layout | title |
---|---|
documentation |
MH-C221 - ZWave |
{% include base.html %}
This describes the Z-Wave device MH-C221, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_c221_00_000
.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The MH-C221 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
MCO HOME Micro Shutter for windows roller shutter
The device allows for controlling motors of roller blinds, awnings, venetian blinds, gates and others, which are single phase AC powered. This Roller Shutter allows for precise positioning of a roller blind or venetian blind lamellas. Precise positioning is available for the motors equipped with mechanic and electronic end switches.
The module may be controlled wirelessly, through the Z-Wave network main controller, or through the switch keys connected to it. It’s also possible to combine few devices into groups of devices, which then can be controlled simultaneously. In addition, this Roller Shutter is equipped with Power Metering.
- Connect the power supply.
- Set the main controller into the learn mode (see main controllers operating manual).
- Triple click the B-button or a push button connected to the S1 terminal.
- MCO Home Roller Shutter will be detected and included into the Z-Wave network
- Make sure the module is connected to the power supply.
- Set the main controller into the learn mode (see main controllers operating manual).
- Triple click the B-button or a push button connected to the S1 terminal.
Control roller shutters, garage door...
The following table summarises the channels available for the MH-C221 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
switch_binary | switch_binary | switch_binary | Switch | Switch |
blinds control | blinds_control | blinds_control | Blinds | Rollershutter |
Electric Meter (Watts) 1 | meter_watts | meter_watts | Energy | Number |
Electric Meter (Volts) | meter_voltage | meter_voltage | Energy | Number |
Electric Meter (amp) | meter_current | meter_current | Energy | Number |
Electric Meter (Kwh) | meter_kwh | meter_kwh | Energy | Number |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Provides start / stop control of blinds.
The blinds_control
channel is of type blinds_control
and supports the Rollershutter
item and is in the Blinds
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 13 configuration parameters available in the MH-C221. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Watt meter report period | Watt meter report period |
2 | KHW meter report period | KHW meter report period:Unit 10min,6*10min=1h |
3 | Threshold of current load - Caution | Unit 0.01A 500*0.01A=5A |
4 | Watt meter report period | Watt meter report period |
5 | Level Report mode | 1: Report destination in 5s interval: 2: report every 10% level charge |
7 | Demo trip | 1:activate demo trip and calibration when first touch of the button |
9 | Demo trip and calibration | 1:activate demo trip and calibration |
10 | A: Auto Calibratio | 1:activate calibration only |
11 | B: Min level of the shutter close | 0-98 |
12 | C: Max Level of shutter open | 1-99 |
13 | D: External switch type | 0: Button (momentary buttons) |
1: toggle (2-state switches) | ||
on position-shutter open | ||
off position -shutter close | ||
2: toggle (2-state switches) | ||
on position-shutter close | ||
off postion - shutter open | ||
14 | E: External switch input | 0: no external switch |
1: wire 1 ex, momentary or toggle key to S1 only | ||
2: wire 1 ex, momentary or toggle key to S2 only | ||
3: wire 2 ex, momentary or toggle keys to S1 and S2, each key can control both directions | ||
4: wire 2 | ||
255 | FF: Factory Setting | 85 restore factory setting |
Watt meter report period
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
KHW meter report period:Unit 10min,6*10min=1h
Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Unit 0.01A 500*0.01A=5A
Values in the range 10 to 500 may be set.
The manufacturer defined default value is 500
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
Watt meter report period
Values in the range 1 to 10000 may be set.
The manufacturer defined default value is 10000
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
1: Report destination in 5s interval: 2: report every 10% level charge
Values in the range 1 to 2 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
1:activate demo trip and calibration when first touch of the button
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
1:activate demo trip and calibration
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
1:activate calibration only
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
0-98
Values in the range 0 to 98 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
1-99
Values in the range 1 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
0: Button (momentary buttons)
1: toggle (2-state switches)
on position-shutter open
off position -shutter close
2: toggle (2-state switches)
on position-shutter close
off postion - shutter open
Values in the range 0 to 2 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
0: no external switch
1: wire 1 ex, momentary or toggle key to S1 only
2: wire 1 ex, momentary or toggle key to S2 only
3: wire 2 ex, momentary or toggle keys to S1 and S2, each key can control both directions
4: wire 2
Values in the range 1 to 4 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
85 restore factory setting
Values in the range 0 to 85 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_255_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The MH-C221 supports 3 association groups.
Association group 1 supports 1 node.
Association group 2 supports 1 node.
Association group 3 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.