TechniSat Shutter Shutter wall switch

This describes the Z-Wave device TechniSat Shutter, manufactured by Technisat with the thing type UID of technisat_shutter_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

TechniSat Shutter product image

The TechniSat Shutter supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

TechniSat roller shutter is a wall switch to control window roller shutters via Z-Wave. At the same time, the roller shutters can still be operated manually via the switch. Furthermore, the power consumption can be determined.

The roller shutter switch is installed in standard flush-mounted boxes

Inclusion Information

Press the upper position of the left button (T1) 3x within a second.

Exclusion Information

Press and hold the upper position of the left button (T1) for at least 10 seconds when the shutter is in the top position.

Channels

The following table summarises the channels available for the TechniSat Shutter -:

Channel Name Channel ID Channel Type Category Item Type
Blinds Control blinds_control blinds_control Blinds Rollershutter
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Meter reset meter_reset meter_reset Energy Switch
Scene Number scene_number scene_number Number
Alarm (power) alarm_power alarm_power Energy Switch

Blinds Control

Provides start / stop control of blinds.

The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Meter reset

Reset the meter.

The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the TechniSat Shutter. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Central scene notification Enable/Disable Central scene notifcations for 2x-5x press
2 Wattage meter Interval Current wattage meter report in 10s
3 Energy meter report Interval of active energy meter report in minutes
4 Manual shutter calibration Manual shutter calibration

Parameter 1: Central scene notification

Enable/Disable Central scene notifcations for 2x-5x press 0 - disable, 1 - enable Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Wattage meter

Interval Current wattage meter report in 10s Interval of current wattage meter report in 10 second steps, 30s ... 1day, 0 - disable Values in the range 0 to 8640 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Energy meter report

Interval of active energy meter report in minutes Interval of active energy meter report in minutes, 10min ... 3 weeks, 0 - disable Values in the range 0 to 30240 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Manual shutter calibration

Manual shutter calibration Manual shutter calibration (shutter will move up, down and up again)
0 - idle, 1 - start a manual shutter calibration Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TechniSat Shutter supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

  • Device Reset Locally Notification
  • Central Scene notification
  • Meter Report
  • Multilevel Switch Report
  • Notification Report

Association group 1 supports 1 node.

Group 2: Switch State

Basic Set

Association group 2 supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V2
COMMAND_CLASS_SWITCH_MULTILEVEL_V4 Linked to BASIC
COMMAND_CLASS_METER_V4
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_SECURITY_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.