Skip to content

Latest commit

 

History

History
190 lines (123 loc) · 7.66 KB

mh9co2wa_0_0.md

File metadata and controls

190 lines (123 loc) · 7.66 KB
layout title
documentation
MH9-CO2-WA - ZWave

{% include base.html %}

MH9-CO2-WA CO2 Monitor Air quality detector

This describes the Z-Wave device MH9-CO2-WA, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_mh9co2wa_00_000.

The device is in the category of Sensor, defining Device used to measure something.

MH9-CO2-WA product image

The MH9-CO2-WA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

MCOHome CO2 Monitor is an air quality detector which compatible with Z-Wave technology.

It is mainly used to monitor CO2 concentration in industrial, agricultural, and residence environment, while monitoring the indoor temperature, humidity and VOC (optional) air quality.

Device can be included into any Z-Wave network, and is compatible with any other Z-Wave certified devices.

Specification

  • Power Supply:85~260VAC
  • CO2 display range: 0-2000ppm
  • Default threshold:1000ppm (adjustable)
  • Temperature range:-9.0~50 ℃
  • Humidity range: 0%~99%RH
  • Installation: Wall-mounted (Vertical)
  • Work environment:-10~+8℃ 0-90%RH (Non-condensation)
  • Dimension:90* 130*28mm
  • Hole Pitch:60mm or 82m
  • Housing: Tempered glass+ PC Alloy

Command Class supported by the device

  • COMMAND_CLASS_BASIC
  • COMMAND_CLASS_SENSOR_MULTILEVEL_V5
  • COMMAND_CLASS_CONFIGURATION
  • COMMAND_CLASS_NOTIFICATION
  • COMMAND_CLASS_ASSOCIATION
  • COMMAND_CLASS_MANUFACTURER_SPECIFIC
  • COMMAND_CLASS_VERSION

Inclusion Information

Activate Inclusion/Exclusion mode in the gateway.

When device is powered on, long press K2 can enter interface for inclusion or exclusion of Z-Wave network.

If device has not been included into any Z-Wave network before, “- - -”will display on the screen.

Then press K2 once, “- - -” flashing and device enters into learning mode to get a node ID. If inclusion is success, a node ID will display on the screen. If not, “- - -” will stop flashing in 20 sec.

Exclusion Information

Activate Inclusion/Exclusion mode in the gateway.

When device is powered on, long press K2 can enter interface for inclusion or exclusion of Z-Wave network.

If a node ID displays, it means the device is already in a Z-Wave network.

To press K2 once can remove it from the network. “- - -” displays and press K1 once can return to normal work.

Channels

The following table summarises the channels available for the MH9-CO2-WA -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (CO2) sensor_co2 sensor_co2 CarbonDioxide Number
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Alarm (CO2) alarm_co2 alarm_co2 CarbonDioxide Switch

Sensor (CO2)

Indicates the CO2 level.

The sensor_co2 channel is of type sensor_co2 and supports the Number item and is in the CarbonDioxide category. This is a read only channel so will only be updated following state changes from the device.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Alarm (CO2)

Indicates if the carbon dioxide alarm is triggered.

The alarm_co2 channel is of type alarm_co2 and supports the Switch item and is in the CarbonDioxide category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the MH9-CO2-WA. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Notification Threshold CO2 Notification Threshold

Parameter 1: Notification Threshold

CO2 Notification Threshold Sets the CO2 notification threshold for association group 1.

When the detected CO2 value is higher than the setting value, the device will send a (CO2 Detected Event) report to the Group 1. And this report will keep sending every 30 sec until the detected value is lower than the setting value. Values in the range 1 to 2000 may be set.

The manufacturer defined default value is 1000.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MH9-CO2-WA supports 2 association groups.

Group 1: Notification

sends report ever 30s when CO2 value above threshold Group 1 is for “Notification” purpose, which can add up to 5 Node ID. Device works in “Push” mode in “Notification Command Class”.

When the detected CO2 value is higher than the setting value, the device will send a (CO2 Detected Event) report to the Group 1. And this report will keep sending every 30 sec until the detected value is lower than the setting value.

Use “Notification Set” can set this unsolicited report; this function is default as “OFF”.

Association group 1 supports 5 nodes.

Group 2: Gateway report

CO2, Temperature and Humidity is reported when changed A gateway is suggested to associate with Group 2, which can support only one Node ID. The
gateway can ask for detected data any time. And the device will report to this associated device
(gateway) when detected data changes:
CO2: report when any change ≥50ppm“Multilevel sensor Report (CO2=0x11)”
Temperature: report when any change≥ 0.5 “Multilevel ℃ sensor Report (Temp=0x01)”
Humidity: report when any change≥ 2%“Multilevel sensor Report (Humidity=0x05)’

Association group 2 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SENSOR_CONFIGURATION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.