Skip to content

Latest commit

 

History

History
609 lines (404 loc) · 20.6 KB

ct110_0_0.md

File metadata and controls

609 lines (404 loc) · 20.6 KB
layout title
documentation
CT110 - ZWave

{% include base.html %}

CT110 Thermostat

This describes the Z-Wave device CT110, manufactured by Radio Thermostat Company of America (RTC) with the thing type UID of rtc_ct110_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

CT110 product image

The CT110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

The Z-Wave Plus enabled CT110 is a sleek, modern thermostat design for home automation systems. It’s clean user interface compliments app-enabled systems, and it connects to a Z-Wave network with one touch. The CT110 features adjustable real-time alerts to enable cloud triggers, a robust data stream of HVAC information for cloud monitoring, and configurable comfort response settings to customize home control scenes. The CT110 is compatible with all popular HVAC systems and is battery-operated without the need for a C-wire

Inclusion Information

Press and hold the network button for 5 seconds.  The thermostat must be in OFF mode.

Exclusion Information

Press and hold the network button for 5 seconds.  The thermostat must be in OFF mode.

Channels

The following table summarises the channels available for the CT110 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (furnace) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (dry air) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number
Sensor (temperature) 1 sensor_temperature1 sensor_temperature Temperature Number:Temperature
Sensor (relative humidity) 1 sensor_relhumidity1 sensor_relhumidity Humidity Number
Thermostat mode 1 thermostat_mode1 thermostat_mode Temperature Number
Operating State 1 thermostat_state1 thermostat_state Temperature Number
Setpoint (furnace) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Setpoint (dry air) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Setpoint (heating) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Setpoint (cooling) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Thermostat fan mode 1 thermostat_fanmode1 thermostat_fanmode
Thermostat fan state 1 thermostat_fanstate1 thermostat_fanstate
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset 1 time_offset1 time_offset Time Number
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number:Temperature
Sensor (relative humidity) 2 sensor_relhumidity2 sensor_relhumidity Humidity Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (furnace)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (dry air)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Sensor (temperature) 1

Indicates the current temperature.

The sensor_temperature1 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (relative humidity) 1

Indicates the current relative humidity.

The sensor_relhumidity1 channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode 1

Sets the thermostat.

The thermostat_mode1 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State 1

Sets the thermostat operating state.

The thermostat_state1 channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (furnace) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (dry air) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (cooling) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode 1

Channel type information on this channel is not found.

Thermostat fan state 1

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level1 channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset 1

Provides the current time difference for the devices time.

The time_offset1 channel is of type time_offset and supports the Number item and is in the Time category.

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (relative humidity) 2

Indicates the current relative humidity.

The sensor_relhumidity2 channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 18 configuration parameters available in the CT110. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Temperature Reporting Threshold Temperature Reporting Threshold
2 HVAC Type HVAC Type
2 # of Auxiliary Stages # of Auxiliary Stages
2 Fuel Type Fuel Type
2 # of Heat Pump Stages. # of Heat Pump Stages.
2 # of Cool Stages. # of Cool Stages.
3 Utility Lock Utility Lock
4 C-Wire/Battery C-Wire/Battery
5 Humidity Reporting Threshold Humidity Reporting Threshold
6 Auxiliary/Emergency Mode Auxiliary/Emergency Mode
7 Thermostat Swing Temperature Thermostat Swing Temperature
9 Thermostat Recovery Mode Thermostat Recovery Mode
10 Temperature Reporting Filter (lower bound) Temperature Reporting Filter (lower bound)
10 Temperature Reporting Filter (upper bound) Temperature Reporting Filter (upper bound)
11 Simple UI Mode Simple UI Mode
12 Multicast Multicast
13 Main Display Settings Main Display Settings
14 Save Energy Mode Type Save Energy Mode Type

Parameter 1: Temperature Reporting Threshold

Temperature Reporting Threshold

Values in the range 0 to 4 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: HVAC Type

HVAC Type

The following option values may be configured -:

Value Description
1 Normal
2 Heat Pump

The manufacturer defined default value is 1 (Normal).

This parameter has the configuration ID config_2_4_000000FF and is of type INTEGER.

Parameter 2: # of Auxiliary Stages

# of Auxiliary Stages

Values in the range 0 to 64 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_4_00000F00 and is of type INTEGER.

Parameter 2: Fuel Type

Fuel Type

The following option values may be configured -:

Value Description
1 Gas
2 Electric

The manufacturer defined default value is 1 (Gas).

This parameter has the configuration ID config_2_4_0000F000 and is of type INTEGER.

Parameter 2: # of Heat Pump Stages.

# of Heat Pump Stages.

Values in the range 0 to 128 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_4_00FF0000 and is of type INTEGER.

Parameter 2: # of Cool Stages.

# of Cool Stages.

Values in the range 0 to 64 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_4_0F000000 and is of type INTEGER.

Parameter 3: Utility Lock

Utility Lock

The following option values may be configured -:

Value Description
0 Disabled
255 Enabled

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: C-Wire/Battery

C-Wire/Battery

The following option values may be configured -:

Value Description
1 C-Wire
2 Battery

The manufacturer defined default value is 1 (C-Wire).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Humidity Reporting Threshold

Humidity Reporting Threshold

The following option values may be configured -:

Value Description
0 Disabled
1 3% RH
2 5% RH
3 10% RH

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Auxiliary/Emergency Mode

Auxiliary/Emergency Mode

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Thermostat Swing Temperature

Thermostat Swing Temperature

The following option values may be configured -:

Value Description
1 0.5ºF
2 1.0ºF
3 1.5ºF
4 2.0ºF
5 2.5ºF
6 3.0ºF
7 3.5ºF
8 4.0ºF

The manufacturer defined default value is 1 (0.5ºF).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 9: Thermostat Recovery Mode

Thermostat Recovery Mode

The following option values may be configured -:

Value Description
1 Fast
2 Economy

The manufacturer defined default value is 2 (Economy).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Temperature Reporting Filter (lower bound)

Temperature Reporting Filter (lower bound)  0 -124ºF (lower bound) Values in the range 0 to 124 may be set.

The manufacturer defined default value is 124.

This parameter has the configuration ID config_10_2_0000FFFF and is of type INTEGER.

Parameter 10: Temperature Reporting Filter (upper bound)

Temperature Reporting Filter (upper bound) 0-124ºF (upper bound) Values in the range 0 to 124 may be set.

The manufacturer defined default value is 124.

This parameter has the configuration ID config_10_2_0FFF0000 and is of type INTEGER.

Parameter 11: Simple UI Mode

Simple UI Mode

The following option values may be configured -:

Value Description
0 Normal Mode
1 Simple Mode

The manufacturer defined default value is 1 (Simple Mode).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Multicast

Multicast

The following option values may be configured -:

Value Description
0 Disabled
1 Enabled

The manufacturer defined default value is 1 (Enabled).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Main Display Settings

Main Display Settings

The following option values may be configured -:

Value Description
1 Temperature
2 Humidity

The manufacturer defined default value is 1 (Temperature).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Save Energy Mode Type

Save Energy Mode Type 1=Adjust by target delta,

2=Least consuming point in the running program,

3=Save energy absolute setpoint,

255=Save Energy not supported Values in the range 1 to 255 may be set.

The manufacturer defined default value is 255.

This parameter has the configuration ID config_14_1 and is of type INTEGER. This is a read only parameter.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The CT110 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 2 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_MODE_V2
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_MODE_V2
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.