This describes the Z-Wave device TechniSat Shutter, manufactured by Technisat with the thing type UID of technisat_shutter_00_000
.
The device is in the category of Blinds, defining Roller shutters, window blinds, etc..
The TechniSat Shutter supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
TechniSat roller shutter is a wall switch to control window roller shutters via Z-Wave. At the same time, the roller shutters can still be operated manually via the switch. Furthermore, the power consumption can be determined.
The roller shutter switch is installed in standard flush-mounted boxes
Press the upper position of the left button (T1) 3x within a second.
Press and hold the upper position of the left button (T1) for at least 10 seconds when the shutter is in the top position.
The following table summarises the channels available for the TechniSat Shutter -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Blinds Control | blinds_control | blinds_control | Blinds | Rollershutter |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Meter reset | meter_reset | meter_reset | Energy | Switch |
Scene Number | scene_number | scene_number | Number | |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Provides start / stop control of blinds.
The blinds_control
channel is of type blinds_control
and supports the Rollershutter
item and is in the Blinds
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 4 configuration parameters available in the TechniSat Shutter. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Central scene notification | Enable/Disable Central scene notifcations for 2x-5x press |
2 | Wattage meter | Interval Current wattage meter report in 10s |
3 | Energy meter report | Interval of active energy meter report in minutes |
4 | Manual shutter calibration | Manual shutter calibration |
Enable/Disable Central scene notifcations for 2x-5x press 0 - disable, 1 - enable Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Interval Current wattage meter report in 10s Interval of current wattage meter report in 10 second steps, 30s ... 1day, 0 - disable Values in the range 0 to 8640 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Interval of active energy meter report in minutes Interval of active energy meter report in minutes, 10min ... 3 weeks, 0 - disable Values in the range 0 to 30240 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
Manual shutter calibration
Manual shutter calibration (shutter will move up, down and up again)
0 - idle, 1 - start a manual shutter calibration
Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TechniSat Shutter supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
- Device Reset Locally Notification
- Central Scene notification
- Meter Report
- Multilevel Switch Report
- Notification Report
Association group 1 supports 1 node.
Basic Set
Association group 2 supports 10 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V2 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V4 | Linked to BASIC |
COMMAND_CLASS_METER_V4 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V3 | |
COMMAND_CLASS_SECURITY_V1 |