layout | title |
---|---|
documentation |
YRD120 - ZWave |
{% include base.html %}
This describes the Z-Wave device YRD120, manufactured by ASSA ABLOY with the thing type UID of yale_yrd120_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The YRD120 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
- Lock and unlock your door by entering your 4-8 digit pin code on the backlit, touchscreen keypad or through your Z-Wave smart home or alarm system app
- Store up to 100 unique pin codes to share with friends and family
- 100% key free with a 9V battery back-up to prevent lock-outs
- Installs on doors with just a screwdriver; fits 1-3/4 inch to 2-1/4 inch thick doors
The lock can be included in a Z-Wave Network from the touchscreen as follows:
- Touch the lock screen to activate
- Enter the master pin and press #
- Press 7, then #
- Press 1, then #
The lock will now be in inclusion mode. Alternatively, the lock can be included by pressing and holding the radio button until the unit beeps 2 times. Release the button and the unit will enter inclusion mode.
The lock can be excluded from a Z-Wave Network from the touchscreen as follows:
- Touch the lock screen to activate
- Enter the master pin and press #
- Press 7, then #
- Press 3, then #
The lock will now be in exclusion mode. Alternatively, the lock can be excluded by pressing and holding the radio button until the unit beeps 5 times. Release the button and the unit will enter exclusion mode.
The following table summarises the channels available for the YRD120 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Alarm Number [Deprecated] | alarm_number | alarm_number | Number | |
Alarm Raw | alarm_raw | alarm_raw | String | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides the raw alarm value.
The alarm_number
channel is of type alarm_number
and supports the Number
item. This is a read only channel so will only be updated following state changes from the device.
Note: This channel is marked as deprecated so should not be used.
Provides alarm parameters as json string.
The alarm_raw
channel is of type alarm_raw
and supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 6 configuration parameters available in the YRD120. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Audio Volume | Sets the volume level of the beeps and voice prompts |
2 | Auto Re-lock | When enabled, the unit will automatically re-lock |
3 | Re-lock time | Time after unlocking that the device will lock |
4 | Wrong Code Entry Limit | The number of invalid tries before the lock shuts down and sends an alarm |
7 | Shutdown Time | Number of times the device is locked out after the invalid retries are exceeded |
8 | Operating Mode | Sets if the unit operates normal, or disables the keypad and Z-Wave lock/unlock |
Lock Timeout | Sets the time after which the door will auto lock |
Sets the volume level of the beeps and voice prompts 1 = Silent
2 = Low
3 = High The following option values may be configured -:
Value | Description |
---|---|
1 | Silent |
2 | Low |
3 | High |
The manufacturer defined default value is 3
(High).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
When enabled, the unit will automatically re-lock 0 = Off
255 = On The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Time after unlocking that the device will lock
Values in the range 5 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The number of invalid tries before the lock shuts down and sends an alarm
Values in the range 1 to 7 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Number of times the device is locked out after the invalid retries are exceeded
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Sets if the unit operates normal, or disables the keypad and Z-Wave lock/unlock 0 = Normal
1 = Vacation Mode (User Codes Disabled)
2 = Privacy Mode (User Codes and Z-Wave Disabled) The following option values may be configured -:
Value | Description |
---|---|
0 | Normal |
1 | Vacation |
2 | Privacy |
The manufacturer defined default value is 0
(Normal).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The YRD120 supports 1 association group.
Alarm reports are sent out to all devices in the association group
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | Linked to BASIC |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.