HEATIT Z-TRM3 Floor thermostat

This describes the Z-Wave device HEATIT Z-TRM3, manufactured by ThermoFloor with the thing type UID of thermofloor_ztrm3_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

HEATIT Z-TRM3 product image

The HEATIT Z-TRM3 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

FEATURES

  • Floor sensor
  • Internal room sensor
  • External room sensor (connected by cable)
  • Temperature limiter
  • SmartStart
  • Weekly program/setback via gateway
  • Temperature read out in gateway
  • Firmware update (OTA)
  • Power metering
  • Relay status LED
  • Single pole switch
  • Lock mode/child lock
  • Calibration
  • 5 associations
  • Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class

Inclusion Information

  1. Press Center (confirm) for 10 seconds. The display will show OFF. 2. Press Right (down) 5 times until you see Con on the display.3. Start the add/remove device process in your primary controller.4. Start the add/remove mode in the Heatit Z-TRM3 by pressing Center (confirm) for approximately 2 seconds. Adding/removing mode is indicated on the display by rotating LED segments on the display. This lasts until the timeout occurs after 90 seconds, or until the module has been added/removed in the network. Confirmation will show Inc/EcL on the display. Exit programming mode by choosing ESC in the menu. Your thermostat is now ready for use with default settings

Exclusion Information

  1. Press Center (confirm) for 10 seconds. The display will show OFF. 2. Press Right (down) 5 times until you see Con on the display.3. Start the add/remove device process in your primary controller.4. Start the add/remove mode in the Heatit Z-TRM3 by pressing Center (confirm) for approximately 2 seconds. Adding/removing mode is indicated on the display by rotating LED segments on the display. This lasts until the timeout occurs after 90 seconds, or until the module has been added/removed in the network. Confirmation will show Inc/EcL on the display. Exit programming mode by choosing ESC in the menu. Your thermostat is now ready for use with default settings.NB! When the thermostat is removed from the gateway, the parameters are not reset. To reset the parameters, see Chapter 7: ”Factory reset”. If adding/removing fails, Err (error) will appear. Please perform a ”remove device” process and try again. If Err displays again, please see Chapter 7: “Factory reset”.

Channels

The following table summarises the channels available for the HEATIT Z-TRM3 -:

Channel Name Channel ID Channel Type Category Item Type
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Thermostat mode 1 thermostat_mode1 thermostat_mode Temperature Number
Operating State 1 thermostat_state1 thermostat_state Temperature Number
Setpoint (heating) 1 thermostat_setpoint1 thermostat_setpoint Heating Number:Temperature
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number:Temperature
Sensor (temperature) 3 sensor_temperature3 sensor_temperature Temperature Number:Temperature
Sensor (temperature) 4 sensor_temperature4 sensor_temperature Temperature Number:Temperature

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts) 1

Indicates the instantaneous voltage.

The meter_voltage1 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode 1

Sets the thermostat.

The thermostat_mode1 channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State 1

Sets the thermostat operating state.

The thermostat_state1 channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating) 1

Sets the thermostat setpoint.

The thermostat_setpoint1 channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (temperature) 3

Indicates the current temperature.

The sensor_temperature3 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (temperature) 4

Indicates the current temperature.

The sensor_temperature4 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 21 configuration parameters available in the HEATIT Z-TRM3. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Operation mode Operation mode
2 Sensor Mode Sensor Mode
3 Floor Sensor Type Floor Sensor Type
4 Temperature Control Hysteresis Temperature Control Hysteresis
5 Floor Minimum Temperature Limit Floor Minimum Temperature Limit
6 Floor MaximumTemperature Limit Floor MaximumTemperature Limit
7 Air Minimum Temp Limit (ALo) Air Minimum Temp Limit (ALo)
8 Air Maximum Temp Limit (AHi) Air Maximum Temp Limit (AHi)
9 Heating Mode Setpoint Heating Mode Setpoint
10 Room Sensor Calibration Room Sensor Calibration
11 Floor Sensor Calibration Floor Sensor Calibration
12 External Sensor Calibration External Sensor Calibration
13 Temperature Display Temperature Display
14 Button brighness dimmed state Button brighness dimmed state
15 Button brighness active state Button brighness active state
16 Display brighness dimmed state Display brighness dimmed state
17 Display brighness active state Display brighness active state
18 Temperature report interval Temperature report interval
19 Temperature report hysteresis Temperature report hysteresis
20 Meter report interval Meter report interval
21 Meter report delta value Meter report delta value

Parameter 1: Operation mode

Operation mode Value = 0, Off 
Value = 1, Heating mode, (default) The following option values may be configured -:

Value Description
0 Off
1 Heating mode

The manufacturer defined default value is 1 (Heating mode).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Sensor Mode

Sensor Mode

The following option values may be configured -:

Value Description
0 F-mode, floor sensor mode
1 A-mode, internal room sensor mode
2 AF-mode, internal roomsensor with floor limitation
3 A2-mode, external room sensor mode
4 A2F-mode, external sensor with floor limitation

The manufacturer defined default value is 1 (A-mode, internal room sensor mode).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Floor Sensor Type

Floor Sensor Type

The following option values may be configured -:

Value Description
0 10K NTC
1 12K NTC
2 15K NTC
3 22K NTC
4 33K NTC
5 47K NTC

The manufacturer defined default value is 0 (10K NTC).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Temperature Control Hysteresis

Temperature Control Hysteresis 0.3°C to 3.0°C. Default is 5 (0.5°C) Values in the range 3 to 30 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Floor Minimum Temperature Limit

Floor Minimum Temperature Limit 5.0°C to 40.0°C. Default is 50 (5.0°C) Values in the range 50 to 400 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Floor MaximumTemperature Limit

Floor MaximumTemperature Limit 5.0°C to 40.0°C. Default is 400 (40.0°C) Values in the range 50 to 400 may be set.

The manufacturer defined default value is 400.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Air Minimum Temp Limit (ALo)

Air Minimum Temp Limit (ALo) 5.0°C to 40.0°C. Default is 50 (5.0°C) Values in the range 50 to 400 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: Air Maximum Temp Limit (AHi)

Air Maximum Temp Limit (AHi) 5.0°C to 40.0°C. Default is 400 (40.0°C) Values in the range 50 to 400 may be set.

The manufacturer defined default value is 400.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: Heating Mode Setpoint

Heating Mode Setpoint 5.0°C to 40.0°C. Default is 210 (21.0°C) Values in the range 50 to 400 may be set.

The manufacturer defined default value is 210.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: Room Sensor Calibration

Room Sensor Calibration -6.0°C to 6.0°C. Default is 0 (0.0°C) Values in the range -60 to 60 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Floor Sensor Calibration

Floor Sensor Calibration -6.0°C to 6.0°C. Default is 0 (0.0°C) Values in the range -60 to 60 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: External Sensor Calibration

External Sensor Calibration -6.0°C to 6.0°C. Default is 0 (0.0°C) Values in the range -60 to 60 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Temperature Display

Temperature Display Selects which temperature is shown on the display. Refer to Chapter 11 ”Standby and main screen”. The following option values may be configured -:

Value Description
0 Display setpoint temperature (Default)
1 Display measured temperature

The manufacturer defined default value is 0 (Display setpoint temperature (Default)).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Button brighness dimmed state

Button brighness dimmed state Configure the brightness of the buttons in dimmed state.

0 to 100% (Default 50%) Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Button brighness active state

Button brighness active state Configure the brightness of the buttons in active state.

0 to 100% (Default 100%) Values in the range 0 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: Display brighness dimmed state

Display brighness dimmed state Configure the brightness of the display in dimmed state.

0 to 100% (Default 100%)   Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Display brighness active state

Display brighness active state Configure the brightness of the display, in active state.

0 to 100% (Default 100%)   Values in the range 0 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: Temperature report interval

Temperature report interval Time interval between consecutive temperature reports.

Temperature reports can also be sent as a result of polling.

30 seconds to 32767 seconds. Default is 60 seconds   Values in the range 30 to 32767 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_18_2 and is of type INTEGER.

Parameter 19: Temperature report hysteresis

Temperature report hysteresis The temperature report will be sent if there is a difference in temperature value from the previous value reported, defined in this parameter (hysteresis). Temperature reports can also be sent as a result of polling.

0.1°C to 10.0°C. Default is 10 (1.0°C)   Values in the range 1 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: Meter report interval

Meter report interval Time interval between consecutive meter reports.

Meter reports can also be sent as a result of polling.

30 seconds to 32767 seconds. Default is 90 seconds   Values in the range 30 to 32767 may be set.

The manufacturer defined default value is 90.

This parameter has the configuration ID config_20_2 and is of type INTEGER.

Parameter 21: Meter report delta value

Meter report delta value Delta value in kWh between consecutive meter reports. Meter reports can also be sent as a result of polling. The following option values may be configured -:

Value Description
0 Reporting meter based on change is disabled
10 A delta value of 0 to 25.5 kWh

The manufacturer defined default value is 10 (A delta value of 0 to 25.5 kWh ).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The HEATIT Z-TRM3 supports 5 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Relay State ON/OFF

Association group 2 supports 5 nodes.

Group 3: Internal Sensor

Association group 3 supports 5 nodes.

Group 4: External Sensor

Association group 4 supports 5 nodes.

Group 5: Floor Senosr

Association group 5 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 4

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3