This describes the Z-Wave device RF9542, manufactured by Cooper Wiring Devices with the thing type UID of cooper_rf9542_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The RF9542 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Aspire RF smart dimmer system accessory, compatible with Aspire RF master dimmer (RF9540-N, RF9534, RF9536, RF9536-N, RF9537-N) for wireless 3-way control, eliminating the need for traditional 3-way wiring or dedicated traveller wires.
Put the controller into inclusion mode, press the Install button once
Put the controller into exclusion mode, press the Install button once
The following table summarises the channels available for the RF9542 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Dimmer Ramp Time | config_decimal | config_decimal | Number | |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Local Device Protection | protection_local | protection_local | Number | |
Indicator Light Control | indicator_level | indicator_level | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Sets the local protection mode.
The protection_local
channel is of type protection_local
and supports the Number
item.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Unprotected |
1 | Protection by sequence |
2 | No operation possible |
Sets the indicator brightness.
The indicator_level
channel is of type indicator_level
and supports the Dimmer
item.
The following table provides a summary of the 7 configuration parameters available in the RF9542. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Delayed OFF time | delay time in seconds |
2 | Panic ON time | time in seconds for panic mode |
3 | Panic OFF time | off time in seconds for panic mode |
4 | Basic Set Value | send this value to associated devices |
5 | Power Up State | Power Up State of the switch |
6 | Panic mode enable | Enables this switch to participate in panic mode |
7 | Dimmer Ramp Time | time in seconds to ramp to desired level |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
delay time in seconds The amount of time in seconds the switch will delay when trigger the delayed off feature Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
time in seconds for panic mode The amount of time in seconds the switch will turn on for when panic mode is triggered Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
off time in seconds for panic mode The amount of time in seconds the switch will turn off for when panic mode is triggered Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
send this value to associated devices Setting this to anything other than 0 will cause the value to be transmitted to devices in the association group when the switch is triggered. A setting other than 0 will likely result in undesired operation Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Power Up State of the switch
The following option values may be configured -:
Value | Description |
---|---|
1 | Off |
2 | On |
3 | Last State |
The manufacturer defined default value is 1
(OFF).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Enables this switch to participate in panic mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Off |
2 | On |
The manufacturer defined default value is 1
(OFF).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
time in seconds to ramp to desired level The amount of time in seconds the switch will take to reach the desired dim level Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The RF9542 supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |