TPS411 Touch Panel Switch 1 Button

This describes the Z-Wave device TPS411, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_tps411_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

TPS411 product image

The TPS411 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Touch Panel Switch is a wall panel built-in with Z-Wave Plus module. With its stylish design and stable performance, the panel can be used to control house-hold electrical appliances like lamp, motor, coffee machine, TV set etc. It supports basic command class,multi channel command class and multi channel association command class, also works as a repeater in a Z-Wave network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers

Inclusion Information

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

To include the device you only need to press and hold any key for 8 seconds or 3 clicks in quick succession.

Exclusion Information

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

To exclude the device you only need to press and hold any key for 8 seconds or 3 clicks in quick succession.

General Usage Information

The actuator is operated by the local switching Touch pannels or wirelessly using Z-Wave commands.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

  • Press and hold any key on the panel for 10 seconds for restoring factory settings. 
  • Then the node information and association data will be deleted.

**Note:**If factory settings are restored, all INDICATION LEDs on the panel will turn orange, and all switches will turn off.

Channels

The following table summarises the channels available for the TPS411 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Switch 1 switch_binary1 switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the TPS411. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Saving state before power failure Switch state saved or not when power down
3 ALL ON - ALL OFF Allow/forbid ALL ON/ALL OFF
4 LED Backlit brightness level 0=LED disabled 1-10=Min level-Max level
5 Key Mode 0-4
6 Key On duration 0=infinite 1~65535=unit "sec"
8 Basic CC integration setting Basic CC integration setting
14 Disable local control disable local control
15 Disable remote control Disable remote control
255 Factory setting Factory setting
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 2: Saving state before power failure

Switch state saved or not when power down 0= not saved,switch will be off when powered again

1= saved,switch will keep the same state when powered again Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: ALL ON - ALL OFF

Allow/forbid ALL ON/ALL OFF 0=forbid ALL ON, forbid ALL OFF

1=forbid ALL ON, allow ALL OFF

2=allow ALL ON, forbid ALL OFF

255=allow ALL ON, allow ALL OFF Values in the range 0 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: LED Backlit brightness level

0=LED disabled 1-10=Min level-Max level

Values in the range 0 to 10 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Key Mode

0-4 0=single click to switch on/off status

1=Key default as off state. When it is turned on, then it will be turned off automatically after a time period , which can be set in item 5

2=Key default as on state. When it is turned off, then it will be turned on automatically after a time period , which can be set in item 5

3=hold >3s then key is on, and off once released

4=single click to switch on/off status + hold >3s then key is on, and off once released Values in the range 0 to 4 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Key On duration

0=infinite 1~65535=unit "sec"

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 8: Basic CC integration setting

Basic CC integration setting 0: "Basic Set" received, key 1 responds; "Basic Get" received, key 1 sends "Basic Report"; key 1 will not send unsolicited "Basic Report" (No Endpoint) to LifeLine Association

1: "Basic Set" received, key 1 responds; "Basic Get" received, key 1 sends "Basic Report"; key 1 will send unsolicited "Basic Report" (No Endpoint) to LifeLine Association

2: "Basic Set" received, all keys respond; "Basic Get" received, not reply "Basic Report"; All keys will not send unsolicited "Basic Report" (No Endpoint) to LifeLine Association

3: "Basic Set" received, all keys respond; "Basic Get" received, key 1 sends "Basic Report"; All keys will not send unsolicited "Basic Report" (No Endpoint) to LifeLine Association Values in the range 0 to 3 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 14: Disable local control

disable local control 0: All keys are valid for local control

15: All keys are invalid for local control The following option values may be configured, in addition to values in the range 0 to 15 -:

Value Description
0 All keys are valid for local control
15 All keys are invalid for local control

The manufacturer defined default value is 0 (All keys are valid for local control).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Disable remote control

Disable remote control 0: all keys are valid for remote (gateway) control

15: all keys are invalid for remote (gateway) control The following option values may be configured, in addition to values in the range 0 to 15 -:

Value Description
0 all keys are valid for remote (gateway) control
15 all keys are invalid for remote (gateway) control

The manufacturer defined default value is 0 (all keys are valid for remote (gateway) control).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 255: Factory setting

Factory setting Press 20 times of any button or exclude the device from Z-Wave network, the factory setting will be restored Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_255_1_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TPS411 supports 2 association groups.

Group 1: All Status Reports

Association group 1 supports 1 node.

Group 2: Switch Association Group

Triggered by click of touch button

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC