Skip to content

Latest commit

 

History

History
326 lines (216 loc) · 11.3 KB

506004_0_0.md

File metadata and controls

326 lines (216 loc) · 11.3 KB
layout title
documentation
506004 - ZWave

{% include base.html %}

506004 Transmitter Flush-Mounted 4-Gang Switch

This describes the Z-Wave device 506004, manufactured by Merten with the thing type UID of merten_506004_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

506004 product image

The 506004 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The flush-mounted transmitter is a battery-powered radio transmitter to which you can connect up to four make contacts (e.g. push-buttons)

Line pairs are:

  • red/white-red: Input E1
  • green/white-green: Input E2
  • brown/white-brown: Input E3
  • blue/white-blue: Input E4

Attention: The flush-mounted transmitter can be damaged. Never connect the flush mounted transmitter to 230 V

Inclusion Information

Triple click on operating surface of a connected switch

Exclusion Information

Triple click on operating surface of a connected switch

Wakeup Information

The 506004 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Triple click on operating surface of a connected switch. Wait until the LED goes out.

Channels

The following table summarises the channels available for the 506004 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer 1 switch_dimmer switch_dimmer DimmableLight Dimmer
Binary Sensor 1 sensor_binary sensor_binary Switch
Dimmer 2 switch_dimmer1 switch_dimmer DimmableLight Dimmer
Binary Sensor 2 sensor_binary1 sensor_binary Switch
Dimmer 3 switch_dimmer2 switch_dimmer DimmableLight Dimmer
Binary Sensor 3 sensor_binary2 sensor_binary Switch
Dimmer 4 switch_dimmer3 switch_dimmer DimmableLight Dimmer
Binary Sensor 4 sensor_binary3 sensor_binary Switch

Dimmer 1

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Binary Sensor 1

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Dimmer 2

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Binary Sensor 2

Indicates if a sensor has triggered.

The sensor_binary1 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Dimmer 3

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer2 channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Binary Sensor 3

Indicates if a sensor has triggered.

The sensor_binary2 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Dimmer 4

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer3 channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Binary Sensor 4

Indicates if a sensor has triggered.

The sensor_binary3 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the 506004. Detailed information on each parameter can be found in the sections below.

Param Name Description
0 Group 1 (red)
1 Group 2 (green)
2 Group3 (brown)
3 Group 4 (blue)

Parameter 0: Group 1 (red)

The following option values may be configured, in addition to values in the range 0 to 127 -:

Value Description
0 Switching/dimming/shutters dual-surface
4 Switching single-surface
44 Doorbell function
52 LOWER roller shutter as long as button is pressed
54 Move roller shutter single-surface
55 RAISE roller shutter as long as button is pressed

The manufacturer defined default value is 4 (Switching single-surface).

This parameter has the configuration ID config_0_1 and is of type INTEGER.

Parameter 1: Group 2 (green)

The following option values may be configured, in addition to values in the range 0 to 127 -:

Value Description
0 Switching/dimming/shutters dual-surface
4 Switching single-surface
44 Doorbell function
52 LOWER roller shutter as long as button is pressed
54 Move roller shutter single-surface
55 RAISE roller shutter as long as button is pressed

The manufacturer defined default value is 4 (Switching single-surface).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Group3 (brown)

The following option values may be configured, in addition to values in the range 0 to 127 -:

Value Description
0 Switching/dimming/shutters dual-surface
4 Switching single-surface
44 Doorbell function
52 LOWER roller shutter as long as button is pressed
54 Move roller shutter single-surface
55 RAISE roller shutter as long as button is pressed

The manufacturer defined default value is 4 (Switching single-surface).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Group 4 (blue)

The following option values may be configured, in addition to values in the range 0 to 127 -:

Value Description
0 Switching/dimming/shutters dual-surface
4 Switching single-surface
44 Doorbell function
52 LOWER roller shutter as long as button is pressed
54 Move roller shutter single-surface
55 RAISE roller shutter as long as button is pressed

The manufacturer defined default value is 4 (Switching single-surface).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 506004 supports 4 association groups.

Group 1: Red Cables

Association group 1 supports 12 nodes.

Group 2: Green Cables

Association group 2 supports 12 nodes.

Group 3: Brown Cables

Association group 3 supports 12 nodes.

Group 4: Blue Cables

Association group 4 supports 12 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1
COMMAND_CLASS_MULTI_CHANNEL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1
COMMAND_CLASS_MULTI_CHANNEL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1
COMMAND_CLASS_MULTI_CHANNEL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1

Endpoint 3

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_BASIC_WINDOW_COVERING_V1
COMMAND_CLASS_MULTI_CHANNEL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.