layout title
documentation
MT02650 - ZWave

{% include base.html %}

MT02650 Devolo Thermostat (09356)

This describes the Z-Wave device MT02650, manufactured by Danfoss with the thing type UID of danfoss_mt02650_00_000.

The device is in the category of Radiator Control, defining Controls on radiators used to heat up rooms.

MT02650 product image

The MT02650 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The MT02650 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Radiator Thermostat

Inclusion Information

Short push middle button

Exclusion Information

Short push middle button

Wakeup Information

The MT02650 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Short push middle button

General Usage Information

Channels

The following table summarises the channels available for the MT02650 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Local protection protection_local protection_local Number
Battery Level battery-level system.battery_level Battery Number
Clock Time offset time_offset time_offset Time Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Local protection

Sets the local protection mode.

The protection_local channel is of type protection_local and supports the Number item. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Unprotected
1 Protection by sequence
2 No operation possible

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MT02650 supports 2 association groups.

Group 1: Target for Wakeup and Override Notifications

A group of devices that receive temperature reports and an alarm in the event of a sensor shutdown. This group can have up to 10 devices with a controller in mind, which is recommended to be included in this group.

Association group 1 supports 10 nodes.

Group 2: Temprature sensor

A group of connections for connecting a room temperature sensor, in which it will be necessary to add a Z-Wave temperature sensor, the temperature of which the thermostat will use to control the heating device. Only one temperature sensor can be added to this group.

Association group 2 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CMD_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.