RFTR9605-T Wireless Duplex Receptacle

This describes the Z-Wave device RFTR9605-T, manufactured by Cooper Wiring Devices with the thing type UID of cooper_rftr9605_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

RFTR9605-T product image

The RFTR9605-T supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Eaton’s Z-Wave Plus Wireless Receptacle replaces regular receptacles to provide local and remote wireless ON/OFF control of a single outlet. Each receptacle can be manually and remotely controlled by commands sent from your compatible Z-Wave certified controller. 

Features & Benefits:

  • Rated for up to ½ HP motor loads
  • Provides Z-Wave control of one outlet leaving the other one for normal use
  • Safety shutter system prevents insertion of foreign objects into receptacle
  • Can be associated with up to 5 other devices
  • Blue LED at center illuminates to indicate ON/OFF status
  • Patented indicator system alerts if receptacle is not set up in the network
  • Single pole and 3-Way control: Use with standard 3-Way switch or Z-Wave Plus Accessory RF9617
  • Neutral is required for installation
  • Supports Z-Wave Plus technology including S2 Security certification for advanced encryption & cybersecurity
  • Voice and app based control when used with compatible Z-Wave controller

Inclusion Information

To include this device in a Z-Wave network:

  1. Select the command on your Z Wave controller for inclusion (Install, Add Device, Add Node, Include Device, etc.).
  2. Press the device ON/OFF button one time to include it in the network.
  3. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR code to install the device as a secured device. You may find this QR code on the device or included in device packaging.
  4. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wave network

Exclusion Information

To exclude this device from a Z-Wave network:

  1. Select the setting on your Z-Wave controller for exclusion (Uninstall, Remove Device, Remove Node, Exclude Device, etc.).
  2. Once your controller is in exclusion mode, press the device ON/OFF button one time to exclude it from the network. The LED will start blinking.

Channels

The following table summarises the channels available for the RFTR9605-T -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number
Alarm alarm_general alarm_general Alarm Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the RFTR9605-T. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Delayed OFF Time Delayed OFF Time
2 Panic ON Time Panic ON Time
3 Panic OFF Time Panic OFF Time
5 Power Up State Power Up State
6 Panic Mode Enable Panic Mode Enable
13 BLUE LED Brightness level while ON BLUE LED Brightness level while the receptacle is ON
14 BLUE LED Brightness level while OFF BLUE LED Brightness level while the receptacle is OFF

Parameter 1: Delayed OFF Time

Delayed OFF Time

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Panic ON Time

Panic ON Time

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Panic OFF Time

Panic OFF Time

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 5: Power Up State

Power Up State

Values in the range 1 to 3 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Panic Mode Enable

Panic Mode Enable

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 13: BLUE LED Brightness level while ON

BLUE LED Brightness level while the receptacle is ON

Values in the range 0 to 4 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: BLUE LED Brightness level while OFF

BLUE LED Brightness level while the receptacle is OFF

Values in the range 0 to 4 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_14_1 and is of type INTEGER. This is a read only parameter.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The RFTR9605-T supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Group 2

ON/OFF

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1