NZW36 On/Off Smart Plug + Signal Repeater (Z-Wave Plus)

This describes the Z-Wave device NZW36, manufactured by NIE Technology with the thing type UID of nietech_nzw36_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

NZW36 product image

The NZW36 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Plug the Smart Outlet in. Sync. Control Lights & Appliances from Anywhere.

Control your lights and appliances with the Inovelli® Z-Wave Plus plug-in on/off smart outlet. In addition to being able to remotely control your devices, this smart plug also acts as a Z-Wave signal booster (repeater), giving you best of both worlds.

Inclusion Information

Alright, let’s include your device!

Including Steps:

  • Go ahead and put your HUB/Gateway in inclusion/pairing mode
  • While your HUB/Gateway is in inclusion mode, press the Middle Button on the front of your NZW36 five (5) times rapidly within 1-2 seconds

Check to make sure your device turns on and off and if so, congratulations, you now have remote control over your lights!

STILL CAN’T GET IT TO PAIR? You may need to exclude the device first. While this is rare, sometimes it happens. Please click see the, “Exclusion / Device Removal” section below. Once that’s completed, please return here.

**If you are having issues pairing your device, please make sure you are within range above. If you are confident you are, please click on the, “Exclusion / Device Removal” tab below to exclude your device first**

Exclusion Information

Please follow the below directions to exclude/remove your smart plug from your HUB/Gateway.

Exclusion/Removal Steps:

  • Put your HUB/Gateway in exclusion/removal mode
  • Press the Middle Button on the front of your NZW36 five (5) times rapidly (within 1-2 seconds)

Your smart plug should now be removed from your HUB/Gateway.

**If you are having issues removing your device, try removing the device directly next to the HUB. This will solve 95% of all problems you may have when removing**

Channels

The following table summarises the channels available for the NZW36 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number
Alarm alarm_general alarm_general Alarm Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the NZW36. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED Indicator
2 Countdown Plug Auto Shut Off
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: LED Indicator

The following option values may be configured -:

Value Description
0 Plug On / LED On
1 Plug On / LED Off
2 LED Disabled

The manufacturer defined default value is 0 (Plug On / LED On).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Countdown

Plug Auto Shut Off Plug auto shutoff

0 - 36000 seconds Values in the range 0 to 36000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The NZW36 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Documentation Links