Skip to content

Files

Latest commit

 Cannot retrieve latest commit at this time.

History

History
234 lines (149 loc) · 7.23 KB

pan05_0_0.md

File metadata and controls

234 lines (149 loc) · 7.23 KB
layout title
documentation
PAN05-1B - ZWave

{% include base.html %}

PAN05-1B Single relay in-wall switch module

This describes the Z-Wave device PAN05-1B, manufactured by Philio Technology Corp with the thing type UID of philio_pan05_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

PAN05-1B product image

The PAN05-1B supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This in-wall switch module is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network. Mini size design let the module can easily hide itself into the wall box and that will be good for the house decoration. Since PAN05 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device.  

Inclusion Information

Pressing Include button of PAN05 three times within 2 seconds will enter inclusion mode

Exclusion Information

Pressing Include button of PAN05 three times within 2 seconds will enter exclusion mode. 

Channels

The following table summarises the channels available for the PAN05-1B -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm alarm_general alarm_general Alarm Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the PAN05-1B. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Mode Mode
2 Restore switch state mode Restore switch state mode
3 Manual On/Off mode Manual On/Off mode
4 LED indication mode LED indication mode
5 Auto off timer Auto off timer
6 RF Off command mode RF Off command mode
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Mode

Mode Edge or Pulse mode or Edge-Toggle mode The following option values may be configured -:

Value Description
1 Edge mode
2 Pulse mode
3 Edge-Toggle mode

The manufacturer defined default value is 1 (Edge mode).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Restore switch state mode

Restore switch state mode

The following option values may be configured -:

Value Description
0 Switch Off
1 Last Switch State
2 Switch On

The manufacturer defined default value is 1 ( Last Switch State ).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Manual On/Off mode

Manual On/Off mode

The following option values may be configured -:

Value Description
0 Disable manual On/Off
1 Enable manual On/Off

The manufacturer defined default value is 1 (Enable manual On/Off).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: LED indication mode

LED indication mode

The following option values may be configured -:

Value Description
1 Show switch state
2 Show night mode
3 One flash mode

The manufacturer defined default value is 1 (Show switch state ).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Auto off timer

Auto off timer 0:Disable auto off function

1-32767:1 ~ 32767 seconds Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: RF Off command mode

RF Off command mode Whenever a RF Off command is received, BASIC_SET、BINARY_SWITCH_SET、 SWITCH_ALL_OFF, it could be interpreted as

  • Switch Off、
  • Switch On、
  • Switch Toggle, or
  • it would be ignored.

The default value is Switch Off.  The following option values may be configured -:

Value Description
0 Switch off
1 Ignore
2 Switch toggle
3 Switch on

The manufacturer defined default value is 0 (Switch off).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN05-1B supports 1 association group.

Group 1: Group 1

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.