layout | title |
---|---|
documentation |
GE 28175 (ZW3106) - ZWave |
{% include base.html %}
This describes the Z-Wave device GE 28175 (ZW3106), manufactured by Jasco Products with the thing type UID of ge_zw3106_05_023
.
This version of the device is limited to firmware version 5.23
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The GE 28175 (ZW3106) supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
• Remote Control - Turn ON/OFF and control the brightness level of the connected lighting manually or remotely
• Multi-Purpose - 2 USB ports (3.4A total) on each side of the device
• Dual Outlets - Wirelessly control both outlets independently
• Built-in Z-Wave range extender
• OTA (Over-the-Air) Updateable - Utilizes the Z-Wave Firmware Update Meta Data command class
Maximum load (Total): 120VAC, 300W (2.5A) Tungsten, 300W Incandescent, 100W Dimmable CFL/LED
For Indoor Use Only
Quickly press and release the button on the top of the device to enter inclusion mode.
Quickly press and release the button on the top of the device to enter exclusion mode.
Factory Reset: If plugged in, unplug from the receptacle. Press and hold the top button for at least 3 seconds while you plug the switch into the receptacle
The following table summarises the channels available for the GE 28175 (ZW3106) -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer (Both Outlets) | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Left Dimmer | switch_dimmer1 | switch_dimmer | DimmableLight | Dimmer |
Right Dimmer | switch_dimmer2 | switch_dimmer | DimmableLight | Dimmer |
This dimmer controls both outlets on the device simultaneously.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This dimmer controls the outlet on the left side of the device.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer1
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
This dimmer controls the outlet on the right side of the device.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer2
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 8 configuration parameters available in the GE 28175 (ZW3106). Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | LED Light | Adjust Button LED Light |
7 | command steps | number of steps or levels per dim command |
8 | command timing | timing of the command steps |
9 | manual steps | number of steps or levels per dimmer button press |
10 | manual timing | timing of the manual steps |
11 | All on/off steps | number of steps or levels per all on/off command |
12 | All on/off timing | timing of the all on/off command |
29 | load sensing | turn ON when new bulb is sensed |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Adjust Button LED Light OR to invert LED: Change to LED ON when Device Off Press button 10 times quickly The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON / Device OFF |
1 | LED ON / Device ON (Default) |
2 | Disable LED |
The manufacturer defined default value is 1
(LED ON / Device ON (Default)).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
number of steps or levels per dim command When Receiving a Z-Wave Dim Command - Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences.
Parameter 7 (number of steps or levels)
Parameter 8 (timing of the steps) Values in the range 1 to 99 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
timing of the command steps When Receiving a Z-Wave Dim Command - Dim Rate Adjustments
The number of steps that the dimmer will change and the timing of the steps can be modified. The timing of the steps is in 10 millisecond intervals. The default setting “1” means the level will change every 10 milliseconds when the Dim Command is received, dimming will occur 3 times by default for a total of 30 ms. 255 would be every 2.55 seconds. Combined, the two parameters allow dim rates from 10 milliseconds to 4.2 minutes from maximum-to-minimum or minimum-to-maximum levels. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
number of steps or levels per dimmer button press Manual Control Dimming (pressing the Dimmer’s button) - Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences.
Parameter 9 (number of steps or levels)
Parameter 10 (timing of the steps) Values in the range 1 to 99 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
timing of the manual steps Manual Control Dimming (pressing the Dimmer’s button) - Dim Rate Adjustments
The number of steps that the dimmer will change and the timing of the steps can be modified. The timing of the steps is in 10 millisecond intervals. The default setting “1” means the level will change every 10 milliseconds when the Dimmer button is pressed, by default, dimming will occur 3 times per press for a total of 30 ms. 255 would be every 2.55 seconds. Combined, the two parameters allow dim rates from 10 milliseconds to 4.2 minutes from maximum-to-minimum or minimum-to-maximum levels. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
number of steps or levels per all on/off command When Receiving an All-On or All-Off Command - Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences.
Parameter 9 (number of steps or levels)
Parameter 10 (timing of the steps) Values in the range 1 to 99 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
timing of the all on/off command When Receiving an All-On or All-Off Command - Dim Rate Adjustments
The number of steps that the dimmer will change and the timing of the steps. The timing of the steps is in 10 millisecond intervals. The default setting “1” means the level will change every 10 milliseconds when the Command is received, dimming will occur 3 times by default for a total of 30 ms. 255 would be every 2.55 seconds. Combined, the two parameters allow dim rates from 10 milliseconds to 4.2 minutes from maximum-to-minimum or minimum-to-maximum levels. Values in the range 1 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
turn ON when new bulb is sensed Load sensing is disabled when shipped from the factory. Setting parameter 29 to a value of 1 will enable the Load Sense function.
When replacing a burned-out light bulb, the load sensing feature (if enabled) will automatically turn the light ON when the new bulb is installed even if the Z-wave module was previously turned OFF. The following option values may be configured -:
Value | Description |
---|---|
0 | disable (default) |
1 | enable |
The manufacturer defined default value is 0
(disable (default)).
This parameter has the configuration ID config_29_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The GE 28175 (ZW3106) supports 3 association groups.
Lifeline, Switch Multilevel Report
Association group 1 supports 5 nodes.
Basic Set, controlled with the local load
Association group 2 supports 5 nodes.
Basic Set, controlled by double pressing the On or Off button
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.