NAS-AB01Z Siren Alarm

This describes the Z-Wave device NAS-AB01Z, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_nasab01z_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

NAS-AB01Z product image

The NAS-AB01Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

Siren Alarm with ten different sounds.

Inclusion Information

The siren alarm can be included to the Z-wave network by pressing on the code button.

  1. Disassemble the siren alarm and insert the battery into the siren alarm. Make sure the device is located within the direct range of the controller.
  2. Set the controller into the learning mode (see main controller’s operating manual).
  3. Quickly, triple click the code button, LED light will flash red.
  4. Siren alarm will be detected and included in the Z-Wave network.
  5. Wait for the main controller to configure the siren alarm.

Exclusion Information

  1. Make sure the sensor is connected to power source.
  2. Set the main controller into the learning mode (see main controller’s operating manual).
  3. Quickly, triple click the code button, LED light will flash red for 5 times.
  4. Wait for the main controller to delete the sensor.

Channels

The following table summarises the channels available for the NAS-AB01Z -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Siren ON Mode config_decimal config_decimal Number
Alarm alarm_general alarm_general Alarm Switch
Battery Level battery-level system.battery_level Battery Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Siren ON Mode

Configure default siren ON mode:

1 = Alarm Music Mode

2 = Door Bell Music

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the NAS-AB01Z. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Configure Alarm music volume Configure Alarm music volume
2 Alarm music duration time Alarm music duration time
3 Door bell music duration time Door bell music duration time
4 Door bell music volume Door bell music volume
5 Alarm music index Alarm music index
6 Door bell music index Door bell music index
7 Default Siren on mode Default Siren on mode
8 Alarm Led Enable Alarm Led Enable
9 Door Bell Led Enable Door Bell Led Enable

Parameter 1: Configure Alarm music volume

Configure Alarm music volume

Values in the range 1 to 3 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Alarm music duration time

Alarm music duration time

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Door bell music duration time

Door bell music duration time

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Door bell music volume

Door bell music volume

Values in the range 1 to 3 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Alarm music index

Alarm music index

Values in the range 1 to 10 may be set.

The manufacturer defined default value is 9.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Door bell music index

Door bell music index

Values in the range 1 to 10 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Default Siren on mode

Default Siren on mode This parameter defines the default music index, volume and duration time for siren on.

This parameter can be selected between ALARM MUSIC and DOOR BELL music.

The settings for ALARM MUSIC defines by Param #1, #2, #5.

The settings for DOOR BELL defines by Param #3, #4, #6. Values in the range 1 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Alarm Led Enable

Alarm Led Enable This parameter defines the default led enable status when siren is on for ALARM SOUND MODE. If parameter is set to ‘0’, led will be disable. If parameter is set to ‘1’, led will be enable. When siren is on, the led will blink. Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Door Bell Led Enable

Door Bell Led Enable This parameter defines the default led enable status when siren is on for DOOR BELL SOUND MODE.

If parameter is set to ‘0’, led will be disable.

If parameter is set t0 ‘1’, led will be enable. When siren is on, the led will blink. Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The NAS-AB01Z supports 3 association groups.

Group 1: Group 1

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Group 3: Group2

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links