This describes the Z-Wave device ZSE33, manufactured by Zooz with the thing type UID of zooz_zse33_00_000
.
The device is in the category of Siren, defining Siren used by Alarm systems.
The ZSE33 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
Smart Chime/Alarm
- Audio and visual notifications triggered by other Z-Wave devices or scheduled in your routine
- Choose from 10 different sounds for chime and siren modes
- Advanced configuration available
- Powerful long-lasting batteries
- Z-Wave Plus with improved 500 chip for faster and safer wireless communication
- Small size and quick installation
- Z-Wave Signal Frequency: 908.42 MHz
- Power: 2 CR123 batteries (included)
- Power Consumption: 2W
- Operating Temperature: 32 – 104 F
- Range: Up to 100 feet line of sight
- Installation and Use: Indoor only
- Dimensions: 2.7” x 1.2”
- Weight: 3 oz
Auto Inclusion:
- Put your Z-Wave controller in inclusion mode
- Carefully remove the cover from the device
- Remove the plastic pull-tab from the battery slot – the Chime will automatically enter inclusion mode for 20 seconds
- A new alarm siren / doorbell device will appear on your controller's device list
Manual Inclusion:
- Bring the Smart Chime within direct range of your controller
- Carefully remove the cover from the device
- Remove the plastic pull-tab from the battery slot. The LED indicator will blink slowly
- Put your Z-Wave controller in inclusion mode
- Press and release the Z-Wave button on the Smart Chime 3 TIMES quickly. The LED indicator will flash quickly
- A new alarm siren / doorbell device will appear on your controller's device list (if it connects as an on/off switch, you may need to change the device type manually. Contact us for instructions).
- Make sure the Smart Chime is powered on and located within direct range of your Z-Wave gateway controller
- Put your Z-Wave controller in exclusion mode
- Press and release the Z-Wave button 3 TIMES quickly. The LED indicator will flash quickly
- The Smart Chime should disappear from your controller's device list
If the first attempt is unsuccessful, please repeat the process following all steps carefully.
The following table summarises the channels available for the ZSE33 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 9 configuration parameters available in the ZSE33. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Siren Volume | 3 volume levels for the alarm siren sound. |
2 | Siren Alarm Duration | 5 modes to set the duration for siren alarm |
3 | Chime Sound Duration | Chime Sound Duration |
4 | Chime Volume | 3 volume levels for the doorbell sound. Set volume to low, medium, or high. |
5 | Siren Alarm Tone | 10 different tones for alarm siren |
6 | Chime Tone | 10 different tones for doorbell |
7 | Siren Alarm or Chime Mode | Siren Alarm or Chime Mode |
8 | LED Notifications for Siren Alarm | LED Notifications for Siren Alarm |
9 | LED Notifications for Chime | LED Notifications for Chime |
3 volume levels for the alarm siren sound. Values: 1 – low, 2 – medium, 3 – high (default) Values in the range 1 to 3 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
5 modes to set the duration for siren alarm 0 – alarm is off
1 – alarm goes off for 30 seconds
2 – alarm goes off for 60 seconds
3 – alarm goes off for 5 minutes
255 – alarm continues until battery drains
Values: 0, 1 – 3, 255; 1 – default setting. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Chime Sound Duration how many times the chime should repeat the doorbell sound once triggered by a BASIC_SET alarm command from a door sensor.
Values: 0 – chime is off, 1 – 254 (cycles); 255 – chime
sound continues until battery drains; 2 – default setting. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
3 volume levels for the doorbell sound. Set volume to low, medium, or high. Values: 1 – low, 2 – medium, 3 – high (default) Values in the range 1 to 3 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
10 different tones for alarm siren Values: 1-10; 10 – default setting. Values in the range 1 to 10 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
10 different tones for doorbell Values: 1-10; 4 – default setting. Values in the range 1 to 10 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Siren Alarm or Chime Mode Switch between Siren Alarm (configu-red by parameters 1, 2, 5, 8) and Chime / Doorbell (parameters 3, 4, 6, 9) modes.
Values: 1 – Siren Alarm enabled; 2 – Chime enabled (default). Values in the range 1 to 2 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
LED Notifications for Siren Alarm Enable or disable visual alarm for Siren mode. The LED will blink when triggered.
Values: 0 – LED disabled; 1 – LED enabled (default). Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
LED Notifications for Chime Enable or disable visual alarm for Chime mode. The LED will blink when triggered.
Values: 0 – LED disabled (default); 1 – LED enabled. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZSE33 supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Group 2 for status notifications to Z-Wave devices associated in this group.
Supported command classes: SWITCH_BINARY_REPORT
Association group 2 supports 5 nodes.
Group 3 for notifications to Z-Wave devices associated in this group.
Supported command classes: NOTIFICATION_REPORT
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_INDICATOR_V1 |