layout | title |
---|---|
documentation |
009402 - ZWave |
{% include base.html %}
This describes the Z-Wave device 009402, manufactured by Popp & Co with the thing type UID of popp_009402_00_000
.
This version of the device is limited to firmware versions below 1.1
The device is in the category of Smoke Detector, defining Smoke detectors.
The 009402 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
This product combines a certified '10 year' stand-alone smoke detector with a plug-in Z-Wave module to form a wirelessly reporting automatically meshing smoke sensor plus wirelessly controllable indoor siren. The smoke detector is certified by the VdS for Q quality and DIN EN 14604 and satisfies all contemporary legal requirements.
The High-End 10 years smoke detector offers a test button conveniently accessible even with a broomstick when mounted on the sealing. The smoke chamber is monitored electronically to avoid any malfunction and wrong alerts. The device will also report its end of life to make sure it is getting replaced on time.
According to the VdS 3515 (smoke sensors with radio communication) this device will relay all alarms to all other smoke sensors in the Z-Wave network to create a house-wide alarm. This connection of the smoke sensors is fully automated and needs no further configuration. The smoke sensors and the controller communicate via a secure protocol to prevent manipulation.
- Pressing the button 'Inclusion Button' for one second includes the device.
- If the button is pressed for at least 2 seconds the inclusion will be done without the Security Command Class
A single click on the button 'Inclusion Button' will exclude the device.
The following table summarises the channels available for the 009402 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Smoke Alarm | alarm_smoke | alarm_smoke | Smoke | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if a smoke is triggered.
The alarm_smoke
channel is of type alarm_smoke
and supports the Switch
item and is in the Smoke
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 4 configuration parameters available in the 009402. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Siren alarm sequence interval | Siren alarm sequence interval |
2 | Siren alarm tone length | Siren alarm tone length |
3 | Value of On-Command | |
4 | Value of Off-Command |
Siren alarm sequence interval The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off.
This parameter defines the total length of the interval in seconds. Values in the range 3 to 129 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Siren alarm tone length The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off.
This parameter defines the total length of the sound versus silence within this interval. Values in the range 1 to 99 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Values in the range 0 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 009402 supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 4 nodes.
Association group 2 supports 4 nodes.
Association group 3 supports 4 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | Linked to BASIC |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.