GE/Jasco 14321 - ZWave |
{% include base.html %}
This describes the Z-Wave device GE/Jasco 14321, manufactured by Jasco Products with the thing type UID of ge_14321_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The GE/Jasco 14321 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Jasco Z-Wave Plus Dimmer Wall Switch (Gen5) enables Z-Wave remote control as well as local control for wired dimmable lighting. The rocker switch provides On/Off and Dim/Brighten control and can be included in multiple automation groups or scenes. A blue LED indicator helps guide you to the switch through the dark.
Features
Works with dimmable incandescent CFL and LED lights
Suitable for single-pole or multi-pole applications
Can be included in multiple groups or scenes
"Z-Wave Plus" certified for wide compatibility
Uses a standard decorative-size wallplate (sold separately)
Once the controller is ready to add your device, press and release the top or bottom of the dimmer switch (rocker) to add it in the network.
Once the controller is ready to remove your device, press and release the top or bottom of the wireless smart switch (rocker) to remove it from the network.
The following table summarises the channels available for the GE/Jasco 14321 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
The following table provides a summary of the 9 configuration parameters available in the GE/Jasco 14321. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Night Light | Defines the behavior of the blue LED. |
3 | Night Light | Defines the behavior of the blue LED |
4 | Invert Switch | Invert the ON/OFF Switch State |
7 | Dim Rate Adjustments (From Z-Wave Controller) | Number of steps or levels |
8 | Dim Rate Adjustments (From Z-Wave Controller) | Timing of steps |
9 | Dim Rate Adjustments (When Manually Controlled) | Number of steps or levels |
10 | Dim Rate Adjustments (When Manually Controlled) | Timing of steps |
11 | Dim Rate Adjustments (When Receiving All-On/Off Commands) | Number of steps or levels |
12 | Dim Rate Adjustments (When Receiving All-On/Off Command | Timing of steps |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Defines the behavior of the blue LED. Default is Night Light mode where LED is on when switch is off. The following option values may be configured -:
Value | Description |
---|---|
0 | LED on when switch is OFF |
1 | LED on when switch is ON |
2 | LED is always OFF |
The manufacturer defined default value is 0
(LED on when switch is OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Defines the behavior of the blue LED This configuration parameter defines the behavior of the blue LED "night light".
The default behavior is "ON_WHEN_OFF" - the LED is on when the switch is set to off.
The other two options are "ON_WHEN_ON" - the LED is on when the switch is set to on, and
"ALWAYS_OFF" - the LED is always off. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Invert the ON/OFF Switch State
The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes |
The manufacturer defined default value is 0
(No).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Timing of steps
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
Number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Timing of steps
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
Number of steps or levels
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Timing of steps
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GE/Jasco 14321 supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.