Skip to content

Latest commit

 

History

History
249 lines (145 loc) · 8.48 KB

veggplug_0_0.md

File metadata and controls

249 lines (145 loc) · 8.48 KB
layout title
documentation
VEGGPLUG - ZWave

{% include base.html %}

VEGGPLUG NAMRON Smart Plug

This describes the Z-Wave device VEGGPLUG, manufactured by Sunricher with the thing type UID of sunricher_veggplug_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

VEGGPLUG product image

The VEGGPLUG supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Zwave Smart Plug

Inclusion Information

Press and hold down action button for 10 seconds

Exclusion Information

Triple click the action button

Channels

The following table summarises the channels available for the VEGGPLUG -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Alarm (power) alarm_power alarm_power Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the VEGGPLUG. Detailed information on each parameter can be found in the sections below.

Param Name Description
12 Percentage Threshold Level Percentage Threshold Level
13 Absolute Value Threshold Level Absolute Value Threshold Level
14 Time Interval Report Voltage Time Interval Report Voltage
15 Time Interval Report Current Time Interval Report Current
16 Time Interval Report Power Time Interval Report Power
17 Time Interval Report Energy Time Interval Report Energy
18 Saving load state before power failure Saving load state before power failure
19 Enable/Disable Switch Binary Report Enable/Disable Switch Binary Report
20 Enable/Disable Current Protection Function Enable/Disable Current Protection Function

Parameter 12: Percentage Threshold Level

Percentage Threshold Level

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Absolute Value Threshold Level

Absolute Value Threshold Level

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_2 and is of type INTEGER.

Parameter 14: Time Interval Report Voltage

Time Interval Report Voltage

Values in the range 0 to 2678400 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_4 and is of type INTEGER.

Parameter 15: Time Interval Report Current

Time Interval Report Current

Values in the range 0 to 2678400 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_15_4 and is of type INTEGER.

Parameter 16: Time Interval Report Power

Time Interval Report Power

Values in the range 0 to 2678400 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_16_4 and is of type INTEGER.

Parameter 17: Time Interval Report Energy

Time Interval Report Energy

Values in the range 0 to 2678400 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_17_4 and is of type INTEGER.

Parameter 18: Saving load state before power failure

Saving load state before power failure

Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: Enable/Disable Switch Binary Report

Enable/Disable Switch Binary Report

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: Enable/Disable Current Protection Function

Enable/Disable Current Protection Function

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The VEGGPLUG supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.