ZMNHOD - ZWave

{% include base.html %}

ZMNHOD Flush Shutter DC

This describes the Z-Wave device ZMNHOD, manufactured by Goap with the thing type UID of qubino_zmnhod_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

ZMNHOD product image

The ZMNHOD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This Z-Wave module is used to control the motor of blinds, rollers, shades, venetian blinds, etc.. The module can be controlled either through a Z-Wave network or through the wall switch.

Inclusion Information

  • press service button S for more than 2 second or
  • press push button I1 three times within 3s (3 times change switch state within 3 seconds)

Exclusion Information

  • press service button S for more than 6 second or
  • press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply.

Channels

The following table summarises the channels available for the ZMNHOD -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Blinds control blinds_control blinds_control Blinds Rollershutter
Binary Sensor sensor_binary sensor_binary Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Switch 1 switch_binary1 switch_binary Switch Switch
Blinds control 1 blinds_control1 blinds_control Blinds Rollershutter
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number:Temperature

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Blinds control

Provides start / stop control of blinds.

The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Blinds control 1

Provides start / stop control of blinds.

The blinds_control1 channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 14 configuration parameters available in the ZMNHOD. Detailed information on each parameter can be found in the sections below.

Param Name Description
10 Activate/deactivate functions ALL ON / ALL OFF Activate/deactivate functions ALL ON / ALL OFF
40 Power report (Watts) on power change for Q1 or Q2 Power report (Watts) on power change for Q1 or Q2
42 Power report (Watts) by time interval for Q1 or Q2 Power report (Watts) by time interval for Q1 or Q2
71 Operating modes Operating modes
72 Slats tilting full turn time Slats tilting full turn time
73 Slats position Slats position
74 Motor moving up/down time Motor moving up/down time
76 Motor operation detection Motor operation detection
78 Forced Shutter DC calibration Forced Shutter DC calibration
85 Power consumption max delay time Power consumption max delay time
86 Power consumption at limit switch delay time Power consumption at limit switch delay time
90 Time delay for next motor movement Time delay for next motor movement
110 Temperature sensor offset settings Temperature sensor offset settings
120 Digital temperature sensor reporting Digital temperature sensor reporting
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 10: Activate/deactivate functions ALL ON / ALL OFF

Activate/deactivate functions ALL ON / ALL OFF Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controllerbelonging to the system. The following option values may be configured -:

Value Description
0 ALL ON is not active, ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON is not active ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 40: Power report (Watts) on power change for Q1 or Q2

Power report (Watts) on power change for Q1 or Q2 Set value means percentage, set value from 0 – 100 = 0% - 100%.

Available configuration parameters 

  • default value 1
  • 0 - reporting disabled
  • 1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.  Values in the range 0 to 100 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 42: Power report (Watts) by time interval for Q1 or Q2

Power report (Watts) by time interval for Q1 or Q2 Set value means time interval (0 – 32767) in seconds, when power report is send.

Available configuration parameters

  • default value 300 = 300s
  • 0 - Reporting Disabled
  • 1 - 32767 = 1 second - 32767 seconds. Reporting enabled, power report is send with time interval set by entered value.  Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 71: Operating modes

Operating modes This parameter defines selection between two available operating modes.

Available configuration parameters 

  • default value 0
  • 0 - Shutter mode
  • 1 - venetian mode (up/down and slate rotation)

NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module! The following option values may be configured -:

Value Description
0 Shutter mode.
1 Venetian mode (up/down and slate rotation)

The manufacturer defined default value is 0 (Shutter mode.).

This parameter has the configuration ID config_71_1 and is of type INTEGER.

Parameter 72: Slats tilting full turn time

Slats tilting full turn time This parameter defines the time necessary for slats to make full turn (180 degrees).

Available configuration parameters 

  • default value 150 = 1,5 seconds
  • 0 - tilting time disabled
  • 1 - 32767 = 0,01seconds - 327,67 seconds

NOTE: If time set is too high, this will result that after full turn, Shutter will start move up/down, for time remaining.  Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 150.

This parameter has the configuration ID config_72_2 and is of type INTEGER.

Parameter 73: Slats position

Slats position This parameter defines slats position after up/down movement through Z-wave or push-buttons. The following option values may be configured -:

Value Description
0 Return to previous position only with Z-wave
1 Return to previous position with Z-wave or button

The manufacturer defined default value is 1 (Return to previous position with Z-wave or button).

This parameter has the configuration ID config_73_1 and is of type INTEGER.

Parameter 74: Motor moving up/down time

Motor moving up/down time This parameter defines Shutter motor moving time of complete opening or complete closing.

Available configuration parameters

  • default value 0
  • 0 - moving time disabled (working with limit switches)
  • 1 - 32767 = 0,1seconds - 3276,7seconds. After that time motor is stopped (relay goes to off state)

NOTE: Important is that the reference position to manually set moving time is always Shutter lower position! Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_74_2 and is of type INTEGER.

Parameter 76: Motor operation detection

Motor operation detection Power threshold to be interpreted when motor reach the limit switch.

Available configuration parameters

  •  default value 6 = 0,6W
  • 5 - 100 (0,5W - 10W), step is 0,1W.

NOTE: Motors with power consumption less than 0,5W could not be auto calibrated. In that case set time manually (par. 74). Values in the range 0 to 100 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_76_1 and is of type INTEGER.

Parameter 78: Forced Shutter DC calibration

Forced Shutter DC calibration By modifying the parameters setting from 0 to 1 a Shutter DC module enters the calibration mode.

Available configuration parameters 

  • default value 0
  • 1 - Start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0 The following option values may be configured -:
Value Description
0 Default
1 Start calibration process.

The manufacturer defined default value is 0 (Default).

This parameter has the configuration ID config_78_1 and is of type INTEGER.

Parameter 85: Power consumption max delay time

Power consumption max delay time This parameter defines the max time before motor power consumption is read after one of the relays is switched ON. If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, motor in end position,...) the relay will switch OFF. Time is defined by entering it manually.

Available configuration parameters

  • default value 8 = 800ms
  • 3 - 50 = 0,3seconds - 5seconds (100ms resolution) Values in the range 3 to 50 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_85_1 and is of type INTEGER.

Parameter 86: Power consumption at limit switch delay time

Power consumption at limit switch delay time This parameter defines the max time at limit switch, when power consumption is below power threshold. If the power consumption during this time is below power threshold (par. 76), the active output will switch off, means that limit switch is reached.

Available configuration parameters 

  • default value 8 = 800ms
  • 3 - 50 = 0,3seconds - 5seconds (100ms resolution)  Values in the range 3 to 50 may be set.

The manufacturer defined default value is 8.

This parameter has the configuration ID config_86_1 and is of type INTEGER.

Parameter 90: Time delay for next motor movement

Time delay for next motor movement This parameter defines the minimum time delay between next motor movement (minimum time between switching motor off and on again).

Available configuration parameters 

  • default value 5 = 500ms
  • 1 - 30 = 0,1seconds - 3seconds (100ms resolution) Values in the range 1 to 30 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_90_1 and is of type INTEGER.

Parameter 110: Temperature sensor offset settings

Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor.

Available configuration parameters

  • default value 32536  32536 - offset is 0.0C
  • From 1 to 100 - value from 0.1 °C to 10.0 °C is added to actual measured temperature.
  • From 1001 to 1100 - value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature. Values in the range 1 to 32536 may be set.

The manufacturer defined default value is 32536.

This parameter has the configuration ID config_110_2 and is of type INTEGER.

Parameter 120: Digital temperature sensor reporting

Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.

Available configuration parameters (data type is 1 Byte DEC):

  • Default value 5 = 0,5°C
  • 0 - reporting disabled
  • 1-127 = 0,1°C - 12,7°C, step is 0,1°C Values in the range 0 to 127 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHOD supports 9 association groups.

Group 1: Default reporting group

Association group 1 supports 1 node.

Group 2: Basic on/off - input I1

Triggered at change of the input I1 state and reflecting its state

Association group 2 supports 16 nodes.

Group 3: Basic on/off - input I2

Triggered at change of the input I2 state and reflecting its state

Association group 3 supports 16 nodes.

Group 4: Basic on/off - direction of roller

Triggered at sensing moving direction of roller up=FF, down=0

Association group 4 supports 16 nodes.

Group 5: Basic on/off - roller position

Triggered at reaching roller position bottom=FF, top=0

Association group 5 supports 16 nodes.

Group 6: Basic on/off

Triggered at reaching roller position bottom=FF, not bottom=0

Association group 6 supports 16 nodes.

Group 7: Multilevel set

triggered at changes of value of the Flush Shutter DC position

Association group 7 supports 16 nodes.

Group 8: Multilevel set

Triggered at changes of value of slats tilting position

Association group 8 supports 16 nodes.

Group 9: Multilevel sensor report

Triggered at change of temperature sensor

Association group 9 supports 16 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1