This describes the Z-Wave device ZDM-80, manufactured by Remotec with the thing type UID of remotec_adt8021_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The ZDM-80 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Dimming Module
Triple click the PROG button within 1 second.
The following table summarises the channels available for the ZDM-80 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
The following table provides a summary of the 6 configuration parameters available in the ZDM-80. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | All On/All Off | All On/All Off |
5 | Switch state after power failure | Switch state after power failure |
13 | Double click option | Double click option |
17 | Dimming time frame | Dimming time frame |
18 | Maximum Dimmer level control | Maximum Dimmer level control |
19 | Minimum Dimmer level control | Minimum Dimmer level control |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
All On/All Off
The following option values may be configured -:
Value | Description |
---|---|
-1 | All On active, All Off active |
0 | All On is not active, All Off is not active |
1 | All On is not active, All Off active |
2 | All On active, All Off is not active |
The manufacturer defined default value is -1
(All On active, All Off active).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Switch state after power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | Switch is OFF |
1 | Switch saves its state before power failure. |
The manufacturer defined default value is 1
(Switch saves its state before power failure.).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Double click option
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Dimming time frame Sets the time of moving the Dimmer from 0% to max. dimming values.
(The ZDM-80 will implement the dimming duration if received this parameter value from controller/gateway. Otherwise, the ZDM-80 will implement the local parameter value) Values in the range 0 to 5 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_17_1
and is of type INTEGER
.
Maximum Dimmer level control Define the upper dimming level. Higher percentages lead to higher brightness level. Values in the range 2 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_18_1
and is of type INTEGER
.
Minimum Dimmer level control Define the lower dimming level. Lower percentages lead to lower brightness level. Values in the range 1 to 98 may be set.
The manufacturer defined default value is 13
.
This parameter has the configuration ID config_19_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZDM-80 supports 2 association groups.
Association group_1 is used to report status change such as AUTO report to gateway.
Association group 1 supports 1 node.
ZDM-80 will send out related dimming level e.g. 50% by basic set command to its association group automatically when ZDM-80 received the dimming command by local switch or wireless command e.g. 50%.
ZDM-80 will send out related basic set command On (0xFF) or Off (0x00) to its association group automatically when ZDM-80 received On (0xFF) or Off (0x00) command by local switch or wireless command respectively. (Max. 4 nodes ID can be assigned to this association group)
Association group 2 supports 4 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V1 |