, C - bypass/AVR mode
Q6 Query UPS status, especially useful for three phase models. Typical answer: (227.0 225.6 230.0 50.0 229.9 000.0 000.0 49.9 007 000 000 327.8 000.0 23.0 06932 100 32 00000000 00000000 11. Fields 1--3 are L1-N, L2-N and L3-N input voltages, field 4 is input frequency, fields 5--7 should be L1-N, L2-N and L3-N output voltages, field 8 is output frequency, field 9 is load (in percents, with leading zero), field 12 is battery voltage, field 14 is temperature, field 15 is estimated runtime (in seconds), field 16 is battery level (in percents, with leading zero)
QBL Query battery stats. Typical answer: (026.5 02 01 068 255. Field 1 is battery voltage, field 2 is a number of batteries connected in series, field 3 is a number of batteries connected in parallel, field 4 is battery level (in percents, with leading zero), field 5 is estimated runtime (in minutes?)
QI Query serial number info
QLDL Query min and max load stats
QMD Query nominal UPS stats such as power capacity, number of batteries etc
QMF Query manufacturer info
QMOD Query current status code
QOF Query output frequency info
QP Query acceptable bypass limits. Typical answer: (45.0 55.0 176 264 EpbraDokc. Fields 1 and 2 are low and high limits for input bypass frequency, fields 3 and 4 are the same but for the voltage, field 5 is flags
QRI Yet another query for nominal UPS stats
QVFW Yet another firmware version query
SASV07? Query for serial number. Typical answer starts with GASV07D string
TC? Query for temperature
V Query for AVR mode settings. Typical answer: 165 200 220 240 275. Field 1 is low limit for battery transition, field 2 is low limit for engaging AVR boost, field 3 is nominal voltage, field 4 is high limit for engaging AVR buck, field 5 is high limit for battery transition
V? Query for output voltage mode
V220, V230, V240 Set output voltage mode (corresponding LED may be toggled)
WH Query for model info and nominal specs. Typical answer: (00 00.00 00.00 INN3T20K 2 3/1 6 230 50.00 024 02.00 005.00 015.00 005 00 40 110 276 45.00 55.00. Seems to be model code (field 4), topology (field 6), nominal voltage (field 8) and frequency (field 9), number of batteries (field 10)
WA Query for power/load stats. Typical answer: (001.4 000.0 000.0 001.4 000.0 000.0 001.4 001.4 006.5 000.0 000.0 007 00000000. Fields 1 and 7 seems to be real power measurements on output while fields 4 and 8 - the full one. This example a bit clumsy because in that case cos(phi) was about 1, but in another measurements I was able to get different readings. Not sure why these fields are in pairs (m. b. rolling average?). Field 9 is a current (amps), field 12 - load (percents)