This describes the Z-Wave device PAT05, manufactured by Philio Technology Corp with the thing type UID of philio_pat05_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The PAT05 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The PAT05 multi-sensor is a device that allows you to check the air quality in your home, as well as detect temperature and humidity.
The PAT05 Multi-sensor is easy to use and very convenient for your home. Just set the sensor on the wall of the rooms you would like to control, and you are ready to go.
-
Have Z-WaveTM Controller entered inclusion mode.
-
Pressing tamper key three times within 2 seconds to enter the inclusion mode.
-
After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
-
Have Z-WaveTM Controller entered exclusion mode.
-
Pressing tamper key three times within 2 seconds to enter the exclusion mode.
Node ID has been excluded.
The following table summarises the channels available for the PAT05 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (VOLATILE_ORGANIC_COMPOUND) | sensor_voc | sensor_voc | ||
Sensor (CO2) | sensor_co2 | sensor_co2 | CarbonDioxide | Number |
Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch |
Channel type information on this channel is not found.
Indicates the CO2 level.
The sensor_co2
channel is of type sensor_co2
and supports the Number
item and is in the CarbonDioxide
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel is of type alarm_burglar
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 16 configuration parameters available in the PAT05. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | CO2 Threshold line 1 | eCO2 difference return |
4 | CO2 Threshold line 2 | eCO2 difference return |
5 | eCO2 Threshold line 3 | eCO2 difference return |
6 | eCO2 Threshold line 4 | eCO2 difference return |
7 | eCO2 Threshold line 5 | eCO2 difference return |
8 | TVOC Threshold line 1 | TVOC difference return |
9 | TVOC Threshold line 2 | TVOC difference return |
10 | TVOC Threshold line 3 | TVOC difference return |
11 | TVOC Threshold line 4 | TVOC difference return |
12 | TVOC Threshold line 5 | TVOC difference return |
13 | Customer Function | Customer function switch, using bit control. |
14 | ECO2 Auto Report Time | The interval time for auto report the eCO2. |
15 | TVOC Auto Report Time | The interval time for auto report the TVOC. |
16 | Auto Report Tick Interval | The interval time for auto report each tick. |
17 | CO2 Differential percent Report | The eCO2 Differential to report. |
18 | TVOC Differential percent Report | The TVOC Differential to report |
eCO2 difference return The Unit is 100ppm.
0 means turn off eCO2 detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
eCO2 difference return The Unit is 100ppm.
0 means turn off eCO2 detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
eCO2 difference return The Unit is 100ppm.
0 means turn off eCO2 detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
eCO2 difference return The Unit is 100ppm.
0 means turn off eCO2 detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 16
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
eCO2 difference return The Unit is 100ppm.
0 means turn off eCO2 detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
TVOC difference return The Unit is 100ppb.
0 means turn off TVOC detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
TVOC difference return The Unit is 100ppb.
0 means turn off TVOC detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
TVOC difference return The Unit is 100ppb.
0 means turn off TVOC detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
TVOC difference return The Unit is 100ppb.
0 means turn off TVOC detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 22
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
TVOC difference return The Unit is 100ppb.
0 means turn off TVOC detected function. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 55
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Customer function switch, using bit control.
The following option values may be configured -:
Value | Description |
---|---|
0 | Tamper OFF |
1 | Tamper ON |
The manufacturer defined default value is 1
(Tamper ON).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
The interval time for auto report the eCO2. 0 means turn off auto report eCO2.
The default value is 1.
The tick time can setting by the configuration No.16 Values in the range 0 to 127 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
The interval time for auto report the TVOC. 0 means turn off auto report TVOC.
The default value is 1.
The tick time can setting by the configuration No.16. Values in the range 0 to 127 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
The interval time for auto report each tick. Setting this configuration will effect configuration No.14 and No.15.
The unit is 1 minute.
Caution1: Setting to 0 means turn off all auto report function.
Caution2: The value is unsigned byte, the range is from 0x00 ~ 0xFF.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
The eCO2 Differential to report. 0 means turn off this function.
The unit is percentage.
Enable this function the device will detect every percentage.
And when the CO2 Sensor is over 10 percentage, it will continue report.
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
The TVOC Differential to report 0 means turn off this function.
The unit is percentage.
Enable this function the device will detect every percentage.
And when the TVOC Sensor is over 10 percentage, it will continue report. Values in the range 0 to 100 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PAT05 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V10 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |