This describes the Z-Wave device WD500Z-1, manufactured by Linear Corp with the thing type UID of linear_wd500z_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The WD500Z-1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
500W, 120 VAC Wall Mounted Dimmer
Pushing the top or bottom of the switch, the WD500Z-1 allows the user to include or exclude the module from the Z-Wave network.
Pushing the top or bottom of the switch, the WD500Z-1 allows the user to include or exclude the module from the Z-Wave network.
The default Command Poll Period of 1500ms can cause issues with state updating properly after a remote command is received due to the transition period between states of around 2.5s. This manifests as a switch turned fully off in real life, but showing as 50% on in the OpenHAB UI.
Recommended to update this setting to > 2500ms to provide more consistent results.
The following table summarises the channels available for the WD500Z-1 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 6 configuration parameters available in the WD500Z-1. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Dim Start Level | Start dimming from that start level or current level |
3 | LED Indication | The WD500Z-1 will flicker its LED when it is transmitting to any of its groups. |
4 | Invert Switch | Reverse switch direction |
14 | Enable Shade Control Group 2 | The switch can control shade control devices if this parameter is set to 1 |
15 | Enable Shade Control Group 3 | The switch can control shade control devices if this parameter is set to 1. |
19 | LED Transmission Indication | LED mode while transmitting |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Start dimming from that start level or current level A dimmer receiving this command will start dimming from that start level if this bit is set to 0. If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level. The following option values may be configured -:
Value | Description |
---|---|
0 | Use Start Level |
1 | Ignore Start Level |
The manufacturer defined default value is 1
(Ignore Start Level).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
The WD500Z-1 will flicker its LED when it is transmitting to any of its groups.
The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON - Switch ON |
1 | LED ON - Switch OFF |
The manufacturer defined default value is 0
(LED ON - Switch ON).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Reverse switch direction To change the top of the switch to OFF and the bottom to ON change parameter to 1. The following option values may be configured -:
Value | Description |
---|---|
0 | Top-ON, Bottom-OFF |
1 | Bottom-ON, Top-OFF |
The manufacturer defined default value is 0
(Top-ON, Bottom-OFF ).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
The switch can control shade control devices if this parameter is set to 1
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
The switch can control shade control devices if this parameter is set to 1.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
LED mode while transmitting The WD500Z-1 will flicker its LED when it is transmitting to any of its groups.
Parameter set to 0 = not flicker
Parameter set to 1 = flicker the entire time of transmitting
Parameter set to 2 = flicker for only 1 second. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Flicker |
1 | Flicker while transmitting |
2 | Flicker for 1 second |
The manufacturer defined default value is 2
(Flicker for 1 second).
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The WD500Z-1 supports 3 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |