ZME_06437 - ZWave

{% include base.html %}

ZME_06437 Wall Plug Switch

This describes the Z-Wave device ZME_06437, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zme06437_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZME_06437 product image

The ZME_06437 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This is a plug switch that can be placed between a wall outlet for Schuko plugs (plug type F) and electric devices, plugged in by cord. It can switch all loads up to 3500 W. The device is IP 44 rated and can therefore be used both in dry environments as well as humid environments and outdoor. Switching is controlled wirelessly using Z-Wave or locally applying a button. A multi color LED indicates the switching status and the assignment of the colors to the switching status can be defined by the user. The device will report any change of the switching status to a central gateway regardless the origin of the switch (local or wireless). A built in virtual power meter will report the power consumption of the load attached. However the user must configure the assumed constant power draw of the load. The local button can control the local load but can also be used to control other functions in a Z-Wave network. The device is certified and tested against all important European Safety Regulations and fully complies with the Z-Wave Plus standard. The device supports secure communication and the firmware can be upgraded over the air (OTA)

Inclusion Information

Inclusion and Exclusion are confirmed by a triple click on the button

Exclusion Information

Inclusion and Exclusion are confirmed by a triple click on the button

Channels

The following table summarises the channels available for the ZME_06437 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the ZME_06437. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Set LED indication mode
2 Automatic switch off If not zero, automatically switch off after a user defined time
3 Function of RF off command Function of RF off command
5 Restore switch state after power cycle Restore switch state after power cycle
20 Energy consumption Energy consumption
21 Off Color
22 On Color
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Set LED indication mode

The following option values may be configured -:

Value Description
0 Disabled
1 Show switch state
2 Operated by Indicator Command Class

The manufacturer defined default value is 2 (Operated by Indicator Command Class).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Automatic switch off

If not zero, automatically switch off after a user defined time

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Function of RF off command

Function of RF off command Defines how to interpret RF Off-Command. Can be used in conjunction with Auto Off function: Ignore – to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on – to switch on the light on both ON and OFF paddle press on the remote and switch it off after some amount of time. Button OFF click will still work (if button operations are not disabled) The following option values may be configured -:

Value Description
0 Switch OFF
1 Ignore
2 Switch ON
3 Switch on if load is off else switch off

The manufacturer defined default value is 0 (Switch OFF).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 5: Restore switch state after power cycle

Restore switch state after power cycle Defines if the switch should restore switch state to the last state prior to device power off (power cycle). The following option values may be configured -:

Value Description
0 No, turn off
1 Yes (Default)

The manufacturer defined default value is 1 (Yes (Default)).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 20: Energy consumption

Energy consumption Specify the consumption of the load in watts, for the calculation of power consumption. Max load 1800 W. Values in the range 0 to 1800 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_20_2 and is of type INTEGER.

Parameter 21: Off Color

The following option values may be configured -:

Value Description
0 Off
1 Red
2 Green
3 Blue
4 Yellow

The manufacturer defined default value is 0 (Off).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 22: On Color

The following option values may be configured -:

Value Description
0 Off
1 Red
2 Green
3 Blue
4 Yellow

The manufacturer defined default value is 3 (Blue).

This parameter has the configuration ID config_22_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZME_06437 supports 2 association groups.

Group 1: Group 1

Association group 1 supports 5 nodes.

Group 2: Group 2

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V1

Documentation Links