This describes the Z-Wave device CT110, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct110_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The CT110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The Z-Wave Plus enabled CT110 is a sleek, modern thermostat design for home automation systems. It’s clean user interface compliments app-enabled systems, and it connects to a Z-Wave network with one touch. The CT110 features adjustable real-time alerts to enable cloud triggers, a robust data stream of HVAC information for cloud monitoring, and configurable comfort response settings to customize home control scenes. The CT110 is compatible with all popular HVAC systems and is battery-operated without the need for a C-wire
Press and hold the network button for 5 seconds. The thermostat must be in OFF mode.
Press and hold the network button for 5 seconds. The thermostat must be in OFF mode.
The following table summarises the channels available for the CT110 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (furnace) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (dry air) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | thermostat_fanstate | ||
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset | time_offset | time_offset | Time | Number |
Sensor (temperature) 1 | sensor_temperature1 | sensor_temperature | Temperature | Number:Temperature |
Sensor (relative humidity) 1 | sensor_relhumidity1 | sensor_relhumidity | Humidity | Number |
Thermostat mode 1 | thermostat_mode1 | thermostat_mode | Temperature | Number |
Operating State 1 | thermostat_state1 | thermostat_state | Temperature | Number |
Setpoint (furnace) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (dry air) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (heating) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (cooling) 1 | thermostat_setpoint1 | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode 1 | thermostat_fanmode1 | thermostat_fanmode | ||
Thermostat fan state 1 | thermostat_fanstate1 | thermostat_fanstate | ||
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset 1 | time_offset1 | time_offset | Time | Number |
Sensor (temperature) 2 | sensor_temperature2 | sensor_temperature | Temperature | Number:Temperature |
Sensor (relative humidity) 2 | sensor_relhumidity2 | sensor_relhumidity | Humidity | Number |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity
channel is of type sensor_relhumidity
and supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
Indicates the current temperature.
The sensor_temperature1
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity1
channel is of type sensor_relhumidity
and supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Sets the thermostat.
The thermostat_mode1
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state1
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint1
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level1
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Provides the current time difference for the devices time.
The time_offset1
channel is of type time_offset
and supports the Number
item and is in the Time
category.
Indicates the current temperature.
The sensor_temperature2
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity2
channel is of type sensor_relhumidity
and supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 18 configuration parameters available in the CT110. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Temperature Reporting Threshold | Temperature Reporting Threshold |
2 | HVAC Type | HVAC Type |
2 | # of Auxiliary Stages | # of Auxiliary Stages |
2 | Fuel Type | Fuel Type |
2 | # of Heat Pump Stages. | # of Heat Pump Stages. |
2 | # of Cool Stages. | # of Cool Stages. |
3 | Utility Lock | Utility Lock |
4 | C-Wire/Battery | C-Wire/Battery |
5 | Humidity Reporting Threshold | Humidity Reporting Threshold |
6 | Auxiliary/Emergency Mode | Auxiliary/Emergency Mode |
7 | Thermostat Swing Temperature | Thermostat Swing Temperature |
9 | Thermostat Recovery Mode | Thermostat Recovery Mode |
10 | Temperature Reporting Filter (lower bound) | Temperature Reporting Filter (lower bound) |
10 | Temperature Reporting Filter (upper bound) | Temperature Reporting Filter (upper bound) |
11 | Simple UI Mode | Simple UI Mode |
12 | Multicast | Multicast |
13 | Main Display Settings | Main Display Settings |
14 | Save Energy Mode Type | Save Energy Mode Type |
Temperature Reporting Threshold
Values in the range 0 to 4 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
HVAC Type
The following option values may be configured -:
Value | Description |
---|---|
1 | Normal |
2 | Heat Pump |
The manufacturer defined default value is 1
(Normal).
This parameter has the configuration ID config_2_4_000000FF
and is of type INTEGER
.
# of Auxiliary Stages
Values in the range 0 to 64 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_4_00000F00
and is of type INTEGER
.
Fuel Type
The following option values may be configured -:
Value | Description |
---|---|
1 | Gas |
2 | Electric |
The manufacturer defined default value is 1
(Gas).
This parameter has the configuration ID config_2_4_0000F000
and is of type INTEGER
.
# of Heat Pump Stages.
Values in the range 0 to 128 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_4_00FF0000
and is of type INTEGER
.
# of Cool Stages.
Values in the range 0 to 64 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_4_0F000000
and is of type INTEGER
.
Utility Lock
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
255 | Enabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
C-Wire/Battery
The following option values may be configured -:
Value | Description |
---|---|
1 | C-Wire |
2 | Battery |
The manufacturer defined default value is 1
(C-Wire).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Humidity Reporting Threshold
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | 3% RH |
2 | 5% RH |
3 | 10% RH |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Auxiliary/Emergency Mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Thermostat Swing Temperature
The following option values may be configured -:
Value | Description |
---|---|
1 | 0.5ºF |
2 | 1.0ºF |
3 | 1.5ºF |
4 | 2.0ºF |
5 | 2.5ºF |
6 | 3.0ºF |
7 | 3.5ºF |
8 | 4.0ºF |
The manufacturer defined default value is 1
(0.5ºF).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Thermostat Recovery Mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Fast |
2 | Economy |
The manufacturer defined default value is 2
(Economy).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Temperature Reporting Filter (lower bound) 0 -124ºF (lower bound) Values in the range 0 to 124 may be set.
The manufacturer defined default value is 124
.
This parameter has the configuration ID config_10_2_0000FFFF
and is of type INTEGER
.
Temperature Reporting Filter (upper bound) 0-124ºF (upper bound) Values in the range 0 to 124 may be set.
The manufacturer defined default value is 124
.
This parameter has the configuration ID config_10_2_0FFF0000
and is of type INTEGER
.
Simple UI Mode
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal Mode |
1 | Simple Mode |
The manufacturer defined default value is 1
(Simple Mode).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Multicast
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Enabled |
The manufacturer defined default value is 1
(Enabled).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Main Display Settings
The following option values may be configured -:
Value | Description |
---|---|
1 | Temperature |
2 | Humidity |
The manufacturer defined default value is 1
(Temperature).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Save Energy Mode Type 1=Adjust by target delta,
2=Least consuming point in the running program,
3=Save energy absolute setpoint,
255=Save Energy not supported Values in the range 1 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
This is a read only parameter.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The CT110 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 2 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.