GE 28175 (ZW3106) Plug-In Dual Smart Dimmer

This describes the Z-Wave device GE 28175 (ZW3106), manufactured by Jasco Products with the thing type UID of ge_zw3106_05_023. This version of the device is limited to firmware version 5.23

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

GE 28175 (ZW3106) product image

The GE 28175 (ZW3106) supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

• Remote Control - Turn ON/OFF and control the brightness level of the connected lighting manually or remotely

• Multi-Purpose - 2 USB ports (3.4A total) on each side of the device

• Dual Outlets -  Wirelessly control both outlets independently 

• Built-in Z-Wave range extender

• OTA (Over-the-Air) Updateable - Utilizes the Z-Wave Firmware Update Meta Data command class 

Maximum load (Total): 120VAC, 300W (2.5A) Tungsten, 300W Incandescent, 100W Dimmable CFL/LED

For Indoor Use Only

Inclusion Information

Quickly press and release the button on the top of the device to enter inclusion mode.

Exclusion Information

Quickly press and release the button on the top of the device to enter exclusion mode.

General Usage Information

Factory Reset: If plugged in, unplug from the receptacle. Press and hold the top button for at least 3 seconds while you plug the switch into the receptacle

Channels

The following table summarises the channels available for the GE 28175 (ZW3106) -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer (Both Outlets) switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number
Left Dimmer switch_dimmer1 switch_dimmer DimmableLight Dimmer
Right Dimmer switch_dimmer2 switch_dimmer DimmableLight Dimmer

Dimmer (Both Outlets)

This dimmer controls both outlets on the device simultaneously.

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Left Dimmer

This dimmer controls the outlet on the left side of the device.

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Right Dimmer

This dimmer controls the outlet on the right side of the device.

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer2 channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the GE 28175 (ZW3106). Detailed information on each parameter can be found in the sections below.

Param Name Description
3 LED Light Adjust Button LED Light
7 command steps number of steps or levels per dim command
8 command timing timing of the command steps
9 manual steps number of steps or levels per dimmer button press
10 manual timing timing of the manual steps
11 All on/off steps number of steps or levels per all on/off command
12 All on/off timing timing of the all on/off command
29 load sensing turn ON when new bulb is sensed
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: LED Light

Adjust Button LED Light OR to invert LED: Change to LED ON when Device Off Press button 10 times quickly The following option values may be configured -:

Value Description
0 LED ON / Device OFF
1 LED ON / Device ON (Default)
2 Disable LED

The manufacturer defined default value is 1 (LED ON / Device ON (Default)).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 7: command steps

number of steps or levels per dim command When Receiving a Z-Wave Dim Command - Dim Rate Adjustments

Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. 

Parameter 7 (number of steps or levels)

Parameter 8 (timing of the steps) Values in the range 1 to 99 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: command timing

timing of the command steps When Receiving a Z-Wave Dim Command - Dim Rate Adjustments

The number of steps that the dimmer will change and the timing of the steps can be modified. The timing of the steps is in 10 millisecond intervals. The default setting “1” means the level will change every 10 milliseconds when the Dim Command is received, dimming will occur 3 times by default for a total of 30 ms. 255 would be every 2.55 seconds. Combined, the two parameters allow dim rates from 10 milliseconds to 4.2 minutes from maximum-to-minimum or minimum-to-maximum levels. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: manual steps

number of steps or levels per dimmer button press Manual Control Dimming (pressing the Dimmer’s button) - Dim Rate Adjustments

Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. 

Parameter 9 (number of steps or levels)

Parameter 10 (timing of the steps) Values in the range 1 to 99 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: manual timing

timing of the manual steps Manual Control Dimming (pressing the Dimmer’s button) - Dim Rate Adjustments

The number of steps that the dimmer will change and the timing of the steps can be modified. The timing of the steps is in 10 millisecond intervals. The default setting “1” means the level will change every 10 milliseconds when the Dimmer button is pressed, by default, dimming will occur 3 times per press for a total of 30 ms. 255 would be every 2.55 seconds. Combined, the two parameters allow dim rates from 10 milliseconds to 4.2 minutes from maximum-to-minimum or minimum-to-maximum levels. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: All on/off steps

number of steps or levels per all on/off command When Receiving an All-On or All-Off Command - Dim Rate Adjustments

Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. 

Parameter 9 (number of steps or levels)

Parameter 10 (timing of the steps) Values in the range 1 to 99 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: All on/off timing

timing of the all on/off command When Receiving an All-On or All-Off Command - Dim Rate Adjustments

The number of steps that the dimmer will change and the timing of the steps. The timing of the steps is in 10 millisecond intervals.  The default setting “1” means the level will change every 10 milliseconds when the Command is received, dimming will occur 3 times by default for a total of 30 ms. 255 would be every 2.55 seconds. Combined, the two parameters allow dim rates from 10 milliseconds to 4.2 minutes from maximum-to-minimum or minimum-to-maximum levels. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 29: load sensing

turn ON when new bulb is sensed Load sensing is disabled when shipped from the factory. Setting parameter 29 to a value of 1 will enable the Load Sense function.

When replacing a burned-out light bulb, the load sensing feature (if enabled) will automatically turn the light ON when the new bulb is installed even if the Z-wave module was previously turned OFF. The following option values may be configured -:

Value Description
0 disable (default)
1 enable

The manufacturer defined default value is 0 (disable (default)).

This parameter has the configuration ID config_29_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The GE 28175 (ZW3106) supports 3 association groups.

Group 1: Group 1

Lifeline, Switch Multilevel Report

Association group 1 supports 5 nodes.

Group 2: Group 2

Basic Set, controlled with the local load

Association group 2 supports 5 nodes.

Group 3: Group 3

Basic Set, controlled by double pressing the On or Off button

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1