Skip to content

Commit 16e8ca0

Browse files
Add example 6
1 parent e4c86c6 commit 16e8ca0

File tree

3 files changed

+32
-0
lines changed

3 files changed

+32
-0
lines changed
Lines changed: 12 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,12 @@
1+
{
2+
"Coordsystem": {
3+
"hand-coordsystem":{
4+
"EMGCoordinateUnits": "percent",
5+
"EMGCoordinateSystemDescription": "X: RSP → USP; Y: Dorsal → Palmar surface at the midpoint RSP-USP; Z: MCP → midpoint RSP-USP; Ulnar Styloid Process (USP), Radial Styloid Process (RSP); Ulnar Styloid Process (USP);Third Metacarpophalangeal Joint (MCP): The knuckle of the middle finger"
6+
},
7+
"lower-leg-coordsystem":{
8+
"EMGCoordinateUnits": "percent",
9+
"EMGCoordinateSystemDescription": "X: FME → FLE; Y: Popliteal Fossa → Patellar Anterior Surface; Z: midpoint FME-FLE → Greater Trochanter; Femur Medial Epicondyle (FME); Femur Lateral Epicondyle (FLE); Patellar Anterior Surface; Back of the knee (Popliteal Fossa)"
10+
}
11+
}
12+
}
Lines changed: 3 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,3 @@
1+
name type units target_muscle interelectrode_distance placement loc_reference
2+
EMG1 emg V First Dorsal Interosseous 20 mm [0,0,40] hand-coordsystem
3+
EMG2 emg V Tibilias Anterior 20 mm [60,100,50] lower-leg-coordsystem
Lines changed: 17 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,17 @@
1+
{
2+
"EMGChannelCount":2,
3+
"EMGPlacementScheme":"The sEMG sensor was located on the belly of the muscle at a position distant from the innervation zones and the muscle tendon interface, following the recommendations of De Luca, 1997 and Saitou et al., 2000. For the sake of this example we will try to included the exact location of the electrodes in the channels.tsv file.",
4+
"EMGReference":"bipolar",
5+
"EMGGround":"n/a",
6+
"EMGElectrodeCount":4,
7+
"ElectrodeMaterial":"Ag/AgCl",
8+
"Manufacturer":"Delsys",
9+
"ManufacturersModelName":"Trigno DE via Delsys Bagnoly-8 amplifier",
10+
"AmpifierType":"Wired",
11+
"RecordingDuration":1.00,
12+
"SamplingFrequency":2000,
13+
"HardwareFilters":"loawpass at 450 Hz, Highpass at 0.15 Hz",
14+
"TaskDescription":"The movement artifacts were analyzed during limb perturbations on with EMG snesors attached to both lower and upper limbs",
15+
"TaskName":"mechPerturbations",
16+
"TriggerChannelCount":0
17+
}

0 commit comments

Comments
 (0)