Self-service: connected accounts

conductor's self-service has a "Connected accounts" page: for each target directory conductor-sync provisions to, a signed-in user sees their own account there and, when the target and its policy allow it, can activate it or set a new password. conductor-sync does the work on the user's explicit request, never from a schedule; conductor shows what conductor-sync reports and knows nothing specific to a target.

Google Workspace is the connector implemented. The protocol and the page are generic: a connector declares what it supports and conductor renders only that.

What a user can do

Action Effect
See the status not activated, active, suspended, waiting for the next sync run, or not available (with the reason), the account's address, and whether the sync created it or adopted it
Activate creates the account now (on-demand provisioning), with a password shown once or typed by the user
New password sets a new password on the user's own linked account: generated and shown once, or typed by the user

No password is stored anywhere: not in AD, not in conductor, not in conductor-sync's state, logs, journal or audit. Storing an initial password in an AD attribute was rejected: such attributes are readable by authenticated users by default and end up in plain text in backups and replication.

Capabilities of a connector

A connector that supports self-service implements an optional interface and declares its capabilities:

Capability Meaning
on_demand_create one account can be created on request, with the user's password
set_password a password can be set on an existing account
password_rules the target publishes its password rules (length, characters)
status one account can be read

conductor-sync raises the rules with the policy (password_min_length) and returns them with the status, so conductor can tell the user what a typed password must look like. The Google connector declares all four; its rules are 8 to 100 characters, printable ASCII, no leading or trailing space (a tenant's own password policy may require more: the Directory API then refuses the password and the user is told so).

Policy

[self_service] in the configuration file, or self_service in the settings edited through the management API (defaults travel as empty, and an empty value keeps the file's):

Key Default Values and effect
activation auto auto: the sync runs create accounts as before and activation is not offered. self-service: the sync runs create an account only for users who activated theirs; the others are shown in every plan as pending-activation warnings. Adoptions, updates and suspensions are not affected
password_reset created created: only accounts the sync created. created-and-adopted: also accounts that existed before the sync and were adopted, each only when an administrator approved its adoption (conductor-sync adopt approve). off: no password changes
chosen_password off allow: the user may type a password instead of a generated one
password_min_length 12 raises the connector's minimum (8 to 100)
max_per_user_hour 3 activations and password changes per user in any hour
max_per_target_hour 30 the same for all users of the target

Safety rules

  • The user is always the request's actor. conductor sends the signed-in user's SID; conductor-sync looks that user up in AD and never accepts a user named in the request.
  • Nothing is written in dry-run mode.
  • Eligibility is the sync scope: the user must be below the user bases, in an include group when there are any, in no exclude group, enabled (and not expired) and have a valid mapped address. The lookup of one user uses the same rules as a full read.
  • An activation runs the plan of a sync run with that user counted as activated, so the mapping, the address checks (duplicates, aliases, accounts owned by another source, existing unmanaged accounts) and the ownership marker are those of a run. Of that plan only the user's create is applied, with the user's memberships in groups that already exist; it is journaled as a run of its own (action activate, trigger self-service) and holds the run lock. An existing account with the address is never taken over by an activation: with adopt = "email" the next sync run adopts it, once an administrator approved that adoption.
  • A password is set only on the user's linked account that carries the sync's ownership marker for that user. Target administrators and the sync's own admin subject are always refused, whatever the policy; so are suspended accounts, users out of the scope or disabled, and adopted accounts unless password_reset = "created-and-adopted" and an administrator approved that adoption individually (an account adopted before approvals existed is refused until its adoption is confirmed with conductor-sync adopt approve).
  • The rate limits are kept in the state database, so they hold across restarts. Refusals do not count; every request that reaches the target does, successful or not.
  • conductor requires a session that passed a second factor, and asks for the password and a second factor again when the last one is older than a few minutes.

Passwords on the wire

Step What happens
Generated conductor-sync generates it (groups of four unambiguous letters and digits joined by hyphens, about 92 bits), sends it to the target once and returns it once in the API result; conductor keeps it in the session's memory until the user opens the page that shows it (once, not cached), then drops it
Typed conductor checks the confirmation and the length, holds it in the session's memory until the confirmation page is submitted (at most ten minutes), sends it to conductor-sync once; conductor-sync checks the rules and sends it to the target once
Google an activation is the same users.insert as a run's create; a reset is a users.patch whose body has only password and changePasswordAtNextLogin

changePasswordAtNextLogin is false for both. A run's create sets it to true because the random password is never shown to anyone; a self-service password is the user's own: only the user saw it (or chose it), so a forced change would only make them pick another one right away, and with single sign-on through conductor-idp it would interrupt the sign-in for nothing. The rest of the sync still never sends a password: updates, adoptions, suspensions and renames do not carry password or changePasswordAtNextLogin. The optional request log (CONDUCTOR_SYNC_REQUEST_LOG) records the field names of each request, so an operator can verify that only the activations and the resets carried a password.

Audit

  • conductor-sync's hash-chained audit log: api.account.activate and api.account.set_password (with the conductor actor), activate.start, activate.end and the create's own entry, self.set_password (address, target ID, whether the account was created or adopted, generated or typed), refusals and rate limits. Never a password.
  • The table selfservice_actions (state database) keeps who acted, when, on which account and with what result, for the rate limits.
  • conductor's audit log: self.account_activate and self.account_password with the previewed text (no password), and self.account_password_shown when the user opened the page with the generated password.

Management API

Operation Params Result
account.status AccountStatusParams (optional target) AccountStatus: one TargetAccount per target
account.activate AccountActivateParams: target, password mode (generate or chosen) and the typed password AccountActionResult: the account, the generated password (once), warnings
account.set_password AccountSetPasswordParams: the same AccountActionResult

A refusal is an error with code forbidden whose only detail is a reason code (out-of-scope, disabled, dry-run, adopted, admin, address-taken, existing-account, password-rules, target-refused, and others listed in syncapi), which conductor translates. The rate limits answer the code rate_limited. The operations were added without a protocol version change, like import.plan: they change no existing message, an older conductor never sends them and an older conductor-sync answers that they are not allowlisted. The new self_service settings are optional and absent while every value is the default.

Status from a run's point of view

  • With activation = "self-service", a plan lists every user waiting for activation as a pending-activation warning, not as an operation, so the plan's digest and limits do not depend on them.
  • An activation run is shown in the runs list with its single create; it is never applicable from there, and it does not supersede a plan under review (that plan has no operation for a user waiting for activation, so its digest is the same after the activation).
  • When an activated user's account is deleted outside the sync, the next run creates it again (with a random password and a change required, as any run's create); the user sets a new password in conductor.