T100 Thermostat

This describes the Z-Wave device T100, manufactured by Evolve with the thing type UID of evolve_t100_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

T100 product image

The T100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This thermostat is compatible with most HVAC systems, including the following:

  • 24VAC systems Note: requires both the 24R and 24C (common) wires
  • Standard gas/oil/electric heating systems
    • 1 stage heating and cooling
    • 2 stage heating and cooling
  • Heat Pump systems:
    • 1 stage heating and cooling
    • 2 stage heating and cooling
    • 2nd or 3rd stage Auxiliary heating (heat strips)
  • Do NOT use for line voltage controls (120/240VAC)

Inclusion Information

  1. In the Thermostat's Main Menu, scroll down to the Z-Wave Install item. Select the item.
  2. When prompted by your Z-Wave controller, Press the YES button in the Z-Wave Install screen.

Exclusion Information

  1. In the Thermostat's Main Menu, scroll down to the Z-Wave Remove item. Select the item.
  2. When prompted by your Z-Wave controller, Press the YES button in the Z-Wave Remove screen.

Channels

The following table summarises the channels available for the T100 -:

Channel Name Channel ID Channel Type Category Item Type
Scene Number scene_number scene_number Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate
Clock Time Offset time_offset time_offset Time Number

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1