layout title
documentation
GE/Jasco 14299 - ZWave

{% include base.html %}

GE/Jasco 14299 GE/Jasco In-Wall 1000W Incandescent Smart Dimmer

This describes the Z-Wave device GE/Jasco 14299, manufactured by Jasco Products with the thing type UID of ge_14299_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

GE/Jasco 14299 product image

The GE/Jasco 14299 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Basic operation

The connected light can be turned ON/OFF and adjust dim levels in two ways:

  1. Manually from the front panel of the In-Wall Dimmer.
  2. Remotely with a Z-Wave Controller .

Manual control

The Front Panel Rocker Dimmer allows the user to turn ON/OFF the connected fixture.

  1. To turn the connected fixture ON: press and release the top of the rocker.
  2. To turn the connected fixture OFF: press and release the bottom of the rocker.

Adjust dim level

  1. To increase brightness: press and hold the top of the rocker.
  2. To decrease brightness: press and hold the bottom of the rocker.

Disable / Enable LED

  1. Press UP three (3) times then quickly press and release DOWN one (1) time.
  2. Repeat to disable/enable LED.

This device supports Association Command Class (3 Groups)

  1. Association Group 1 supports Lifeline, Switch Multilevel Report
  2. Association Group 2 supports Basic Set and is controlled by pressing the On or Off button with the local load
  3. Association Group 3 supports Basic Set and is controlled by double pressing the On or Off button
  4. Each Association Group supports 5 total nodes

Inclusion Information

Adding your device to a Z-Wave network

  1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
  2. Once the controller is ready to add your device, press and release the top or bottom of the wireless smart switch (rocker) to add it in the network.

Please reference the controller's manual for instructions.

Exclusion Information

To remove and reset the device

  1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
  2. Once the controller is ready to remove your device, press and release the top or bottom of the wireless smart dimmer (rocker) to remove it from the network.

To return your switch to factory defaults:

Quickly press ON (Top) button three (3) times then immediately press the OFF (Bottom) button three (3) times. The LED will flash ON/OFF 5 times when completed successfully. Note: This should only be used in the event your network’s primary controller is missing or otherwise inoperable.

Wakeup Information

The GE/Jasco 14299 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the GE/Jasco 14299 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the GE/Jasco 14299. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 LED Light LED Light
4 Invert Switch Invert Switch
7 Dim Steps number of steps or levels
8 Dim Timing timing of steps
9 Dim 2 Steps number of steps or levels
10 Dim 2 Timing timing of steps
11 Dim 3 Steps number of steps or levels
12 Dim 3 Timing timing of steps
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: LED Light

LED Light

The following option values may be configured -:

Value Description
0 LED ON when load is OFF
1 LED ON when load is ON
2 LED always OFF

The manufacturer defined default value is 0 (LED ON when load is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Invert Switch

The following option values may be configured -:

Value Description
0 Default
1 Invert Switch

The manufacturer defined default value is 0 (Default).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 7: Dim Steps

number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Dim Timing

timing of steps

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Dim 2 Steps

number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Dim 2 Timing

timing of steps

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Dim 3 Steps

number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Dim 3 Timing

timing of steps

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GE/Jasco 14299 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: controlled with the local load

controlled with the local load Support Basic Set and is controlled with the local load

Association group 2 supports 5 nodes.

Group 3: controlled by double pressing the On or Off button

controlled by double pressing the On or Off button Supports Basic Set and is controlled by double pressing the On or Off button

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_SWITCH_MULTILEVEL_V2
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links