I found new Parameter descriptions by tinkering with my
Alpha Innotec WZSV 62K3M Version V3.89.5

Channel 232: Heissgas (Celsius)
Channel 232: Liquefaction_Temperature (Celsius)
Channel 237: Freq_VD_Soll (Frequency)
Channel 238: Freq_VD_Max (Frequency)
Channel 239: VBO Sollwert (Kelvin)
Channel 240: VBO aktuell (Kelvin)
Channel 241: HUP (Percent)
Channel 242: HUP Sollwert (Kelvin)
Channel 243: HUP aktuell (Kelvin)
Channel 252 : T-HG max (Celsius)
Channel 258: RBE_Version
Channel 259 : Ausgang 9 (Bool) Output 9 on the Mainboard - used for cooling active Signal for Room thermostat switching between heating and cooling. If you have the Expansion board installed, this Signal comes then from Channel 140 descriped as FP3out.
Channel 260: Freigabe Kühlung (Seconds) enable Cooling