TZE96 Color Touch Heating Thermostat

This describes the Z-Wave device TZE96, manufactured by TKB Home with the thing type UID of tkb_tze96_00_000.

The device is in the category of Radiator Control, defining Controls on radiators used to heat up rooms.

TZE96 product image

The TZE96 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Thermostat TZE96 is a 230AC powered device which works in Z-Wave network. It is mounted on Wall with using electrical box. It has additional input for temperature sensor mounted in floor. Screen shows actual temperature in room or floor and clock. Thermostat has relay which could control load up to 16A (3600W). The possibility of defining the heating schedule. The ability to adjust the comfort mode, economy mode, party mode, holiday mode and control program mode.

  • This model has a glass front and color touchscreen.
  • Set contains cable temperature sensor for floor heating.
  • Works in the newest standard Z-Wave Plus (500 series). Thermostat works fine with Fibaro (4.x firmware) and Vera gateways.

Inclusion Information

  1. Make sure the thermostat in the Main interface of OFF mode.
  2. Have z-wave controller enter inclusion mode.
  3. Press Up Button on thermostat 3 times in 1,5 seconds will enter inclusion mode.

Exclusion Information

  1. Make sure the thermostat in the Main interface of OFF mode.
  2. Have z-wave controller enter exclusion mode.
  3. Press Up Button on thermostat 3 times in 1,5 seconds will enter exclusion mode.

Channels

The following table summarises the channels available for the TZE96 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Clock Time Offset time_offset time_offset Time Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the TZE96. Detailed information on each parameter can be found in the sections below.

Param Name Description
4 Power failure Remember device status before the power failure.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 4: Power failure

Remember device status before the power failure. This parameter determines how the TZE96 thermostat will react in the event of power supply failure (e.g. power outage or taking out from the electrical outlet). After the power supply is back on, the thermostat can be restored to previous state or remain switched off.  The following option values may be configured -:

Value Description
0 Switched OFF
1 Restore state

The manufacturer defined default value is 1 (Restore state).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TZE96 supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links