documentation
ZEN21 - ZWave

{% include base.html %}

ZEN21 Paddle Switch

This describes the Z-Wave device ZEN21, manufactured by Zooz with the thing type UID of zooz_zen21_03_000. This version of the device is limited to firmware versions above 3.0

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZEN21 product image

The ZEN21 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave on.off switch with Scene control

Inclusion Information

Tap the upper paddle of the switch 3 times very quickly

Exclusion Information

Tap the lower paddle of the switch 3 times very quickly

Channels

The following table summarises the channels available for the ZEN21 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the ZEN21. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Paddle Control Reverse switch direction
2 LED Indicator Control LED Indicator Control
3 Auto Turn-off enable / disable Enable / Disable Auto Turn-off
4 Auto-Turn-off time Auto-Turn-off time
5 Auto Turn-on enable/disable Auto Turn-on enable/disable
6 Auto Turn-on timer Auto Turn-on timer
8 Status after Power Failure Status after Power Failure
9 Scene Control enable/disable Scene Control enable/disable
10 Paddle control enable/disable Paddle control enable/disable

Parameter 1: Paddle Control

Reverse switch direction

The following option values may be configured -:

Value Description
0 Top-ON, Bottom-OFF
1 Top-OFF, Bottom-ON
2 Any paddle turns light on/off

The manufacturer defined default value is 0 (Top-ON, Bottom-OFF).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: LED Indicator Control

LED Indicator Control

The following option values may be configured -:

Value Description
0 LED ON - Switch OFF
1 LED ON - Switch ON
2 LED always OFF
3 LED always ON

The manufacturer defined default value is 0 (LED ON - Switch OFF).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Auto Turn-off enable / disable

Enable / Disable Auto Turn-off Default disabled The following option values may be configured -:

Value Description
0 Timer disabled
1 Timer enabled

The manufacturer defined default value is 0 (Timer disabled).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Auto-Turn-off time

Auto-Turn-off time Default 60 minutes Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_4_4 and is of type INTEGER.

Parameter 5: Auto Turn-on enable/disable

Auto Turn-on enable/disable Default timer disabled The following option values may be configured -:

Value Description
0 Timer disabled
1 Timer enabled

The manufacturer defined default value is 0 (Timer disabled).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Auto Turn-on timer

Auto Turn-on timer Default 60 minutes Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_6_4 and is of type INTEGER.

Parameter 8: Status after Power Failure

Status after Power Failure

The following option values may be configured -:

Value Description
0 Forced to OFF
1 Forced to ON
2 Restore prior status (default)

The manufacturer defined default value is 2 (Restore prior status (default)).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Scene Control enable/disable

Scene Control enable/disable

The following option values may be configured -:

Value Description
0 Scene Control disabled
1 Scene Control enabled

The manufacturer defined default value is 1 (Scene Control enabled).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Paddle control enable/disable

Paddle control enable/disable

The following option values may be configured -:

Value Description
0 Local paddle control disabled
1 Local paddle control enabled

The manufacturer defined default value is 1 (Local paddle control enabled).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZEN21 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. This device will send BASIC REPORT to Group 1 when operated manually.

Association group 1 supports 1 node.

Group 2: Basic Report

This device will send BASIC SET to group 2 when operated manually.

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Documentation Links