This describes the Z-Wave device 004001, manufactured by Popp & Co with the thing type UID of popp_004001_00_000
.
The device is in the category of Smoke Detector, defining Smoke detectors.
The 004001 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
This product combines a certified stand-alone smoke detector with an insertable Z-Wave module. The smoke detector is certified by the VdS and DIN EN 14604 and satisfies all legal requirements. The smokebox is made of steel and antistatic plastic.
A button on the device can be used to test the smokebox, the electronics and the battery. In addition the device has an integrated test functionality to make manual tests with Aerosol unnecessary. The battery warning gets send for at least 30 days. During this time the smoke sensor stays fully functional.
The Z-Wave radio module enables the smoke and battery alarms to be transmitted to a central Z-Wave controller. The smoke sensor can also be used as Z-Wave siren; for that the Z-Wave controller sends an on or off command to the siren. The radio module uses either the smoke sensors integrated 9V battery or can be powered by an external 12V power supply.
According to the VdS 3515 (smoke sensors with radio communication) this device will relay all alarms to all other smoke sensors (004001) in the Z-Wave network to create a house-wide alarm. This connection of the smoke sensors is fully automatical and needs no further configuration. The smoke sensors and the controller communicate via an secure protocol to prevent manipulation.
A single click on the button (3) includes the device. If the button is pressed for at least 2 seconds the inclusion will be done without the (Security Command Class ).
A single click on the button will exclude the device.
<td>
<strong>sensor_binary</strong>
</td>
<td>
<strong>switch_binary</strong>
</td>
<td>
yes
</td>
<td>
no
</td>
<td>
yes
</td>
<td>
no
</td>
<td>
yes
</td>
<td>
yes
</td>
Eventtrigger |
Smoke detection |
Low Battery (0 %) |
Siren switched ON manually |
The following table summarises the channels available for the 004001 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 6 configuration parameters available in the 004001. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Siren alarm sequence interval in seconds | This parameter defines the total length of the interval in seconds. |
2 | Siren alarm tone length | Total length of the sound versus silence within this interval. |
3 | Value of On-Command | |
4 | Value of Off-Command | |
5 | Status of automated meshing of smoke alarms | Inform other smoke detectors of same type about smoke alarms |
6 | Status of automated meshing of battery alarms | Inform other smoke detectors of same type about battery alarms |
This parameter defines the total length of the interval in seconds. The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. Values in the range 3 to 129 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Total length of the sound versus silence within this interval. The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. Values in the range 3 to 129 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Inform other smoke detectors of same type about smoke alarms This smoke detector can automatically inform other smoke detectors of same type about smoke alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors. The following option values may be configured -:
Value | Description |
---|---|
0 | inactive |
1 | active |
The manufacturer defined default value is 1
(active).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Inform other smoke detectors of same type about battery alarms This smoke detector can automatically inform other smoke detectors of same type about battery alarms. They will then also turn on the siren. This function is a requirement of wireless networked smoke detectors. The following option values may be configured -:
Value | Description |
---|---|
0 | inactive |
1 | active |
The manufacturer defined default value is 1
(active).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 004001 supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 4 nodes.
Association group 2 supports 4 nodes.
Association group 3 supports 4 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |