This describes the Z-Wave device ZW111, manufactured by AEON Labs with the thing type UID of aeon_zw111_02_003
.
This version of the device is limited to firmware versions above 2.3
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZW111 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Aeotec Nano Dimmer is a Z-Wave Smart Dimmer specifically used to enable Z-Wave command and control (on/off/dim) of any wall switches. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the unit’s operating status.
It can connect to 2 external manual switches to control the load ON/OFF independently. Its surface has a pin socket, which can be used for connecting to the touch panel, so you can also use the touch panel to control the Nano Dimmer.
The Nano Dimmer is also a security Z-Wave plus device and supports Over The Air (OTA) feature for the products firmware upgrade.
Including Nano Dimmer as a non-secure device:
If you want your Nano Dimmer as a non-secure device in your Z-Wave network, press the Action Button once on Nano Dimmer when you pair it to your gateway. If inclusion is successful, the green LED will be on for 2 seconds, and then return to a solid indication. If inclusion is unsuccessful, the red LED will be on for 2 seconds and then return to a colourful gradient.
Including Nano Dimmer as a secure device:
In order to take full advantage of the Nano Dimmer, you will want your Nano Dimmer as a security device that uses encrypted messages to communicate in your Z-wave network. A security enabled controller/ gateway (or Z-Wave Plus controller) is required.
- Set your Z-Wave Plus controller into pairing mode.
- Press the Action Button 2 times within 1 second on the Nano Dimmer, the blue LED (secure indication) will blink to indicate the Nano Dimmer is entering into secure pairing mode.
- If the Nano Dimmer has been successfully added to your Z-Wave network, its RGB LED will be solid. If the pairing was unsuccessful, the red LED will be on for 2 seconds and then remain a colourful gradient, repeat the instructions above from step 1.
Your Nano Dimmer can be removed from your Z-Wave network at any time. You’ll need to use your Z-Wave network’s main controller. To set your Z-Wave controller/gateway into removal mode, please refer to the respective section within your controller instruction manual.
- Set your Z-Wave controller into removal mode.
- Press the Action Button on the Nano Dimmer or toggle the external manual switch 2 times in fast succession.
- If the Nano Dimmer has been successfully removed from your Z-Wave network, its RGB LED will remain colourful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load), repeat the instructions above from step 1.
Reset your Nano Dimmer.
If at some stage, your primary controller is missing or inoperable, you may wish to reset all of your Nano Dimmer’s settings to their factory defaults. To do this, press and hold the Action Button for 20 seconds and then release it. Your Nano Dimmer will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colourful gradient status as a confirmation
The following table summarises the channels available for the ZW111 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Reset Meter [Deprecated] | meter_reset | meter_reset | Energy | Switch |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Alarm (heat) | alarm_heat | alarm_heat | Fire | Switch |
Clock Time Offset | time_offset | time_offset | Time | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Note: This channel is marked as deprecated so should not be used.
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a heat alarm is triggered.
The alarm_heat
channel is of type alarm_heat
and supports the Switch
item and is in the Fire
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
The following table provides a summary of the 48 configuration parameters available in the ZW111. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Current Overload Protection | Current Overload Protection |
4 | Overheat protection | Overheat protection |
20 | Configure the output status after re-power on it | Configure the output status after re-power on it |
21 | WallSwipe IR sensor | scene control functionality |
21 | WallSwipe IR sensor | scene control functionality for Left/Right wave |
21 | WallSwipe IR sensor | Wave Options |
21 | WallSwipe IR sensor | WallSwipe IR sensor |
64 | WallSwipe button color | WallSwipe button color |
65 | WallSwipe LED Up gesture action | WallSwipe LED Up gesture action |
66 | WallSwipe LED Down gesture action | WallSwipe LED Down gesture action |
67 | WallSwipe LED Left gesture action | WallSwipe LED Left gesture action |
68 | WallSwipe LED Right gesture action | WallSwipe LED Right gesture action |
69 | WallSwipe Night light | WallSwipe Night light |
71 | WallSwipe sensitivity | Set the sensitivity of WallSwipe |
80 | Group 1 notification | Set notification sent to associated nodes (group 1) |
81 | Group 3 notificaiton | Set notification sent to associated nodes (group 3) |
82 | Group 4 notificaiton | Set notification sent to associated nodes (group 4) |
83 | LED status | LED status |
84 | Time set for Night light mode | Time set for Night light mode |
85 | Set appointment 1 | Set appointment 1 |
86 | Set appointment 2 | Set appointment 2 |
90 | (En/dis)able 91 and 92 | Enables/disables parameter 91 and 92 |
91 | Set the threshold value of wattage | Threshold change in wattage (in terms of wattage) to induce an automatic report |
92 | Set the threshold value of percent power | Threshold change in wattage (in terms of percentage) |
100 | Reset 101-103 to default | Reset parameters 101-103 to default values |
101 | Set group 1 reports | To set which reports need to be sent in Report group 1 |
102 | Set group 2 reports | To set which reports need to be sent in Report group 2 |
103 | Set Group 3 Reports | To set which reports need to be sent in Report group 3 |
110 | Reset 111-113 to default | Reset parameters 111-113 to default values |
111 | Automatic report interval group 1 | Set the interval of automatic report for Report group 1 |
112 | Automatic report interval group 2 | Set the interval of automatic report for Report group 2 |
113 | Automatic report interval group 3 | Set the interval of automatic report for Report group 3 |
120 | Configure the external switch mode for S1 | Configure the external switch mode for S1 |
121 | Configure the external switch mode for S2 | Configure the external switch mode for S2 |
122 | Get the state of touch panel port | Get the state of touch panel port |
123 | Destination for switch S1 | Set the control destination for external switch S1 |
124 | Set the control destination for external switch S2 | Set the control destination for external switch S2 |
125 | Set the default dimming rate | The value range is 1 to 255 seconds |
128 | Get the current working mode | Get the current working mode |
129 | Set the dimming principle | Set the dimming principle |
130 | Type of load | To get what type of load the Dimmer is connected to. |
131 | Set the minimum brightness | Set the min brightness level that the load can reach to |
132 | Set the maximum brightness level | Set the max brightness level that the load can reach to |
247 | Working way for S1/S2 | Working way for S1/S2 |
248 | Function of S1/S2 | Function of S1/S2 |
249 | Set the recognition way of load | Set the recognition way of load |
252 | Lock/unlock configuration parameters | Lock/unlock configuration parameters |
255 | Reset the Nano Dimmer | Reset the Nano Dimmer |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Current Overload Protection
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | (Default) Enable |
The manufacturer defined default value is 1
((Default) Enable).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Overheat protection
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Disable |
1 | Enable |
The manufacturer defined default value is 0
((Default) Disable).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Configure the output status after re-power on it
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Last status |
1 | Always on |
2 | Always off |
The manufacturer defined default value is 0
((Default) Last status).
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
scene control functionality
The following option values may be configured -:
Value | Description |
---|---|
0 | disable the scene control |
1 | enable the scene control |
The manufacturer defined default value is 1
(enable the scene control).
This parameter has the configuration ID config_21_4_000000FF
and is of type INTEGER
.
scene control functionality for Left/Right wave
The following option values may be configured -:
Value | Description |
---|---|
0 | disable the scene control |
1 | enable the scene control |
The manufacturer defined default value is 0
(disable the scene control).
This parameter has the configuration ID config_21_4_0000FF00
and is of type INTEGER
.
Wave Options
The following option values may be configured -:
Value | Description |
---|---|
0 | Wave Option 1 is selected |
1 | Wave Option 2 is selected |
The manufacturer defined default value is 1
(Wave Option 2 is selected).
This parameter has the configuration ID config_21_4_00FF0000
and is of type INTEGER
.
WallSwipe IR sensor
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable the IR Sensor |
1 | Enable the IR Sensor |
The manufacturer defined default value is 0
(Disable the IR Sensor).
This parameter has the configuration ID config_21_4_0F000000
and is of type INTEGER
.
WallSwipe button color Set the button color of WallSwipe.
- Value 1= Level.
- Value 2= the color value of Red.
- Value 3= the color value of Green.
- Value 4= the color value of Blue.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 184549375
.
This parameter has the configuration ID config_64_4
and is of type INTEGER
.
WallSwipe LED Up gesture action Set the LED indication color of WallSwipe when the gesture action is UP.
- Value 1= Reserved.
- Value 2= the color value of Red.
- Value 3= the color value of Green.
- Value 4= the color value of Blue.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 855638015
.
This parameter has the configuration ID config_65_4
and is of type INTEGER
.
WallSwipe LED Down gesture action Set the LED indication color of WallSwipe when the gesture action is Down.
- Value 1= Level.
- Value 2= the color value of Red.
- Value 3= the color value of Green.
- Value 4= the color value of BlueThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 855638015
.
This parameter has the configuration ID config_66_4
and is of type INTEGER
.
WallSwipe LED Left gesture action Set the LED indication color of WallSwipe when the gesture action is Left.
- Value 1= Level.
- Value 2= the color value of Red.
- Value 3= the color value of Green.
- Value 4= the color value of Blue.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 855638015
.
This parameter has the configuration ID config_67_4
and is of type INTEGER
.
WallSwipe LED Right gesture action Set the LED indication color of WallSwipe when the gesture action is Right.
- Value 1= Level.
- Value 2= the color value of Red.
- Value 3= the color value of Green.
- Value 4= the color value of Blue.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 855638015
.
This parameter has the configuration ID config_68_4
and is of type INTEGER
.
WallSwipe Night light Set the LED indication color of WallSwipe when it is in Night light state.
Value 1= Level.
Value 2= the color value of Red.
Value 3= the color value of Green.
Value 4= the color value of Blue. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 184483840
.
This parameter has the configuration ID config_69_4
and is of type INTEGER
.
Set the sensitivity of WallSwipe This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_71_1
and is of type INTEGER
.
Set notification sent to associated nodes (group 1) To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmer’s load is changed. The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Send Nothing |
1 | Send Hail CC |
2 | Send Basic CC report |
3 | Send Multilevel Switch report |
4 | Send Hail CC when using the manual switch |
The manufacturer defined default value is 0
((Default) Send Nothing).
This parameter has the configuration ID config_80_1
and is of type INTEGER
.
Set notification sent to associated nodes (group 3) set notification sent to associated nodes (group 4)
To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads. The following option values may be configured -:
Value | Description |
---|---|
0 | Send Nothing |
1 | (Default) Send Basic Set CC |
The manufacturer defined default value is 0
(Send Nothing).
This parameter has the configuration ID config_81_1
and is of type INTEGER
.
Set notification sent to associated nodes (group 4) To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads. The following option values may be configured -:
Value | Description |
---|---|
0 | Send Nothing |
1 | (Default) Send Basic Set CC |
The manufacturer defined default value is 1
((Default) Send Basic Set CC).
This parameter has the configuration ID config_82_1
and is of type INTEGER
.
LED status
The following option values may be configured -:
Value | Description |
---|---|
0 | The LED will follow the status |
1 | Follow the status & turn off after 5 sec. |
2 | Night light mode |
The manufacturer defined default value is 0
(The LED will follow the status).
This parameter has the configuration ID config_83_1
and is of type INTEGER
.
Time set for Night light mode
- Value1: Hour of ON.
- Value2: Minute of ON.
- Value3: Hour of OFF.
- Value4: Minute of OFF.
E.g. The default setting is the Night light mode is enabled at 12: 00 and disabled at 8:00 0x12000800. Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 301991936
.
This parameter has the configuration ID config_84_4
and is of type INTEGER
.
Set appointment 1
0 to 99 The brightness level
256 to 316 The minute value of ON time
65536 to 65560 The hour value of ON time
16777215 to 16777222 The day value (Mon to Sun)
Values in the range 0 to 16843197 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_85_4
and is of type INTEGER
.
Set appointment 2
0 to 99 The brightness level
256 to 316 The minute value of ON time
65536 to 65560 The hour value of ON time
16777215 to 16777222 The day value (Mon to Sun)
Values in the range 0 to 16843197 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_86_4
and is of type INTEGER
.
Enables/disables parameter 91 and 92
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Disable |
1 | Enable |
The manufacturer defined default value is 0
((Default) Disable).
This parameter has the configuration ID config_90_1
and is of type INTEGER
.
Threshold change in wattage (in terms of wattage) to induce an automatic report
Values in the range 0 to 60000 may be set.
The manufacturer defined default value is 25
.
This parameter has the configuration ID config_91_2
and is of type INTEGER
.
Threshold change in wattage (in terms of percentage) Threshold change in wattage (in terms of percentage) to induce an automatic report Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_92_1
and is of type INTEGER
.
Reset parameters 101-103 to default values This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 0 -:
Value | Description |
---|---|
0 | Reset the parameter 101-103 |
The manufacturer defined default value is 0
(Reset the parameter 101-103).
This parameter has the configuration ID config_100_1_wo
and is of type INTEGER
.
This is a write only parameter.
To set which reports need to be sent in Report group 1
1 Send Meter Report of voltage (V)
2 Send Meter Report of current (A)
4 Send Meter Report of wattage (W)
8 Send Meter Report of energy (kWh)
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_101_1
and is of type INTEGER
.
To set which reports need to be sent in Report group 2
1 Send Meter Report of voltage (V)
2 Send Meter Report of current (A)
4 Send Meter Report of wattage (W)
8 Send Meter Report of energy (kWh)
Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_1
and is of type INTEGER
.
To set which reports need to be sent in Report group 3
1 Send Meter Report of voltage (V)
2 Send Meter Report of current (A)
4 Send Meter Report of wattage (W)
8 Send Meter Report of energy (kWh)
Values in the range 0 to 15 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_103_1
and is of type INTEGER
.
Reset parameters 111-113 to default values This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured, in addition to values in the range 0 to 0 -:
Value | Description |
---|---|
0 | Reset the parameter 111-113 |
The manufacturer defined default value is 0
(Reset the parameter 111-113).
This parameter has the configuration ID config_110_1_wo
and is of type INTEGER
.
This is a write only parameter.
Set the interval of automatic report for Report group 1
Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 2147483647
.
This parameter has the configuration ID config_111_4
and is of type INTEGER
.
Set the interval of automatic report for Report group 2
Values in the range 1 to 2147483647 may be set.
The manufacturer defined default value is 2147483647
.
This parameter has the configuration ID config_112_4
and is of type INTEGER
.
Set the interval of automatic report for Report group 3
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 2147483647
.
This parameter has the configuration ID config_113_4
and is of type INTEGER
.
Configure the external switch mode for S1
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Unknown mode |
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Momentary push button mode |
4 | Enter automatic identification mode |
The manufacturer defined default value is 0
((Default) Unknown mode).
This parameter has the configuration ID config_120_1_wo
and is of type INTEGER
.
This is a write only parameter.
Configure the external switch mode for S2
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Unknown mode |
1 | 2-state switch mode |
2 | 3 way switch mode |
3 | Momentary push button mode |
4 | Enter automatic identification mode |
The manufacturer defined default value is 0
((Default) Unknown mode).
This parameter has the configuration ID config_121_1
and is of type INTEGER
.
Get the state of touch panel port
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) the touch panel is not connected. |
5 | the touch panel is connected |
The manufacturer defined default value is 0
((Default) the touch panel is not connected.).
This parameter has the configuration ID config_122_1
and is of type INTEGER
.
Set the control destination for external switch S1
The following option values may be configured -:
Value | Description |
---|---|
1 | control the output loads of itself |
2 | control the other nodes |
3 | Control itself and other nodes |
The manufacturer defined default value is 3
(Control itself and other nodes).
This parameter has the configuration ID config_123_1
and is of type INTEGER
.
Set the control destination for external switch S2
The following option values may be configured -:
Value | Description |
---|---|
1 | control the output loads of itself |
2 | control the other nodes |
3 | Control itself and other nodes |
The manufacturer defined default value is 3
(Control itself and other nodes).
This parameter has the configuration ID config_124_1
and is of type INTEGER
.
The value range is 1 to 255 seconds
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_125_1
and is of type INTEGER
.
Get the current working mode
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Unknown working mode |
1 | 2-wire mode |
2 | 3-wire mode |
The manufacturer defined default value is 0
((Default) Unknown working mode).
This parameter has the configuration ID config_128_1
and is of type INTEGER
.
Set the dimming principle
The following option values may be configured -:
Value | Description |
---|---|
0 | Trailing edge mode |
1 | (Default) Leading edge mode |
The manufacturer defined default value is 1
((Default) Leading edge mode).
This parameter has the configuration ID config_129_1
and is of type INTEGER
.
To get what type of load the Dimmer is connected to.
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Unknown load |
1 | Resistive load |
2 | Capacitive load |
3 | Inductive load |
The manufacturer defined default value is 0
((Default) Unknown load).
This parameter has the configuration ID config_130_1
and is of type INTEGER
.
Set the min brightness level that the load can reach to
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_131_1
and is of type INTEGER
.
Set the max brightness level that the load can reach to
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_132_1
and is of type INTEGER
.
Working way for S1/S2 Set the working way for S1/S2 when the Switch mode is 2 state switch mode.
- Bit 0 =0, S1 is a toggle switch.
- Bit 0 =1, S1 is an On/Off switch, the out load state and S1 switch state would be in sync when using S1 to control the output load.
- Bit 1 =0, S2 is a toggle switch.
- Bit 1 =1, S2 is an On/Off switch, the out load state and S2 switch state would be in sync when using S2 to control the output load.
- Bit 2- Bit 7, reserved.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_247_1
and is of type INTEGER
.
Function of S1/S2 Set the function of S1/S2.
- Bit 0 = 0, the function of sending NIF is disabled.
- Bit 0 = 1, the function of sending NIF is enabled.
- Bit 1 = 0, the function of entering RF power level test mode is disabled.
- Bit 1 = 1, the function of entering RF power level test mode is enabled.
- Bit 2 = 0, the function of factory reset is disabled.
- Bit 2 = 1, the function of factory reset is enabled.
- Bit 3- Bit 6 = reserved.
- Bit 7 = 0, the setting for Bit 0 -Bit 2 are ineffective.
- Bit 7 = 1, the setting for Bit 0 -Bit 2 are effectiveThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 131
.
This parameter has the configuration ID config_248_1
and is of type INTEGER
.
Set the recognition way of load
The following option values may be configured -:
Value | Description |
---|---|
0 | Never recognize the load when power on |
1 | Only recognize once when first power on |
2 | (Default) Recognize the load once power on |
The manufacturer defined default value is 2
((Default) Recognize the load once power on).
This parameter has the configuration ID config_249_1
and is of type INTEGER
.
Lock/unlock configuration parameters
The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) Unlock |
1 | Lock |
The manufacturer defined default value is 0
((Default) Unlock).
This parameter has the configuration ID config_252_1
and is of type INTEGER
.
Reset the Nano Dimmer This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | (Default) factory default |
1431655765 | factory default and remove |
The manufacturer defined default value is 0
((Default) factory default).
This parameter has the configuration ID config_255_4
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZW111 supports 4 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline Z-Wave Plus Lifeline. When the load state of Nano Dimmer (on/off/dim the load ) is changed, the Hail CC, Switch Multilevel Report and Basic Report (configured by parameter 80) can be sent to the associated nodes in this group.
Association group 1 supports 5 nodes.
Forward the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set, Switch all to the associated nodes in Group 2 when the Nano Dimmer receives the Basic Set, Switch Binary Set, Switch Multilevel Start Level Change, Switch Multilevel Stop Level Change, Switch Multilevel Set, Switch all commands from main controller.
Association group 2 supports 5 nodes.
Send Basic Set (configured by parameter 0x51 ) to the associated nodes in Group 3 when the external switch S1 is operated
Association group 3 supports 5 nodes.
Send Basic Set (configured by parameter 0x52) to the associated nodes in Group 4 when the external switch S2 is operated
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_HAIL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.