This describes the Z-Wave device PAN11, manufactured by Devolo with the thing type UID of devolo_pan11_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The PAN11 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This plug-in ON/OFF switch PAN11 is a security enabled wireless switch, based on Z-Wave Plus technology.
Remote On/Off control of the connected load is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAN11 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device.
Pressing On/Off button three times within 2 seconds will enter inclusion mode.
Pressing On/Off button three times within 2 seconds will enter exclusion mode.
The following table summarises the channels available for the PAN11 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 9 configuration parameters available in the PAN11. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Wall Meter Report Period | Wall Meter Report Period |
2 | KWH Meter Report Period | KWH Meter Report Period |
3 | Threshold of current for Load caution | Threshold of current for Load caution |
4 | Threshold of KWH for Load caution | Threshold of KWH for Load caution |
5 | Restore switch state mode | Restore switch state mode |
6 | Mode of Switch Off function | Mode of Switch Off function |
7 | LED indication mode | LED indication mode |
8 | Auto off timer | Auto off timer |
9 | RF off command mode | RF off command mode |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Wall Meter Report Period Unit is 5 seconds
Default value is 720 * 5 s = 3600 s = 1 hour Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
KWH Meter Report Period Unit is 10 minutes
Default is 6 * 10 min = 1 hour Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Threshold of current for Load caution Unit is 0.01 Ampere
Default is 1300 * .01 A = 13 A Values in the range 10 to 1300 may be set.
The manufacturer defined default value is 1300
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
Threshold of KWH for Load caution
Values in the range 1 to 10000 may be set.
The manufacturer defined default value is 10000
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Restore switch state mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | Last switch state (default) |
2 | On |
The manufacturer defined default value is 1
(Last switch state (default)).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Mode of Switch Off function
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable (default) |
The manufacturer defined default value is 1
(Enable (default)).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
LED indication mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Show switch state |
2 | Show night mode |
3 | Flash mode |
The manufacturer defined default value is 1
(Show switch state).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Auto off timer
The following option values may be configured, in addition to values in the range 0 to 32767 -:
Value | Description |
---|---|
0 | Disable auto off function |
The manufacturer defined default value is 0
(Disable auto off function).
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
RF off command mode This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch off (default) |
1 | Ignore |
2 | Switch toggle |
3 | Switch on |
The manufacturer defined default value is 0
(Switch off (default)).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PAN11 supports 1 association group.
Switch will report its latest status to Z-Wave Controller.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |