layout title
documentation
GE/Jasco 14321 - ZWave

{% include base.html %}

GE/Jasco 14321 In-Wall Dimmer

This describes the Z-Wave device GE/Jasco 14321, manufactured by Jasco Products with the thing type UID of ge_14321_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

GE/Jasco 14321 product image

The GE/Jasco 14321 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The Jasco Z-Wave Plus Dimmer Wall Switch (Gen5) enables Z-Wave remote control as well as local control for wired dimmable lighting. The rocker switch provides On/Off and Dim/Brighten control and can be included in multiple automation groups or scenes. A blue LED indicator helps guide you to the switch through the dark.

Features

Works with dimmable incandescent CFL and LED lights

Suitable for single-pole or multi-pole applications

Can be included in multiple groups or scenes

"Z-Wave Plus" certified for wide compatibility

Uses a standard decorative-size wallplate (sold separately)

Inclusion Information

Once the controller is ready to add your device, press and release the top or bottom of the dimmer switch (rocker) to add it in the network.

Exclusion Information

Once the controller is ready to remove your device, press and release the top or bottom of the wireless smart switch (rocker) to remove it from the network.

General Usage Information

Channels

The following table summarises the channels available for the GE/Jasco 14321 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the GE/Jasco 14321. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light Defines the behavior of the blue LED.
3 Night Light Defines the behavior of the blue LED
4 Invert Switch Invert the ON/OFF Switch State
7 Dim Rate Adjustments (From Z-Wave Controller) Number of steps or levels
8 Dim Rate Adjustments (From Z-Wave Controller) Timing of steps
9 Dim Rate Adjustments (When Manually Controlled) Number of steps or levels
10 Dim Rate Adjustments (When Manually Controlled) Timing of steps
11 Dim Rate Adjustments (When Receiving All-On/Off Commands) Number of steps or levels
12 Dim Rate Adjustments (When Receiving All-On/Off Command Timing of steps
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Night Light

Defines the behavior of the blue LED. Default is Night Light mode where LED is on when switch is off. The following option values may be configured -:

Value Description
0 LED on when switch is OFF
1 LED on when switch is ON
2 LED is always OFF

The manufacturer defined default value is 0 (LED on when switch is OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 3: Night Light

Defines the behavior of the blue LED This configuration parameter defines the behavior of the blue LED "night light".

The default behavior is "ON_WHEN_OFF" - the LED is on when the switch is set to off.

The other two options are "ON_WHEN_ON" - the LED is on when the switch is set to on, and

"ALWAYS_OFF" - the LED is always off. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Invert the ON/OFF Switch State

The following option values may be configured -:

Value Description
0 No
1 Yes

The manufacturer defined default value is 0 (No).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 7: Dim Rate Adjustments (From Z-Wave Controller)

Number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Dim Rate Adjustments (From Z-Wave Controller)

Timing of steps

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Dim Rate Adjustments (When Manually Controlled)

Number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Dim Rate Adjustments (When Manually Controlled)

Timing of steps

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Dim Rate Adjustments (When Receiving All-On/Off Commands)

Number of steps or levels

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Dim Rate Adjustments (When Receiving All-On/Off Command

Timing of steps

Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GE/Jasco 14321 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Single Press

Association group 2 supports 5 nodes.

Group 3: Double Press

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.