layout | title |
---|---|
documentation |
TZE96 - ZWave |
{% include base.html %}
This describes the Z-Wave device TZE96, manufactured by TKB Home with the thing type UID of tkb_tze96_00_000
.
The device is in the category of Radiator Control, defining Controls on radiators used to heat up rooms.
The TZE96 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Thermostat TZE96 is a 230AC powered device which works in Z-Wave network. It is mounted on Wall with using electrical box. It has additional input for temperature sensor mounted in floor. Screen shows actual temperature in room or floor and clock. Thermostat has relay which could control load up to 16A (3600W). The possibility of defining the heating schedule. The ability to adjust the comfort mode, economy mode, party mode, holiday mode and control program mode.
- This model has a glass front and color touchscreen.
- Set contains cable temperature sensor for floor heating.
- Works in the newest standard Z-Wave Plus (500 series). Thermostat works fine with Fibaro (4.x firmware) and Vera gateways.
- Make sure the thermostat in the Main interface of OFF mode.
- Have z-wave controller enter inclusion mode.
- Press Up Button on thermostat 3 times in 1,5 seconds will enter inclusion mode.
- Make sure the thermostat in the Main interface of OFF mode.
- Have z-wave controller enter exclusion mode.
- Press Up Button on thermostat 3 times in 1,5 seconds will enter exclusion mode.
The following table summarises the channels available for the TZE96 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Clock Time Offset | time_offset | time_offset | Time | Number |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
The following table provides a summary of the 1 configuration parameters available in the TZE96. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
4 | Power failure | Remember device status before the power failure. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Remember device status before the power failure. This parameter determines how the TZE96 thermostat will react in the event of power supply failure (e.g. power outage or taking out from the electrical outlet). After the power supply is back on, the thermostat can be restored to previous state or remain switched off. The following option values may be configured -:
Value | Description |
---|---|
0 | Switched OFF |
1 | Restore state |
The manufacturer defined default value is 1
(Restore state).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TZE96 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |