layout | title |
---|---|
documentation |
PAN05-1B - ZWave |
{% include base.html %}
This describes the Z-Wave device PAN05-1B, manufactured by Philio Technology Corp with the thing type UID of philio_pan05_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The PAN05-1B supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This in-wall switch module is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. Since PAN05 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device.
Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode
Pressing Include button of PAN05 three times within 2 seconds will enter exclusion mode.
The following table summarises the channels available for the PAN05-1B -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 6 configuration parameters available in the PAN05-1B. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Mode | Mode |
2 | Restore switch state mode | Restore switch state mode |
3 | Manual On/Off mode | Manual On/Off mode |
4 | LED indication mode | LED indication mode |
5 | Auto off timer | Auto off timer |
6 | RF Off command mode | RF Off command mode |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Mode Edge or Pulse mode or Edge-Toggle mode The following option values may be configured -:
Value | Description |
---|---|
1 | Edge mode |
2 | Pulse mode |
3 | Edge-Toggle mode |
The manufacturer defined default value is 1
(Edge mode).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Restore switch state mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Switch Off |
1 | Last Switch State |
2 | Switch On |
The manufacturer defined default value is 1
( Last Switch State ).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Manual On/Off mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable manual On/Off |
1 | Enable manual On/Off |
The manufacturer defined default value is 1
(Enable manual On/Off).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
LED indication mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Show switch state |
2 | Show night mode |
3 | One flash mode |
The manufacturer defined default value is 1
(Show switch state ).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Auto off timer 0:Disable auto off function
1-32767:1 ~ 32767 seconds Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
RF Off command mode Whenever a RF Off command is received, BASIC_SET、BINARY_SWITCH_SET、 SWITCH_ALL_OFF, it could be interpreted as
- Switch Off、
- Switch On、
- Switch Toggle, or
- it would be ignored.
The default value is Switch Off. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch off |
1 | Ignore |
2 | Switch toggle |
3 | Switch on |
The manufacturer defined default value is 0
(Switch off).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PAN05-1B supports 1 association group.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.