layout title
documentation
powerSwitch - ZWave

{% include base.html %}

powerSwitch Power Switch EU

This describes the Z-Wave device powerSwitch, manufactured by BeNext with the thing type UID of benext_powerswitch_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

powerSwitch product image

The powerSwitch supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Basic operations

  • The Power Switch can be remotely controlled.
  • The Power Switch can be controlled by the push button on the front of the device.
  • The Power Switch’s indicator light can indicate the status of the switch (ON or OFF).

How it operates

Control and monitor your lightning or any other appliance. Easy plug and play. 

Inclusion Information

Press and hold the push button until the indicator light is blinking than release the button to start the inclusion or exclusion process.

Exclusion Information

Press and hold the push button until the indicator light is blinking than release the button to start the inclusion or exclusion process.

Channels

The following table summarises the channels available for the powerSwitch -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the powerSwitch. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Set to Default Set all configuration values to default values (factory settings)
4 Start up with last known socket status state in what the switch is when power is supplied
9 Relay delay time Relay delay time
10 Led indicator Show the led compared to the relay state
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Set to Default

Set all configuration values to default values (factory settings) All values (0x00 – 0xFF) except for 0x55 can be used to default all the configuration params . Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 4: Start up with last known socket status

state in what the switch is when power is supplied If 0x01–0xFF: When power applied socket is the state before power was disconnected Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 9: Relay delay time

Relay delay time When the relay is switched it can't be switched again until the configured time has passed

Value * 10 milliseconds Values in the range 0 to 255 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Led indicator

Show the led compared to the relay state If value is 0: the indicator led is never switched on If value is 1: the indicator led is switched on when relay is switched on If value is 2: the indicator led is switched on when relay is switched off Values in the range 0 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The powerSwitch supports 1 association group.

Group 1: Group 1

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1