ZV-9101 In-Wall Dimmer Module

This describes the Z-Wave device ZV-9101, manufactured by Sunricher with the thing type UID of sunricher_zv9101pushdim_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZV-9101 product image

The ZV-9101 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave Built-in receiver with dimmer function. Control input, AC 230V / DC 12V, for Pushdim. Max 400 W resistive load, 200 W LED. Front edge / Rear dimmer, adjustable lowest level. Compatible with Nexa Bridge and other Z-Wave controllers.

Inclusion Information

  • Press the "Reset" button 3 times within 3 seconds or
  • press 3 times on connected switch within 3 seconds

Exclusion Information

  • Set the Z-Wave controller in the exclusion mode (see controller's manual)
  • Press the "Reset" button 3 times within 3 seconds

General Usage Information

Control with retractive switch: Press once to turn on. Press again to turn off. To dim, keep the button pressed in when the light is on. The light comes on with the luminance it had when it was turned off.

Channels

The following table summarises the channels available for the ZV-9101 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number
Alarm (system) alarm_system alarm_system Switch

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Alarm (system)

Indicates if a system alarm is triggered.

The alarm_system channel is of type alarm_system and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the ZV-9101. Detailed information on each parameter can be found in the sections below.

Param Name Description
2 Saving load state Saving load state before power failure
3 Enable/disable to send report basic report to the Lifeline when the load state changed
4 Default fade time Default fade time (unit is second)
5 brightness value Setting minimum brightness value
6 MOSFET Choose MOSFET
7 removal from network Enable/disable external switch to be added to and removed from a network

Parameter 2: Saving load state

Saving load state before power failure Info: Saving load state before power failure 0 – shutoff load 1 – turn on load 2 – save load state before power failure Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Enable/disable to send report

basic report to the Lifeline when the load state changed Enable/disable to send the basic report to the Lifeline when the load state changed (When value set as 1, re-power on the dimmer, it will send Basic report automatically)

0 – Disable to send Basic report

1 – Enable to send Basic report Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Default fade time

Default fade time (unit is second) Default fade time (unit is second, this value has the same function as Duration of Multilevel) Valid value: 0x00 - 0xFF

<td>
  Description
</td>
<td>
  1 second to 127 seconds in 1 second resolution
</td>
<td>
  1 minute to 127 minutes in 1 minute resolution
</td>
<td>
  Factory default duration. (1 sec.)
</td>
Value
0-127
128-254
255
Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: brightness value

Setting minimum brightness value Setting minimum brightness value Valid value: 0 - 50, the bigger the value is, the higher the load’s minimum brightness is Note: when configure this value, the value of Multilevel will be configured as 1 automatically so that users can preview the corre-sponding effect of minimum brightness value Values in the range 0 to 50 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: MOSFET

Choose MOSFET Choose MOSFET driving type 0 – trailing edge 1 – leading edge Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: removal from network

Enable/disable external switch to be added to and removed from a network Enable/disable external switch to be added to and removed from a network (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a net-work) 0 – disable 1 - enable Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZV-9101 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Emergency Shutoff The dimmer has accounted for Emergency Shutoff, when the temperature rises above 90°C, Emergency Shutoff is sent to Lifeline.

System (0x09) Emergency Shutoff status

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.