This describes the Z-Wave device ZME_05461, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme05461_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZME_05461 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The Z-Wave.Me Switch Flush Mountable is a wireless actuator able to switch two loads up to 1700 W each. Single clicks operate one load, double click operates the other load. The device is delivered as complete set with flush mountable insert, paddle and mounting frame compatible to the design of the switching series selected. The paddle of the device is used to control the device itself but can also be configured to activate scenes in a central IP gateway or controller. The device is able to meter the power consumed on the two loads if the attached load (in W) is configured correctly using a configuration parameter. The status of the switch is indicated on a dual color LED for test purposes and every status change is - if configured - reported to a central IP gateway or controller. The function of the local paddle can be configured as detached from the local operation. In this local control, different devices are controlled by Z-Wave while the local actuator is controlled by other devices using Z-Wave. This device is designed for a 3 wire system and needs a neutral wire in the wall box.
Triple click one of the buttons on the device will include the device.
The device is excluded by triple click to one of the buttons.
The following table summarises the channels available for the ZME_05461 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Switch 1 | switch_binary1 | switch_binary | Switch | Switch |
Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
Switch 2 | switch_binary2 | switch_binary | Switch | Switch |
Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary1
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh1
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts1
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Switch the power on and off.
The switch_binary2
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh2
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts2
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 15 configuration parameters available in the ZME_05461. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Set LED indication mode | |
2 | Automatically switch off first channel after | If not zero, automatically switch off after a user defined time |
3 | Function of RF off command on first channel | Function of RF off command on first channel |
4 | Switch on/off by holding buttons | Switch on/off by holding buttons |
5 | Restore switch state after power cycle | Restore switch state after power cycle |
11 | Invert buttons | Allows for exchanging ON and OFF. |
12 | Switch by buttons (first channel) | Switch by buttons (first channel) |
13 | Action on button single press or hold | Action on button single press or hold |
14 | Action on button double press or hold | Action on button double press or hold |
16 | What to do on button Down press (both) | What to do on button Down press (both) |
20 | Energy consumption for first channel | Energy consumption for first channel |
22 | Automatically switch off second channel after | If not zero, automatically switch off after a user defined time |
23 | Function of RF off command on second channel | Function of RF off command on second channel |
32 | Switch by buttons (second channel) | Switch by buttons (second channel) |
40 | Energy consumption for second channel | Energy consumption for second channel |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Show switch state |
2 | night light (inverted state) |
The manufacturer defined default value is 1
(Show switch state).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
If not zero, automatically switch off after a user defined time
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Function of RF off command on first channel Defines how to interpret RF first channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). The following option values may be configured -:
Value | Description |
---|---|
0 | Switch OFF |
1 | Ignore |
2 | Switch ON |
3 | Switch on if load is off else switch off |
The manufacturer defined default value is 0
(Switch OFF).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Switch on/off by holding buttons Defines if the switch should change it state to on/off if buttons are being hold. The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes (only for the first channel) |
2 | Yes (only for the second channel) |
3 | Yes (for both channels) |
The manufacturer defined default value is 1
(Yes (only for the first channel)).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Restore switch state after power cycle Defines if the switch should restore switch state to the last state prior to device power off (power cycle). The following option values may be configured -:
Value | Description |
---|---|
0 | No, turn off |
1 | Yes (only for the first channel) |
2 | Yes (only for the second channel) |
3 | Yes (for both channels) |
The manufacturer defined default value is 1
(Yes (only for the first channel)).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Allows for exchanging ON and OFF.
The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes |
The manufacturer defined default value is 0
(No).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Switch by buttons (first channel) If disabled, the local operations by buttons will not switch relay on first channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | By single press and hold |
2 | By double press and press-hold |
The manufacturer defined default value is 1
(By single press and hold).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Action on button single press or hold Defines which command should be sent on button single press or hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast. The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Switch On/Off only (send Basic Set) |
2 | Switch On/Off and Dim |
3 | Scene activation |
The manufacturer defined default value is 2
(Switch On/Off and Dim ).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Action on button double press or hold Defines which command should be sent on button double press or press-hold. Basic and Scene Activation commands are sent to Association group. Use Scene Controller Conf to set up Scene ID for Scene Activation. Switch All commands are sent broadcast.
If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Switch On/Off only (send Basic Set) |
2 | Switch On/Off and Dim |
3 | Scene activation |
The manufacturer defined default value is 2
(Switch On/Off and Dim ).
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
What to do on button Down press (both) Defines how to interpret button Down press. Depends on parameters 12 and 32 'Switch by buttons' parameter. If not Disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with Auto Off function. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch off |
1 | Switch On if load is Off, else switch Off |
2 | Switch on |
The manufacturer defined default value is 1
(Switch On if load is Off, else switch Off).
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Energy consumption for first channel Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W. The following option values may be configured, in addition to values in the range 0 to 1800 -:
Value | Description |
---|---|
0 | Disabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_20_2
and is of type INTEGER
.
If not zero, automatically switch off after a user defined time
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_22_2
and is of type INTEGER
.
Function of RF off command on second channel Defines how to interpret RF second channel Off command. Can be used in conjunction with Auto Off function: Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on - to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled). The following option values may be configured -:
Value | Description |
---|---|
0 | Switch OFF |
1 | Ignore |
2 | Switch ON |
3 | Switch on if load is off else switch off |
The manufacturer defined default value is 0
(Switch OFF).
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
Switch by buttons (second channel) If disabled, the local operations by buttons will not switch relay on second channel, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | By single press and hold |
2 | By double press and press-hold |
The manufacturer defined default value is 2
(By double press and press-hold).
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Energy consumption for second channel Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W. The following option values may be configured, in addition to values in the range 0 to 1800 -:
Value | Description |
---|---|
0 | Disabled |
The manufacturer defined default value is 0
(Disabled).
This parameter has the configuration ID config_40_2
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZME_05461 supports 3 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_METER_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_METER_V3 |