layout | title |
---|---|
documentation |
1402756 - ZWave |
{% include base.html %}
This describes the Z-Wave device 1402756, manufactured by Namron with the thing type UID of namron_1402756_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The 1402756 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This is a switch multilevel device based on Z-wave enhanced 232 slave library of V6.81.03, and it can be easy configuration, operate and can make traditional LED dimmable lighting to be intelligent control.
- Set primary controller/gateway into inclusion mode (Please refer top your primary controllers manual on how to set your controller into inclusion).
- Power on the in-wall dimmer.
- Tripple Press the reset button on the dimmer, it will set the dimmer into inclusion mode.
The purple indicator light will stay solid on for 10 seconds to indicate successful incusion.
There are two exclusion methods:
- Method 1:
- Set the primary controller/gateway int exclusion mode (Please refer top your primary controllers manual on how to set your controller into exclusion).
- Triple press the reset button, the dimmer will be set to exclusion mode, and wait to be excluded, then the dimmer will be excluded form the network.
- Method 2: Factory reset the dimmer will force the it to be excluded form a network. (Please refer to the part "Factory Reset" of the manual
Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable.
Factory Reset
Press and hold down the reset button for over 5 seconds, the dimmer will be reset to factory defaults
The following table summarises the channels available for the 1402756 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 7 configuration parameters available in the 1402756. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | State After Power Restore | State After Power Restore |
2 | Notification when load status change | Notification when load status change |
3 | Default dimming speed | Default dimming speed |
5 | Enable or Disable external switch to pair network | Enable or Disable external switch to pair network |
6 | Setting dimming way | Setting dimming way |
7 | Setting default brightness when turn on | Setting default brightness when turn on the dimmer from off status |
8 | Setting delay time when turn off the load | Setting delay time when turn off the load |
State After Power Restore State After Power Restore: The state the switch should return to once power is restored after power failure
0 - off
1 - on
2 - Returns to level before Power Outage Values in the range 0 to 2 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Notification when load status change Notification when load status change: The Dimmer will send notification to associated device(Group Lifeline) when status of DImmer load is changed:
0 - The function is disabled
1 - Send Switch Multilevel Report Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Default dimming speed Default dimming speed. Valid Value: 0-100
0 - Instantly
1 - Fast
...
100 - Slow Values in the range 0 to 100 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Enable or Disable external switch to pair network Enable or Disable external switch to pair network.
0 - Disable
1 - Enable Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Setting dimming way Setting dimming way.
0 - Linear dimming
1 - Logarithmic dimming Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Setting default brightness when turn on the dimmer from off status Setting default brightness when turn on the dimmer from off status
Setting 0 means that the dimmer will use parameter 1.
Valid value: 0 - 99 Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Setting delay time when turn off the load Setting delay time when turn off the load, unit is second.
Valid value: 0 - 60 Values in the range 0 to 60 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 1402756 supports 4 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. The ASSIC of Lifeline:4C 69 66 65 6C 69 6E 65
- when press and hold down "Reset" button over 5s to reset the dimmer send "Device Reset Locally Notification CC" to associated devices of this group to report factory reset information.
- When load state chages send "Switch Multilevel Report CC" to associated devices of this group.
Association group 1 supports 5 nodes.
Basic Set: 42 61 73 69 63 20 53 65 74
- Short press "Knob" turn on the dimmer Sends Basic Set(0XFF) to associeated devices.
- Short press "Knob" turn off the dimmer Sends Basic Set (0X00) to associated devices.
Association group 2 supports 5 nodes.
Switch Multilevel: 53 77 69 74 63 68 20 4D 75 6C 74 69 6C 65 76 65 6C
- "Turn knob to the left" sends Switch Multilevel Set(to keep associated devices in sync with this device) to associated devices.
- "Turn knob to the right" Sends Switch Multilevel Set(to keep associated devices in sync with this device) to associated devices.
Association group 3 supports 5 nodes.
External Button: 45 78 74 65 72 6E 61 6C 20 42 75 74 74 6F 6E
- External Button hold send Switch Multilevel Start Level Change(Switchover dimmer Up/Down)
- External Button release send Switch Multilevel Stop Level Change.
Association group 4 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V2 | Linked to BASIC |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.