This describes the Z-Wave device UMV3-BTZ, manufactured by Poly-control with the thing type UID of polycontrol_umv3btze_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The UMV3-BTZ supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The Universal Model V3 supports: - S0/S2 Z-Wave Security - Can operate 3 outputs. - Outputs can be delayed. - Bluetooth Smart
The UMV3 can be set to factory settings by pushing the switch 10 times. Please use this procedure only when the primary controller is missing or otherwise inoperable.
To add or include the UMV3 into a Z-Wave network 1. Set the controller in inclusion mode 2. Push the switch once. 3. Wait 5 seconds.
To remove or exclude the UMV3 into a Z-Wave network 1. Set the controller in exclusion mode 2. Push the switch once. 3. Wait 5 seconds.
The following table summarises the channels available for the UMV3-BTZ -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Entry Alarm | alarm_entry | alarm_entry | Door | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if the entry alarm is triggered.
The alarm_entry
channel is of type alarm_entry
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Open |
OFF | Closed |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 12 configuration parameters available in the UMV3-BTZ. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Relay 1 Pulse length (ms) | Time the relay is on in milliseconds. |
2 | Relay 1 Delay length (ms) | Time before the relay is activated. |
3 | Relay 2 Pulse length (ms) | Time the relay is on in milliseconds. |
4 | Relay 2 Delay length (ms) | Time before the relay is activated. |
5 | Relay 3 Pulse length (ms) | Time the relay is on in milliseconds. |
6 | Relay 3 Delay length (ms) | Time before the relay is activated. |
7 | Disable battery alarm | Disable battery alarm0 = Battery Alarm enable,1 = Battery Alarm disable |
8 | Battery Sample Interval Seconds | Battery Sample Interval Seconds |
9 | Battery Milli Volt Level Threshold Maximum | Maximum battery alarm level in mV. |
10 | Battery Milli Volt Level Threshold Minimum | Minimum battery alarm level in mV. |
11 | Ble temporary allow – timer - seconds | Allow Bluetooth to be on for a time in seconds |
12 | BLE Always allowed | 0 = Not always allowed. 1= Always allowed. |
Lock Timeout | Sets the time after which the door will auto lock |
Time the relay is on in milliseconds.
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 5000
.
This parameter has the configuration ID config_1_4
and is of type INTEGER
.
Time before the relay is activated.
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_4
and is of type INTEGER
.
Time the relay is on in milliseconds.
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 5000
.
This parameter has the configuration ID config_3_4
and is of type INTEGER
.
Time before the relay is activated.
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_4
and is of type INTEGER
.
Time the relay is on in milliseconds.
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 5000
.
This parameter has the configuration ID config_5_4
and is of type INTEGER
.
Time before the relay is activated.
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_4
and is of type INTEGER
.
Disable battery alarm0 = Battery Alarm enable,1 = Battery Alarm disable
The following option values may be configured -:
Value | Description |
---|---|
0 | Battery Alarm enable |
1 | Battery Alarm disable |
The manufacturer defined default value is 0
(Battery Alarm enable).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Battery Sample Interval Seconds
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_8_4
and is of type INTEGER
.
Maximum battery alarm level in mV.
Values in the range 0 to 12100 may be set.
The manufacturer defined default value is 12100
.
This parameter has the configuration ID config_9_4
and is of type INTEGER
.
Minimum battery alarm level in mV.
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 11600
.
This parameter has the configuration ID config_10_4
and is of type INTEGER
.
Allow Bluetooth to be on for a time in seconds
Values in the range 0 to 2147483647 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_4
and is of type INTEGER
.
0 = Not always allowed. 1= Always allowed.
The following option values may be configured -:
Value | Description |
---|---|
0 | Not always allowed |
1 | Always allowed |
The manufacturer defined default value is 0
(Not always allowed).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The UMV3-BTZ supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |