This describes the Z-Wave device MH-C221, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_c221_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

MH-C221 product image

The MH-C221 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

MCO HOME Micro Shutter for windows roller shutter

The device allows for controlling motors of roller blinds, awnings, venetian blinds, gates and others, which are single phase AC powered. This Roller Shutter allows for precise positioning of a roller blind or  venetian blind lamellas. Precise positioning is available for the motors equipped with mechanic and electronic end switches.

The module may be controlled wirelessly, through the Z-Wave network main controller, or through the switch keys connected to it. It’s also possible to combine few devices into groups of devices, which then can be controlled simultaneously. In addition, this Roller Shutter is equipped with Power Metering.

Inclusion Information

  1. Connect the power supply.
  2. Set the main controller into the learn mode (see main controllers operating manual).
  3. Triple click the B-button or a push button connected to the S1 terminal.
  4. MCO Home Roller Shutter will be detected and included into the Z-Wave network

Exclusion Information

  1. Make sure the module is connected to the power supply.
  2. Set the main controller into the learn mode (see main controllers operating manual).
  3. Triple click the B-button or a push button connected to the S1 terminal.

General Usage Information

Control roller shutters, garage door...

Channels

The following table summarises the channels available for the MH-C221 -:

Channel Name Channel ID Channel Type Category Item Type
switch_binary switch_binary switch_binary Switch Switch
blinds control blinds_control blinds_control Blinds Rollershutter
Electric Meter (Watts) 1 meter_watts meter_watts Energy Number
Electric Meter (Volts) meter_voltage meter_voltage Energy Number
Electric Meter (amp) meter_current meter_current Energy Number
Electric Meter (Kwh) meter_kwh meter_kwh Energy Number
Alarm alarm_general alarm_general Alarm Switch

switch_binary

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

blinds control

Provides start / stop control of blinds.

The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Electric Meter (Watts) 1

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric Meter (Volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric Meter (amp)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric Meter (Kwh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 13 configuration parameters available in the MH-C221. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Watt meter report period Watt meter report period
2 KHW meter report period KHW meter report period:Unit 10min,6*10min=1h
3 Threshold of current load - Caution Unit 0.01A 500*0.01A=5A
4 Watt meter report period Watt meter report period
5 Level Report mode 1: Report destination in 5s interval: 2: report every 10% level charge
7 Demo trip 1:activate demo trip and calibration when first touch of the button
9 Demo trip and calibration 1:activate demo trip and calibration
10 A: Auto Calibratio 1:activate calibration only
11 B: Min level of the shutter close 0-98
12 C: Max Level of shutter open 1-99
13 D: External switch type 0: Button (momentary buttons)
1: toggle (2-state switches)
on position-shutter open
off position -shutter close
2: toggle (2-state switches)
on position-shutter close
off postion - shutter open
14 E: External switch input 0: no external switch
1: wire 1 ex, momentary or toggle key to S1 only
2: wire 1 ex, momentary or toggle key to S2 only
3: wire 2 ex, momentary or toggle keys to S1 and S2, each key can control both directions
4: wire 2
255 FF: Factory Setting 85 restore factory setting

Parameter 1: Watt meter report period

Watt meter report period

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: KHW meter report period

KHW meter report period:Unit 10min,6*10min=1h

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Threshold of current load - Caution

Unit 0.01A 500*0.01A=5A

Values in the range 10 to 500 may be set.

The manufacturer defined default value is 500.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Watt meter report period

Watt meter report period

Values in the range 1 to 10000 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Level Report mode

1: Report destination in 5s interval: 2: report every 10% level charge

Values in the range 1 to 2 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 7: Demo trip

1:activate demo trip and calibration when first touch of the button

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 9: Demo trip and calibration

1:activate demo trip and calibration

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: A: Auto Calibratio

1:activate calibration only

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: B: Min level of the shutter close

0-98

Values in the range 0 to 98 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: C: Max Level of shutter open

1-99

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: D: External switch type

0: Button (momentary buttons)
1: toggle (2-state switches)
on position-shutter open
off position -shutter close
2: toggle (2-state switches)
on position-shutter close
off postion - shutter open

Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: E: External switch input

0: no external switch
1: wire 1 ex, momentary or toggle key to S1 only
2: wire 1 ex, momentary or toggle key to S2 only
3: wire 2 ex, momentary or toggle keys to S1 and S2, each key can control both directions
4: wire 2

Values in the range 1 to 4 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 255: FF: Factory Setting

85 restore factory setting

Values in the range 0 to 85 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_255_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MH-C221 supports 3 association groups.

Group 1: Group 1

Association group 1 supports 1 node.

Group 2: Group 2

Association group 2 supports 1 node.

Group 3: Group 3

Association group 3 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.