014G0160 Room Thermostat

This describes the Z-Wave device 014G0160, manufactured by Danfoss with the thing type UID of danfoss_014g0160_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

014G0160 product image

The 014G0160 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The 014G0160 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The Danfoss Link™ RS (Room Sensor) has a built-in temperature sensor, which measures the ambient temperature. It allows you to control the heating, based on room temperature in the room where installed. With the Danfoss Link™ RS you can also adjust the temperature.

Inclusion Information

Push one time LED Button

Exclusion Information

Push one time LED Button

Wakeup Information

The 014G0160 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Any button (LED, Temp+ or Temp-)

General Usage Information

Channels

The following table summarises the channels available for the 014G0160 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Scene Number scene_number scene_number Number
Battery Level battery-level system.battery_level Battery Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 11 configuration parameters available in the 014G0160. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Temperature Report threshold Temperature Report threshold
2 Set-point display resolution range from 0.1 to 10°C 1=0.1°C 100=10°C
3 Min Set-point and override limit from min 0°C to max setpoint override limit 0=0°C 40=40°C
4 Max Set-point and override limit from min setpoint override limit to max 40°C 0=0°C 40=40°C
5 LED Flash period 0 to 65535 seconds
6 Set-point control function 0=Disabled 1=Enabled
7 Temporarily override scheduler 0=Disabled 1=Enabled
8 Set-point type in Thermostat_Setpoint_Reports 1=Heating 2=Cooling 10=Auto Changeover
9 LED on time 1=100ms 5=500ms
10 Number of LED flashes (duration) 0 to 255
11 LED color 1=Green 2=Red
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 1: Temperature Report threshold

Temperature Report threshold Range is from 0.1 to 10°C 1=0.1°C 100=10°C, default value 5 = 0.5 °C Values in the range 1 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: Set-point display resolution

range from 0.1 to 10°C 1=0.1°C 100=10°C

Values in the range 1 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Min Set-point and override limit

from min 0°C to max setpoint override limit 0=0°C 40=40°C

Values in the range 0 to 40 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Max Set-point and override limit

from min setpoint override limit to max 40°C 0=0°C 40=40°C

Values in the range 0 to 40 may be set.

The manufacturer defined default value is 28.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: LED Flash period

0 to 65535 seconds

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_5_4 and is of type INTEGER.

Parameter 6: Set-point control function

0=Disabled 1=Enabled

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (enabled).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Temporarily override scheduler

0=Disabled 1=Enabled

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (enabled).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Set-point type in Thermostat_Setpoint_Reports

1=Heating 2=Cooling 10=Auto Changeover

The following option values may be configured -:

Value Description
1 Heating
2 Cooling
10 Auto-Changeover

The manufacturer defined default value is 1 (Heating).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: LED on time

1=100ms 5=500ms

Values in the range 1 to 5 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: Number of LED flashes (duration)

0 to 255

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: LED color

1=Green 2=Red

The following option values may be configured -:

Value Description
1 Green
2 Red

The manufacturer defined default value is 1 (Green).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_SCHEDULE_V1
COMMAND_CLASS_CENTRAL_SCENE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CMD_V1