This describes the Z-Wave device RXZ-2C, manufactured by Danfoss with the thing type UID of danfoss_rxz2c_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The RXZ-2C supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
230VAC powered static controller with binary switch capability containing 2 power relays
After the device is Factory Reset it automatically enters Inclusion Mode.
- Press PROG to place in Program mode (Red LED on stead)
- Press and hold CH1 button for at least 15 seconds (PROG LED rapidly flashed red and green)
- Press and hold down the PROG button for at least 15 seconds
Channel LEDs will show red and PROG LED will slowly flash green
Factory Reset the device th exclude it.
- Press PROG to place in Program mode (Red LED on stead)
- Press and hold CH1 button for at least 15 seconds (PROG LED rapidly flashed red and green)
- Press and hold down the PROG button for at least 15 seconds
Channel LEDs will show red and PROG LED will slowly flash green
The following table summarises the channels available for the RXZ-2C -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Setpoint (heating) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Setpoint (heating) 2 | thermostat_setpoint2 | thermostat_setpoint | Heating | Number:Temperature |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Sets the thermostat setpoint.
The thermostat_setpoint2
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The RXZ-2C supports 1 association group.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2 | |
COMMAND_CLASS_MULTI_CMD_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.