Skip to content

Latest commit

 

History

History
183 lines (132 loc) · 5.97 KB

nzw97_0_0.md

File metadata and controls

183 lines (132 loc) · 5.97 KB
layout title
documentation
NZW97 - ZWave

{% include base.html %}

NZW97 Inovelli Outdoor Smart Plug (2 Channel)

This describes the Z-Wave device NZW97, manufactured by Willis Electric Co., Ltd. with the thing type UID of willis_nzw97_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

NZW97 product image

The NZW97 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

  • 2 Controllable Outlets
  • Outdoor IP65
  • 20 cm Cord
  • High Temp Protection (OFF at 105°C)
  • Last Power State (Possible DEFAULT)
  • 120 VAC, 60 Hz
  • 908.42 MHz
  • Max Load Outlet #1 1800W (15A) Resistive
  • Max Load Outlet #2 1800W (15A) Resistive
  • Max Simultaneous Load 15A
  • Max Range LoS 100 m
  • Operating Temperature Range -20°C to 50°C
  • UL E464831
  • FCC ID OXGZW97

Inclusion Information

  • Auto-Inclusion 30 sec from power on
  • Backup-Inclusion Press button 5 times within 1 sec
  • (Tested to work with Network Wide Inclusion)

Exclusion Information

Press the Middle Button on the front of your NZW97 five (5) times rapidly (within 1-2 seconds)

Channels

The following table summarises the channels available for the NZW97 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Alarm (heat) alarm_heat alarm_heat Fire Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Alarm (heat)

Indicates if a heat alarm is triggered.

The alarm_heat channel is of type alarm_heat and supports the Switch item and is in the Fire category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the NZW97. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED Indicator LED Indicator ON/OFF/Disabled
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: LED Indicator

LED Indicator ON/OFF/Disabled LED Indicator ON/OFF/Disabled
00==Plug On / LED On
01==Plug On / LED Off
02==LED Disabled Values in the range 0 to 2 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.