layout | title |
---|---|
documentation |
NZW96 - ZWave |
{% include base.html %}
This describes the Z-Wave device NZW96, manufactured by NIE Technology with the thing type UID of nietech_nzw96_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The NZW96 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Plug the Smart Outlet in. Sync. Control Your Outdoor Device from Anywhere.
Control your outdoor device with the Inovelli® Z-Wave Plus plug-in smart outlet + Z-Wave Repeater. With an IP65 rating, you can feel safe leaving your lights plugged in even in the harshest of weather (trust us, the Winters are frigid here in Michigan).
Alright, let’s include your device!
Including Steps:
- Go ahead and put your HUB/Gateway in inclusion/pairing mode
- While your HUB/Gateway is in inclusion mode, press the Middle Button on the front of your NZW96 five (5) times rapidly within 1-2 seconds
Check to make sure your device turns on and off and if so, congratulations, you now have remote control over your lights!
STILL CAN’T GET IT TO PAIR? You may need to exclude the device first. While this is rare, sometimes it happens. Please click see the, “Exclusion / Device Removal” section below. Once that’s completed, please return here.
**If you are having issues pairing your device, please make sure you are within range above. If you are confident you are, please click on the, “Exclusion / Device Removal” tab below to exclude your device first**
Please follow the below directions to exclude/remove your smart plug from your HUB/Gateway.
Exclusion/Removal Steps:
- Put your HUB/Gateway in exclusion/removal mode
- Press the Middle Button on the front of your NZW96 five (5) times rapidly (within 1-2 seconds)
Your smart plug should now be removed from your HUB/Gateway.
**If you are having issues removing your device, try removing the device directly next to the HUB. This will solve 95% of all problems you may have when removing**
The following table summarises the channels available for the NZW96 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Alarm (heat) | alarm_heat | alarm_heat | Fire | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates if a heat alarm is triggered.
The alarm_heat
channel is of type alarm_heat
and supports the Switch
item and is in the Fire
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 2 configuration parameters available in the NZW96. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | LED Invert/Off | LED Invert/Off |
2 | Countdown | Plug Auto Shutoff |
LED Invert/Off
The following option values may be configured -:
Value | Description |
---|---|
0 | Plug On / LED On |
1 | Plug On / LED Off |
2 | LED Disabled |
The manufacturer defined default value is 0
(Plug On / LED On).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Plug Auto Shutoff Plug Auto Shutoff
0 - 36000 seconds Values in the range 0 to 36000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The NZW96 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.