layout | title |
---|---|
documentation |
GE/Jasco 14299 - ZWave |
{% include base.html %}
This describes the Z-Wave device GE/Jasco 14299, manufactured by Jasco Products with the thing type UID of ge_14299_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The GE/Jasco 14299 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Basic operation
The connected light can be turned ON/OFF and adjust dim levels in two ways:
- Manually from the front panel of the In-Wall Dimmer.
- Remotely with a Z-Wave Controller .
Manual control
The Front Panel Rocker Dimmer allows the user to turn ON/OFF the connected fixture.
- To turn the connected fixture ON: press and release the top of the rocker.
- To turn the connected fixture OFF: press and release the bottom of the rocker.
Adjust dim level
- To increase brightness: press and hold the top of the rocker.
- To decrease brightness: press and hold the bottom of the rocker.
Disable / Enable LED
- Press UP three (3) times then quickly press and release DOWN one (1) time.
- Repeat to disable/enable LED.
This device supports Association Command Class (3 Groups)
- Association Group 1 supports Lifeline, Switch Multilevel Report
- Association Group 2 supports Basic Set and is controlled by pressing the On or Off button with the local load
- Association Group 3 supports Basic Set and is controlled by double pressing the On or Off button
- Each Association Group supports 5 total nodes
Adding your device to a Z-Wave network
- Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
- Once the controller is ready to add your device, press and release the top or bottom of the wireless smart switch (rocker) to add it in the network.
Please reference the controller's manual for instructions.
To remove and reset the device
- Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
- Once the controller is ready to remove your device, press and release the top or bottom of the wireless smart dimmer (rocker) to remove it from the network.
To return your switch to factory defaults:
Quickly press ON (Top) button three (3) times then immediately press the OFF (Bottom) button three (3) times. The LED will flash ON/OFF 5 times when completed successfully. Note: This should only be used in the event your network’s primary controller is missing or otherwise inoperable.
The GE/Jasco 14299 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The following table summarises the channels available for the GE/Jasco 14299 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
The following table provides a summary of the 8 configuration parameters available in the GE/Jasco 14299. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | LED Light | LED Light |
4 | Invert Switch | Invert Switch |
7 | Dim Steps | number of steps or levels |
8 | Dim Timing | timing of steps |
9 | Dim 2 Steps | number of steps or levels |
10 | Dim 2 Timing | timing of steps |
11 | Dim 3 Steps | number of steps or levels |
12 | Dim 3 Timing | timing of steps |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
LED Light
The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON when load is OFF |
1 | LED ON when load is ON |
2 | LED always OFF |
The manufacturer defined default value is 0
(LED ON when load is OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Invert Switch
The following option values may be configured -:
Value | Description |
---|---|
0 | Default |
1 | Invert Switch |
The manufacturer defined default value is 0
(Default).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
timing of steps
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
timing of steps
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
timing of steps
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GE/Jasco 14299 supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
controlled with the local load Support Basic Set and is controlled with the local load
Association group 2 supports 5 nodes.
controlled by double pressing the On or Off button Supports Basic Set and is controlled by double pressing the On or Off button
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |