VOC-SENSOR Air Quality Sensor

This describes the Z-Wave device VOC-SENSOR, manufactured by Eurotronics with the thing type UID of eurotronic_vocsensor_00_000.

The device is in the category of Sensor, defining Device used to measure something.

VOC-SENSOR product image

The VOC-SENSOR supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave sensor in an ultra slim design housing provides comprehensive information on indoor air quality.

Based on these information it is possible to always ensure a healthy living climate.

  • Ultra-flat design housing
  • Use of high-precision, Swiss sensor technology
  • Multicolor LED for signalling ventilation recommendations
  • Returns the following values:
    • VOC value (volatile organic compounds) in ppm
    • CO2 value (as CO2 equivalent) in ppm
    • Temperature (°C) and humidity (%)
    • Dew point (°C)
  • Supports Z-Wave Plus S2 security (encryption)
  • Z-Wave repeater function
  • Operation with plug-in power supply unit

Inclusion Information

Press the back button three times within 1 second.

While the inclusion is active, the LED is blinking green. If the inclusion was successful the green LED will light up for 5 seconds. Otherwise the red led will light up for 5 seconds to indicate failure.

Exclusion Information

Press the back button three times within 1 second.

While the exclusion is active, the LED is blinking green. If the exclusion was successful the green LED will light up for 5 seconds. Otherwise the red led will light up for 5 seconds to indicate failure.

General Usage Information

On factory default the device does not belong to any Z-Wave network Air Quality Sensor Z-Wave Plus needs to be added to an existing wireless network to communicate with the devices of this network.

This process is called Inclusion.

Air Quality Sensor Z-Wave Plus can also be removed from a network.

This process is called Exclusion.

Both processes are initiated by the primary controller of the Z-Wave network.

This controller is turned into exclusion respective inclusion mode.

Please consult the manual of your Z-Wave Controller how to activate Inclusion or Exclusion mode.

If Air Quality Sensor Z-Wave Plus has been added to a network, it has to be removed prior to be added to another wireless network.

Channels

The following table summarises the channels available for the VOC-SENSOR -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (VOLATILE_ORGANIC_COMPOUND) sensor_voc sensor_voc
Sensor (CO2) sensor_co2 sensor_co2 CarbonDioxide Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Sensor (dew point) sensor_dewpoint sensor_dewpoint Temperature Number
Alarm (HOME_HEALTH) alarm_general alarm_general Alarm Switch

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Sensor (VOLATILE_ORGANIC_COMPOUND)

Air Quality Sensor Z-Wave Plus measures the VOC concentration and automatically reports sensor readings to associated devices.

Per default the reporting threshold is ±500ppb.

This parameter can be altered via configuration command class.
Sensor type: „Volatile Organic Compound level“
Scale: Parts/million (ppm)
Precision: 3

Channel type information on this channel is not found.

Sensor (CO2)

Indicates the CO2 level.

The sensor_co2 channel is of type sensor_co2 and supports the Number item and is in the CarbonDioxide category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (dew point)

Indicates the dewpoint.

The sensor_dewpoint channel is of type sensor_dewpoint and supports the Number item and is in the Temperature category. This is a read only channel so will only be updated following state changes from the device.

Alarm (HOME_HEALTH)

Home Health
Air pollution level has changed
Pollution level
0x01: Clean
0x02: Slightly polluted
0x03: Moderately polluted
0x04: Highly polluted

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the VOC-SENSOR. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Temperature on-change reporting Temperature on-change reporting
2 Humidity on-change reporting Humidity on-change reporting
3 Unit Temperature Unit for Temperature (Celsius or Fahrenheit)
4 Resolution Temperature Resolution for Temperature
5 Resolution Humidity Resolution Humidity
6 VOC on-change reporting VOC on-change reporting
7 CO2eq on-change reporting CO2eq on-change reporting
8 Air quality indication via LED Air quality indication via LED

Parameter 1: Temperature on-change reporting

Temperature on-change reporting 0x00 No on-change reporting (only time-based reports).

0x01 - 0x32 report if temperature changed by delta = 0,1°C - 5,0°C Values in the range 0 to 50 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Humidity on-change reporting

Humidity on-change reporting 0x00 No on-change reporting (only time-based reports)

0x01 - 0x0A report if humidity changed by delta = 1% ...10% Values in the range 0 to 10 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Unit Temperature

Unit for Temperature (Celsius or Fahrenheit) 0x00 Temperature reports in Celsius

0x01 Temperature reports in Fahrenheit The following option values may be configured -:

Value Description
0 Celsius
1 Fahrenheit

The manufacturer defined default value is 0 (Celsius).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Resolution Temperature

Resolution for Temperature 0x00 No resolution (example 22°C)

0x01 1/10 resolution (example 22.3°C)

0x02 1/100 resolution (example 22.35°C) The following option values may be configured -:

Value Description
0 No resolution
1 1/10 resolution
2 1/100 resolution

The manufacturer defined default value is 1 (1/10 resolution).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Resolution Humidity

Resolution Humidity 0x00 No resolution (example 33%)

0x01 1/10 resolution (example 33.4%)

0x02 1/100 resolution (example 33.45%) The following option values may be configured -:

Value Description
0 No resolution
1 1/10 resolution
2 1/100 resolution

The manufacturer defined default value is 0 (No resolution).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: VOC on-change reporting

VOC on-change reporting 0x00 No on-change reporting (only time-based reports)

0x01 - 0x0A report if VOC reading changed by 100ppb - 1000ppb Values in the range 0 to 10 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: CO2eq on-change reporting

CO2eq on-change reporting 0x00 No on-change reporting (only time-based reports)

0x01 - 0x0A report if CO2eq reading changed by 100ppm - 1000ppm Values in the range 0 to 10 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Air quality indication via LED

Air quality indication via LED 0x00 No air quality indication via LEDs

0x01 Indicate measured air quality via LEDs Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The VOC-SENSOR supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Air Quality Sensor Z-Wave Plus can be associated with other devices. Commands:

DEVICE_RESET_LOCALLY_NOTIFICATION,NOTIFICATION_REPORT,SENSOR_MULTILEVEL_REPORT

Association group 1 supports 1 node.

Group 2: Temperature

Air Quality Sensor Z-Wave Plus can be associated with other devices. Command: SENSOR_MULTILEVEL_REPORT

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V10
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Documentation Links