10001020-13X Dimmer IO: Phase cut dimmer

This describes the Z-Wave device 10001020-13X, manufactured by SimonTech S.L.U with the thing type UID of simontech_1000102013x_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

10001020-13X product image

The 10001020-13X supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The electronic dimmer switch 230V ~ with 2/3 wire phase cut is a switch from Simon 100 serie. These types of dimmer switches have a power of 50W to 240W for traditional loads and 9W to 100W for LED loads. This is highly recommended for all types of uses (domestic, hotels, hospitals ...). The dimmer switch is only compatible with Simon 100 frames.

Inclusion Information

  1. Put controller into inclusion mode.
  2. When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to include the device to the Z-Wave network. Main LED will blink with 0,3 sec period.

Exclusion Information

  1. Put controller into exclusion mode.
  2. When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to include the device to the Z-Wave network. Main LED will blink with 0,3 sec period.

Channels

The following table summarises the channels available for the 10001020-13X -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Electric meter (watts) meter_watts meter_watts Energy Number

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 18 configuration parameters available in the 10001020-13X. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Association LED Association LED
4 Set time Set time
5 Fade time Fade time
6 Minimum dimming value Minimum dimming value
7 Maximum dimming value Maximum dimming value
8 Last on value Last on value
9 Calibration Calibration
10 Delay ON Delay ON
11 Activation time Activation time
12 Behavior of LED in repose Behavior of LED in repose
13 Lock input Lock input
15 Reset default Reset default
16 Delay OFF Delay OFF
19 Press action Press action
20 Identify Identify
21 State of charge State of charge
23 Calibration required Calibration required
27 Lock long press Lock long press

Parameter 1: Association LED

Association LED

The following option values may be configured -:

Value Description
0 Turns the main LED ON
255 Turns the main LED OFF

The manufacturer defined default value is 0 (Turns the main LED ON).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 4: Set time

Set time

<td>
  Instantly (default value) Disable timming
</td>
<td>
  1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
</td>
<td>
  1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution
</td>
0x00
0x01-0x7F
0x80-0xFE
Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Fade time

Fade time

<td>
  Instantly (default value) Disable timming
</td>
<td>
  1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
</td>
<td>
  1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution
</td>
0x00
0x01-0x7F
0x80-0xFE
Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Minimum dimming value

Minimum dimming value Stablishes the Max and Min percentages that can be reached. Once the devices gets a value through Z-Wave it Scales the value read according this Min and Max margins. Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Maximum dimming value

Maximum dimming value Stablishes the Max and Min percentages that can be reached. Once the devices gets a value through Z-Wave it Scales the value read according this Min and Max margins. Values in the range 1 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Last on value

Last on value Returns or sets the last non zero dimming value. In case of Set the device turns ON the load. Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Calibration

Calibration

The following option values may be configured -:

Value Description
1 Smart Calibrate
2 Device is calibrated using Trailing Edge
3 Device is calibrated using Leading Edge

The manufacturer defined default value is 1 (Smart Calibrate).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Delay ON

Delay ON

<td>
  Instantly (default value) Disable timming
</td>
<td>
  1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
</td>
<td>
  1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution
</td>
0x00
0x01-0x7F
0x80-0xFE
Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Activation time

Activation time

<td>
  Instantly (default value) Disable timming
</td>
<td>
  1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
</td>
<td>
  1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution
</td>
0x00
0x01-0x7F
0x80-0xFE
Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Behavior of LED in repose

Behavior of LED in repose

The following option values may be configured -:

Value Description
0 LED OFF
255 Central LED on at 20% of maximum level

The manufacturer defined default value is 0 (LED OFF).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Lock input

Lock input

The following option values may be configured -:

Value Description
0 Unlock the direct control of load
255 Lock the direct control of load

The manufacturer defined default value is 0 (Unlock the direct control of load).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 15: Reset default

Reset default

The following option values may be configured -:

Value Description
17170 Soft reset
39015 Hard reset

The manufacturer defined default value is 17170 (Soft reset).

This parameter has the configuration ID config_15_2_wo and is of type INTEGER. This is a write only parameter.

Parameter 16: Delay OFF

Delay OFF

<td>
  Instantly (default value) Disable timming
</td>
<td>
  1 second (0x01) to 127 seconds (0x7F) in 1 second resolution
</td>
<td>
  1 second (0x80) to 127 minutes (0xFE) in 1 minute resolution
</td>
0x00
0x01-0x7F
0x80-0xFE
Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 19: Press action

Press action

The following option values may be configured -:

Value Description
0 Device toggles the load
1 Device turns ON the load
2 Device turns OFF the load
4 Device turns the load ON and then OFF
5 Device toggles the load and dims

The manufacturer defined default value is 5 (Device toggles the load and dims).

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: Identify

Identify The central LED blinks for 5 seconds in order to identify the device. The following option values may be configured -:

Value Description
255 The dimmer blinks

The manufacturer defined default value is 255 (The dimmer blinks).

This parameter has the configuration ID config_20_1_wo and is of type INTEGER. This is a write only parameter.

Parameter 21: State of charge

State of charge

<td>
  <p>
    0x00 Load is OFF
  </p>
  
  <p>
    0x01 Load is ON
  </p>
</td>
<td>
  0x00 - 0x063 Last active dimming value
</td>
First byte
Second byte
Values in the range 0 to 65379 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_21_2 and is of type INTEGER. This is a read only parameter.

Parameter 23: Calibration required

Calibration required

The following option values may be configured -:

Value Description
0 Calibration not required
255 Calibration required

The manufacturer defined default value is 0 (Calibration not required).

This parameter has the configuration ID config_23_1 and is of type INTEGER. This is a read only parameter.

Parameter 27: Lock long press

Lock long press

The following option values may be configured -:

Value Description
0 Default long press
255 Options

The manufacturer defined default value is 0 (Default long press).

This parameter has the configuration ID config_27_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 10001020-13X supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. On/Off Report when load state is changed:

  • On -> CC Basic, Basic Report, Value 0x01 - 0x63 Report the dimming level
  • Off -> CC Basic, Basic Report, Value 0x00

Instant Power Consumption vary over 10% and is stable almost 2sec:

  • CC Meter, Meter Report, “Electric meter”, “Consumed”, “Watts”, Size 4, Precision 1, Value (W)

Calibration requirement change. (If device needs to be calibrated and is Added into a Z-Wave network, it will report after receive an Association Set of life line).

  • Calibration required -> CC Configuration, Configuration Report, Param 23, Value 0xFF
  • Calibration not required -> CC Configuration, Configuration Report, Param 23, Value 0x00

After reset the Z-Wave module, a DEVICE-RESET-LOCALLY-NOTIFICATION is sent.

Association group 1 supports 3 nodes.

Group 2: CTRL

On/Off Report when load state is changed:

  • On -> CC Basic, Basic Report, Value 0x01 - 0x63 Report the dimming level
  • Off -> CC Basic, Basic Report, Value 0x00

Association group 2 supports 20 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.