RFTR9605-T - ZWave |
{% include base.html %}
This describes the Z-Wave device RFTR9605-T, manufactured by Cooper Wiring Devices with the thing type UID of cooper_rftr9605_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The RFTR9605-T supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Eaton’s Z-Wave Plus Wireless Receptacle replaces regular receptacles to provide local and remote wireless ON/OFF control of a single outlet. Each receptacle can be manually and remotely controlled by commands sent from your compatible Z-Wave certified controller.
Features & Benefits:
- Rated for up to ½ HP motor loads
- Provides Z-Wave control of one outlet leaving the other one for normal use
- Safety shutter system prevents insertion of foreign objects into receptacle
- Can be associated with up to 5 other devices
- Blue LED at center illuminates to indicate ON/OFF status
- Patented indicator system alerts if receptacle is not set up in the network
- Single pole and 3-Way control: Use with standard 3-Way switch or Z-Wave Plus Accessory RF9617
- Neutral is required for installation
- Supports Z-Wave Plus technology including S2 Security certification for advanced encryption & cybersecurity
- Voice and app based control when used with compatible Z-Wave controller
To include this device in a Z-Wave network:
- Select the command on your Z Wave controller for inclusion (Install, Add Device, Add Node, Include Device, etc.).
- Press the device ON/OFF button one time to include it in the network.
- Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR code to install the device as a secured device. You may find this QR code on the device or included in device packaging.
- After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wave network
To exclude this device from a Z-Wave network:
- Select the setting on your Z-Wave controller for exclusion (Uninstall, Remove Device, Remove Node, Exclude Device, etc.).
- Once your controller is in exclusion mode, press the device ON/OFF button one time to exclude it from the network. The LED will start blinking.
The following table summarises the channels available for the RFTR9605-T -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 7 configuration parameters available in the RFTR9605-T. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Delayed OFF Time | Delayed OFF Time |
2 | Panic ON Time | Panic ON Time |
3 | Panic OFF Time | Panic OFF Time |
5 | Power Up State | Power Up State |
6 | Panic Mode Enable | Panic Mode Enable |
13 | BLUE LED Brightness level while ON | BLUE LED Brightness level while the receptacle is ON |
14 | BLUE LED Brightness level while OFF | BLUE LED Brightness level while the receptacle is OFF |
Delayed OFF Time
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Panic ON Time
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Panic OFF Time
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Power Up State
Values in the range 1 to 3 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Panic Mode Enable
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
BLUE LED Brightness level while the receptacle is ON
Values in the range 0 to 4 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
BLUE LED Brightness level while the receptacle is OFF
Values in the range 0 to 4 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
This is a read only parameter.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The RFTR9605-T supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
ON/OFF
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |