layout | title |
---|---|
documentation |
HS-WS200+ - ZWave |
{% include base.html %}
This describes the Z-Wave device HS-WS200+, manufactured by HomeSeer Technologies with the thing type UID of homeseer_hsws200_05_012
.
This version of the device is limited to firmware versions above 5.12
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The HS-WS200+ supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
HS-WS200+ is a Z-Wave Plus relay (on-off) wall switch for use with most lighting and appliance loads. The switch includes an RBG LED indicator which may be controlled wirelessly to suit color preferences or to reflect the changing status of other devices in your home. HS-WS200+ is also designed to trigger automation events with a multi-tap operation (up to 5 taps).
Tap the paddle of your HomeSeer switch to begin the inclusion process. This will take a few moments to complete.
Put your Z-Wave controller into exclusion mode. Tap the paddle of your HomeSeer switch.
The following table summarises the channels available for the HS-WS200+ -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number | |
Mode of Operation | config_decimal | config_decimal | Number | |
Status LED Color | config_decimal | config_decimal | Number | |
Switch LED Blink Frequency | config_decimal | config_decimal | Number | |
Scene Control | config_decimal | config_decimal | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Sets dimmer mode of operation.
0=Normal mode (load status) 1=Status mode (custom status)
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Possible values: 0-7
0=Off, 1=Red, 2=Green, 3=Blue, 4=Magenta, 5=Yellow, 6=Cyan, 7=White
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Possible values: 0, 1-255
0=No blink, 1=100ms ON then 100ms OFF
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
Sets scene control state.
0=Scene control disabled 1=Scene control enabled
Generic class for configuration parameter.
The config_decimal
channel is of type config_decimal
and supports the Number
item.
The following table provides a summary of the 7 configuration parameters available in the HS-WS200+. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Bottom LED Operation | Sets LED operation (in normal mode) |
4 | Orientation | Sets paddle’s load orientation |
6 | Scene Control | Enable or Disable Scene Control |
13 | Status Mode | Sets switch mode of operation |
14 | Load Status LED Color | Sets the Normal mode LED color |
21 | Status LED Color | Sets the Status mode LED color |
31 | Blink Frequency | Sets the switch LED Blink frequency |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Sets LED operation (in normal mode)
The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON if load is OFF |
1 | LED OFF if load is OFF |
The manufacturer defined default value is 0
(LED ON if load is OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Sets paddle’s load orientation
The following option values may be configured -:
Value | Description |
---|---|
0 | Top of Paddle turns load ON |
1 | Bottom of Paddle turns load ON |
The manufacturer defined default value is 0
(Top of Paddle turns load ON).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Enable or Disable Scene Control This parameter allows the Z-Wave central scene command class to be enabled (default) or disabled. If multi-tap operation is not required, disabling the central scene command class will result in instantaneous load control when the paddle is pressed. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Sets switch mode of operation
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal mode (load status) |
1 | Status mode (custom status) |
The manufacturer defined default value is 0
(Normal mode (load status)).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Sets the Normal mode LED color
The following option values may be configured -:
Value | Description |
---|---|
0 | White |
1 | Red |
2 | Green |
3 | Blue |
4 | Magenta |
5 | Yellow |
6 | Cyan |
The manufacturer defined default value is 0
(White).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
Sets the Status mode LED color
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | Red |
2 | Green |
3 | Blue |
4 | Magenta |
5 | Yellow |
6 | Cyan |
7 | White |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Sets the switch LED Blink frequency
The following option values may be configured -:
Value | Description |
---|---|
0 | No blink |
1 | 100ms ON then 100ms OFF |
The manufacturer defined default value is 0
(No blink).
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The HS-WS200+ supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline association only supports the "manual reset" event.
Association group 1 supports 5 nodes.
Any device added to group 2 will be controlled. This allows other WX200 devices to used as companion switches. LEDS will be kept in sync.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.