layout | title |
---|---|
documentation |
ZEN21 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZEN21, manufactured by Zooz with the thing type UID of zooz_zen21_03_000
.
This version of the device is limited to firmware versions above 3.0
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN21 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Z-Wave on.off switch with Scene control
Tap the upper paddle of the switch 3 times very quickly
Tap the lower paddle of the switch 3 times very quickly
The following table summarises the channels available for the ZEN21 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
The following table provides a summary of the 9 configuration parameters available in the ZEN21. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Paddle Control | Reverse switch direction |
2 | LED Indicator Control | LED Indicator Control |
3 | Auto Turn-off enable / disable | Enable / Disable Auto Turn-off |
4 | Auto-Turn-off time | Auto-Turn-off time |
5 | Auto Turn-on enable/disable | Auto Turn-on enable/disable |
6 | Auto Turn-on timer | Auto Turn-on timer |
8 | Status after Power Failure | Status after Power Failure |
9 | Scene Control enable/disable | Scene Control enable/disable |
10 | Paddle control enable/disable | Paddle control enable/disable |
Reverse switch direction
The following option values may be configured -:
Value | Description |
---|---|
0 | Top-ON, Bottom-OFF |
1 | Top-OFF, Bottom-ON |
2 | Any paddle turns light on/off |
The manufacturer defined default value is 0
(Top-ON, Bottom-OFF).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
LED Indicator Control
The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON - Switch OFF |
1 | LED ON - Switch ON |
2 | LED always OFF |
3 | LED always ON |
The manufacturer defined default value is 0
(LED ON - Switch OFF).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Enable / Disable Auto Turn-off Default disabled The following option values may be configured -:
Value | Description |
---|---|
0 | Timer disabled |
1 | Timer enabled |
The manufacturer defined default value is 0
(Timer disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Auto-Turn-off time Default 60 minutes Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_4_4
and is of type INTEGER
.
Auto Turn-on enable/disable Default timer disabled The following option values may be configured -:
Value | Description |
---|---|
0 | Timer disabled |
1 | Timer enabled |
The manufacturer defined default value is 0
(Timer disabled).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Auto Turn-on timer Default 60 minutes Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_6_4
and is of type INTEGER
.
Status after Power Failure
The following option values may be configured -:
Value | Description |
---|---|
0 | Forced to OFF |
1 | Forced to ON |
2 | Restore prior status (default) |
The manufacturer defined default value is 2
(Restore prior status (default)).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Scene Control enable/disable
The following option values may be configured -:
Value | Description |
---|---|
0 | Scene Control disabled |
1 | Scene Control enabled |
The manufacturer defined default value is 1
(Scene Control enabled).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Paddle control enable/disable
The following option values may be configured -:
Value | Description |
---|---|
0 | Local paddle control disabled |
1 | Local paddle control enabled |
The manufacturer defined default value is 1
(Local paddle control enabled).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN21 supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. This device will send BASIC REPORT to Group 1 when operated manually.
Association group 1 supports 1 node.
This device will send BASIC SET to group 2 when operated manually.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.